An ultra-high-resolution study of the interstellar medium towards Orion

被引:32
|
作者
Price, RJ [1 ]
Crawford, IA [1 ]
Barlow, MJ [1 ]
Howarth, ID [1 ]
机构
[1] UCL, Dept Phys & Astron, London WC1E 6BT, England
关键词
line : profiles; ISM : atoms;
D O I
10.1046/j.1365-8711.2001.04893.x
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report ultra-high-resolution observations (R approximate to 9 x 10(5)) of Na I, Ca II, K I, CH and CH+ for interstellar sightlines towards 12 bright stars in Orion. These data enable the detection of many more absorption components than previously recognized, providing a more accurate perspective on the absorbing medium. This is especially so for the line of sight to the Orion nebula, a region not previously studied at very high resolution. Model fits have been constructed for the absorption-line profiles, providing estimates for the column density, velocity dispersion and central velocity for each constituent velocity component. A comparison between the absorption occurring in sightlines with small angular separations has been used, along with comparisons with other studies, to estimate the line-of-sight velocity structures. Comparisons with earlier studies have also revealed temporal variability in the absorption-line profile of zeta Ori, highlighting the presence of small-scale spatial structure in the interstellar medium on scales of approximate to 10 au. where absorption from both Na-0 and K-0 is observed for a particular cloud, a comparison of the velocity dispersions measured for each of these species provides rigorous limits on both the kinetic temperature and turbulent velocity prevailing in each cloud. Our results indicate the turbulent motions to be subsonic in each case. Na-0/Ca+ abundance ratios are derived for individual clouds, providing an indication of their physical state.
引用
收藏
页码:555 / 582
页数:28
相关论文
共 50 条
  • [21] From FWI to ultra-high-resolution imaging
    Espin I.
    Salaun N.
    Jiang H.
    Reinier M.
    Leading Edge, 2023, 42 (01): : 16 - 23
  • [22] Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study
    Yoshioka, Kunihiro
    Tanaka, Ryoichi
    Takagi, Hidenobu
    Ueyama, Yuta
    Kikuchi, Kei
    Chiba, Takuya
    Arakita, Kazumasa
    Schuijf, Joanne D.
    Saito, Yasuo
    NEURORADIOLOGY, 2018, 60 (01) : 109 - 115
  • [23] Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study
    Kunihiro Yoshioka
    Ryoichi Tanaka
    Hidenobu Takagi
    Yuta Ueyama
    Kei Kikuchi
    Takuya Chiba
    Kazumasa Arakita
    Joanne D. Schuijf
    Yasuo Saito
    Neuroradiology, 2018, 60 : 109 - 115
  • [24] Relationship between Resolution and Impression for Ultra-high-resolution Images
    Shishikui, Yoshiaki
    Sawahata, Yasuhito
    2017 IEEE INTERNATIONAL SYMPOSIUM ON BROADBAND MULTIMEDIA SYSTEMS AND BROADCASTING (BMSB), 2017, : 195 - 198
  • [25] 1ST RESULTS FROM THE UHRF - ULTRA-HIGH-RESOLUTION OBSERVATIONS OF INTERSTELLAR CH, CH+ AND CN TOWARDS ZETA-OPHIUCHI
    CRAWFORD, IA
    BARLOW, MJ
    DIEGO, F
    SPYROMILIO, J
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1994, 266 (04) : 903 - 909
  • [26] Physical evaluation of an ultra-high-resolution CT scanner
    Luuk J. Oostveen
    Kirsten L. Boedeker
    Monique Brink
    Mathias Prokop
    Frank de Lange
    Ioannis Sechopoulos
    European Radiology, 2020, 30 : 2552 - 2560
  • [27] ULTRA-HIGH-RESOLUTION INTENSITY STATISTICS OF A SCINTILLATING SOURCE
    Johnson, M. D.
    Gwinn, C. R.
    ASTROPHYSICAL JOURNAL, 2012, 755 (02):
  • [28] Ultra-high-resolution structures of a bridged bimetallohydrolase.
    Desmarais, W
    Ringe, D
    Petsko, G
    BIOCHEMISTRY, 2001, 40 (29) : 8632 - 8633
  • [29] Design of an ultra-high-resolution 300 kV microscope
    Bakker, H
    Bleeker, A
    Mul, P
    ELECTRON MICROSCOPY AND ANALYSIS 1995, 1995, 147 : 273 - 276
  • [30] Physical evaluation of an ultra-high-resolution CT scanner
    Oostveen, Luuk J.
    Boedeker, Kirsten L.
    Brink, Monique
    Prokop, Mathias
    de Lange, Frank
    Sechopoulos, Ioannis
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2552 - 2560