4D velocity measurements in intracranial aneurysms using 3T phase contrast MRI angiography

被引:0
|
作者
van Ooij, P. [1 ]
Schneiders, J. J. [1 ]
VanBavel, E. [1 ]
Majoie, C. B. [1 ]
Nederveen, A. J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, NL-1105 AZ Amsterdam, Netherlands
关键词
intracranial aneurysms; phase contrast MR imaging; k-t BLAST; blood flow velocity; kinetic energy density; K-T SENSE; FLOW; BLAST;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To obtain hemodynamic descriptors of intracranial aneurismal flow, phase contrast MRI was performed on two aneurysms. To compare accelerated with non-accelerated scans, an acceleration technique called k-t BLAST was applied to one of the scans and compared with the non-accelerated scan. Results showed that velocity magnitude, directions and vorticity could be visualized accurately in non-accelerated measurements, but the accelerated scan showed a significant deviation from the non-accelerated scan.
引用
收藏
页码:617 / 620
页数:4
相关论文
共 50 条
  • [31] Aortic 4D flow: quantifying the effects of contrast and field strength at 1.5 T, 3T and 7T
    Aaron T Hess
    Malenka M Bissell
    Andrew Lewis
    Ntobeko A Ntusi
    Jane M Francis
    Saul G Myerson
    Stefan Neubauer
    Matthew D Robson
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [32] Accelerated 4D phase contrast MRI in skeletal muscle contraction
    Mazzoli, Valentina
    Gottwald, Lukas M.
    Peper, Eva S.
    Froeling, Martijn
    Coolen, Bram F.
    Verdonschot, Nico
    Sprengers, Andre M.
    van Ooij, Pim
    Strijkers, Gustav J.
    Nederveen, Aart J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1799 - 1811
  • [33] MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils
    Majoie, CBLM
    Sprengers, ME
    van Rooij, WJJ
    Lavini, C
    Sluzewski, M
    van Rijn, JC
    den Heeten, GJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (06) : 1349 - 1356
  • [34] CONTRAST MATERIAL-ENHANCED MR ANGIOGRAPHY FOR INTRACRANIAL ANEURYSMS WITH 3D TIME-OF-FLIGHT AND 3D PHASE-CONTRAST TECHNIQUES
    CHUNG, WC
    LISTERUD, J
    ATLAS, SW
    RADIOLOGY, 1992, 185 : 121 - 121
  • [35] Intracranial aneurysm stiffness assessment using 4D Flow MRI
    Koizumi, Satoshi
    Kin, Taichi
    Sekine, Tetsuro
    Kiyofuji, Satoshi
    Umekawa, Motoyuki
    Saito, Nobuhito
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (06)
  • [36] Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations
    Suzuki, Yuriko
    Fujima, Noriyuki
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 294 - 309
  • [37] How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study
    Brina, O.
    Bouillot, P.
    Reymond, P.
    Luthman, A. S.
    Santarosa, C.
    Fahrat, M.
    Lovblad, K. O.
    Machi, P.
    Delattre, B. M. A.
    Pereira, V. M.
    Vargas, M., I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (12) : 2117 - 2123
  • [38] Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA
    Birgitta Ramgren
    Roger Siemund
    Mats Cronqvist
    Per Undrén
    Ola G. Nilsson
    Stig Holtås
    Elna-Marie Larsson
    Neuroradiology, 2008, 50
  • [39] 4D Flow MRI in Patients With Intracranial Aneurysms: a Comparative Analysis Between Evolving vs. Stable Aneurysms
    Nael, Kambiz
    Shogan, Tamer
    Fung, Maggie
    Deleacy, Reade
    Fifi, Johanna
    Mocco, J.
    STROKE, 2018, 49
  • [40] Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series
    Pierot, Laurent
    Portefaix, Christophe
    Boulin, Anne
    Gauvrit, Jean-Yves
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2255 - 2263