Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds

被引:10
|
作者
Rüb, N
Doernberger, V
Smits, K
Schweitzer, S
Mewis, C
Kettering, K
Kuehlkamp, V
机构
[1] Univ Tubingen, Dept Cardiol, D-72076 Tubingen, Germany
[2] Bakken Res Ctr, Maastricht, Netherlands
来源
关键词
implantable cardioverter defibrillator; defibrillation threshold; leads; lead position;
D O I
10.1111/j.1540-8159.2004.00439.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transvenous unipolar active can defibrillation systems have proven to be effective in treating ventricular tachyarrhythmias. However, a further reduction of ventricular defibrillation thresholds (V-DFT) would increase the longevity, reduce the size of pulse generators, and help to avoid additional leads in patients with inacceptable high V-DFTs. In a finite difference computer model, the extension of the right ventricular (RV) defibrillation coil into the low right atrium led to a 40% reduction of unipolar V-DFT To evaluate this finding, we conducted a prospective, randomized study in 11 patients receiving on ICD. Extension of the RV electrode was simulated by adding a second coil placed in the low right atrium with the some polarity. Using a binary search protocol, V-DFT was determined with and without the additional electrode in each patient. Total shock impedance was significantly lower in the two coil (low RA) configuration, compared to the single coil (RV) configuration. Corresponding values were 49.9 +/- 6.7 Ohm and 61.1 +/- 9.3 Ohm, respectively (P < 0.01, paired t-test). However, there was no reduction, but even a nonsignificant increase in V-DFTs. Mean V-DFT in the RV configuration was 12.0 +/- 5.6 J and 16.3 +/- 7.8 J in the low RA configuration (P = 0.09, paired t-test). Despite a reduction in total impedance, the addition of a defibrillation coil in the low right atrium does not reduce ventricular defibrillation thresholds.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 50 条
  • [21] Defibrillation thresholds and changes in ventricular fibrillation morphology
    Kavanagh, KM
    Guerrero, PA
    Witkowski, FX
    Jugdutt, BI
    Jones, KL
    CIRCULATION, 1996, 94 (08) : 4183 - 4183
  • [22] Ventricular fibrillation and defibrillation thresholds in sheep and dogs
    Wan, YK
    Holley, L
    Einstein, R
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR AND INTEGRATIVE PHYSIOLOGY, 1998, 121 (01): : 77 - 82
  • [23] The effect of a passive coronary sinus defibrillation lead on the ventricular defibrillation threshold
    Benser, ME
    Girouard, SD
    Killingsworth, CR
    Walcott, GP
    Ideker, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 122A - 123A
  • [24] Nonthoracotomy implantation of cardioverter defibrillators: Preliminary experience with a defibrillation lead placed at the right ventricular outflow tract
    Tang, ASL
    Hendry, P
    Goldstein, W
    Green, MS
    Luce, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (06): : 960 - 964
  • [25] Right ventricular perforation with an ICD defibrillation lead managed by surgical revision and epicardial leads -: Case reports
    Krivan, Lubomir
    Kozak, Milan
    Vlasinova, Jitka
    Sepsi, Milan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (01): : 3 - 6
  • [26] AN ELECTRODE SYSTEM FOR CLOSED CHEST VENTRICULAR DEFIBRILLATION
    OBEL, IWP
    POLUTA, M
    JARDINE, R
    SMITS, K
    BOURGEOIS, I
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 723 - 723
  • [27] Optimal characteristics of an endocardial lead for ventricular defibrillation
    Altamura, G
    DeRosa, A
    DeSeta, F
    Santini, M
    PACEMAKER LEADS 1997, 1997, : 541 - 545
  • [28] Right ventricular outflow tract placement of defibrillation leads: Five year experience
    Giudici, MC
    Barold, SS
    Paul, DL
    Schrumpf, PE
    Van Why, KJ
    Orias, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (04): : 443 - 446
  • [29] Right Ventricular Insertions Play an Important Role in the Reinitiation of Ventricular Fibrillation Following Failed Defibrillation Shocks
    Iijima, Kenichi
    Zhang, Hanyu
    Huang, Jian
    Walcott, Gregory P.
    Rogers, Jack M.
    CIRCULATION, 2017, 136
  • [30] PROCAINAMIDE DOES NOT AFFECT VENTRICULAR DEFIBRILLATION IN DOGS
    ECHT, DS
    COXE, DR
    BLACK, JN
    SEWELL, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A166 - A166