Antithrombotic therapy following implantation of heart valve prostheses

被引:0
|
作者
Piper, C
Wiemer, M
Schulte, HD
Horstkotte, D
机构
[1] Ruhr Univ Bochum, Univ Klin, Kardiol Klin, Herzzent NRW, D-32545 Bad Oeynhausen, Germany
[2] Univ Dusseldorf, Chirurg Klin & Poliklin, Dusseldorf, Germany
来源
HERZ KREISLAUF | 1999年 / 31卷 / 04期
关键词
oral anticoagulation; International Normalized Ratio (INR); mechanical heart valve prostheses; bioprostheses; intracardiac thrombosis; cardioembolism;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Although the optimal intensity of oral anticoagulation has not been proved by prospective studies so far, general recommendation is an intensity equivalent to an international normalised ratio (INR) of 3.0-4.5 for patients following mechanical heart valve implantation. Recent investigations regarding the optimal management of oral anticoagulation in patients carrying prosthetic heart valves have shown a) a superiority of anticoagulation management by use of the INR instead of the prothrombin lime or the "Quick" levels, b) differences in the overall thrombogenicity of old as well as of more recently introduced prostheses, c) he necessity to adapt the anticoagulation intensity individually according to he patient related coagulability an one hand and cardiac morphology and physiology potentially predisposing to intracardiac thrombus formation on he other hand, and d) he potential benefit of patient education and self management of oral anticoagulation therapy as well as the individual self adjustment of anti-coagulation dosis may have.
引用
收藏
页码:145 / 149
页数:9
相关论文
共 50 条
  • [31] The search for optimal antithrombotic therapy in transcatheter aortic valve implantation: facts and uncertainties
    Ten Berg, Jurrien
    Rocca, Bianca
    Angiolillo, Dominick J.
    Hayashida, Kentaro
    EUROPEAN HEART JOURNAL, 2022, 43 (44) : 4616 - 4634
  • [32] Considerations in antithrombotic therapy among patients undergoing transcatheter aortic valve implantation
    Lynch, Donald R., Jr.
    Dantzler, David
    Robbins, Mark
    Zhao, David
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2013, 35 (04) : 476 - 482
  • [33] Considerations in antithrombotic therapy among patients undergoing transcatheter aortic valve implantation
    Donald R. Lynch
    David Dantzler
    Mark Robbins
    David Zhao
    Journal of Thrombosis and Thrombolysis, 2013, 35 : 476 - 482
  • [34] PREGNANCY AND HEART VALVE PROSTHESES
    LAROS, RK
    HAGE, ML
    HAYASHI, RH
    OBSTETRICS AND GYNECOLOGY, 1970, 35 (02): : 241 - &
  • [35] Cardiac resynchronization therapy implantation following transcatheter aortic valve implantation
    Osmancik, Pavel
    Stros, Petr
    Herman, Dalibor
    Kocka, Viktor
    Paskova, Eva
    EUROPACE, 2011, 13 (02): : 290 - 291
  • [36] HEART VALVE PROSTHESES AND PREGNANCY
    SOMMER, A
    ROMANO, JP
    GOUDARD, JR
    JOUVE, A
    SERMENT, H
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1973, 22 (03): : 183 - 187
  • [37] Antithrombotic therapy after heart valve surgery: contemporary practice in the UK
    Laskar, Nabila
    Bayliss, Christopher D.
    Kirmani, Bilal H.
    Chambers, John B.
    Maier, Rebecca
    Briffa, Norman P.
    Cartwright, Neil
    Kendall, Simon
    Shah, Benoy Nalin
    Akowuah, Enoch
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (05):
  • [38] Antiplatelet therapy following transcatheter aortic valve implantation
    Hassell, Mariella E. C. J.
    Hildick-Smith, David
    Durand, Eric
    Kikkert, Wouter J.
    Wiegerinck, Esther M. A.
    Stabile, Eugenio
    Ussia, Gian Paolo
    Sharma, Sumeet
    Baan, Jan, Jr.
    Eltchaninoff, Helene
    Rubino, Paolo
    Barbanti, Marco
    Tamburino, Corrado
    Poliacikova, Petra
    Blanchard, Didier
    Piek, Jan J.
    Delewi, Ronak
    HEART, 2015, 101 (14) : 1118 - 1125
  • [39] Antithrombotic Management for Transcatheter Aortic Valve Implantation
    Ya'Qoub, Lina
    Arnautovic, Jelena
    Sharkawi, Musa
    AlAasnag, Mirvat
    Jneid, Hani
    Elgendy, Islam Y.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [40] INVESTIGATIONS OF IRON AND FOLATE LEVELS IN SERUM AFTER IMPLANTATION OF HEART-VALVE PROSTHESES
    HEILMANN, E
    BENDER, F
    GULKER, H
    BONKE, J
    HERZ, 1979, 4 (03) : 298 - 302