A capacitive probe with shaped probe bias for ion flux measurements in depositing plasmas

被引:10
|
作者
Petcu, M. C. [1 ]
Bronneberg, A. C. [1 ]
Sarkar, A. [1 ]
Blauw, M. A. [2 ]
Creatore, M. [1 ]
van de Sanden, M. C. M. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Appl Phys, NL-5600 MB Eindhoven, Netherlands
[2] Holst Ctr, NL-5656 AE Eindhoven, Netherlands
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 11期
关键词
Langmuir probes; plasma materials processing;
D O I
10.1063/1.3020709
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The application of a pulse shaped biasing method implemented to a capacitive probe is described. This approach delivers an accurate and simple way to determine ion fluxes in diverse plasma mixtures. To prove the reliability of the method, the ion probe was used in a different configuration, namely, a planar Langmuir probe. In this configuration, the ion current was directly determined from the I-V characteristic and compared with the ion current measured with the pulse shaped ion probe. The results from both measurements are in excellent agreement. It is demonstrated that the capacitive probe is able to perform spatially resolved ion flux measurements under high deposition rate conditions (2-20 nm/s) in a remote expanding thermal plasma in Ar/NH(3)/SiH(4) mixture.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Monopole Antenna Probe for Density Measurements in Cold Plasmas
    王慧慧
    李弘
    王雨后
    李斌
    尤玮
    陈志鹏
    谢锦林
    刘万东
    Plasma Science and Technology, 2011, (02) : 197 - 200
  • [32] SIMPLE HEAT-FLUX DENSITY PROBE FOR INDUSTRIAL PLASMAS
    NUTSCH, G
    ROTHER, W
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (02) : 135 - 139
  • [33] ON THE POSSIBILITY OF USING A HEAVY ION BEAM PROBE FOR LOCAL POLOIDAL FLUX MEASUREMENTS IN A TOKAMAK
    Weisen, H.
    Melnikov, A. V.
    Perfilov, S.
    Lysenko, S.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (02) : 418 - 426
  • [34] Ion flux measurements with the improved collector probe system at the TEXTOR-94 tokamak
    Larsson, D
    Rubel, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (07): : 2671 - 2674
  • [35] ELIMINATING THE INFLUENCE OF THE ION CURRENT ON PROBE MEASUREMENTS OF THE ELECTRON-ENERGY DISTRIBUTION FUNCTION IN PLASMAS
    KOLOKOLOV, NB
    KUDRYAVTSEV, AA
    KHROMOV, NA
    HIGH TEMPERATURE, 1991, 29 (03) : 336 - 339
  • [36] Triple Probe Measurements in Transient Plasma of Pulsed Capacitive Discharge
    Qayyum, A.
    Ahmad, S.
    Ahmad, N.
    Deeba, Farah
    Hussain, S.
    JOURNAL OF FUSION ENERGY, 2015, 34 (02) : 405 - 410
  • [37] Triple Probe Measurements in Transient Plasma of Pulsed Capacitive Discharge
    A. Qayyum
    S. Ahmad
    N. Ahmad
    Farah Deeba
    S. Hussain
    Journal of Fusion Energy, 2015, 34 : 405 - 410
  • [38] Effect of Bias Frequency on the Accuracy of Floating Probe Measurements
    Choi, Myung-Sun
    Lee, Seok-Hwan
    Kim, Gon-Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (05) : 1841 - 1848
  • [39] A modified Katsumata probe-Ion sensitive probe for measurement in non-magnetized plasmas
    Cada, M.
    Hubicka, Z.
    Adamek, P.
    Olejnicek, J.
    Kment, S.
    Adamek, J.
    Stoeckel, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07):
  • [40] Investigation of Tin and Chromium Metal Plasmas by Langmuir Probe Measurements
    Burm, K. T. A. L.
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2012, 32 (02) : 393 - 399