Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing

被引:30
|
作者
Lima-Oliveira, Gabriel [1 ,2 ,3 ,4 ]
Lippi, Giuseppe [5 ]
Salvagno, Gian Luca [1 ]
Montagnana, Martina [1 ]
Picheth, Geraldo [2 ]
Guidi, Gian Cesare [1 ,2 ]
机构
[1] Univ Verona, Lab Clin Biochem, Dept Life & Reprod Sci, I-37100 Verona, Italy
[2] Univ Fed Parana, Dept Med Pathol, Postgrad Program Pharmaceut Sci, BR-80060000 Curitiba, Parana, Brazil
[3] MERCOSUL Sect Comm Clin Anal & Vitro Diagnost CSM, Rio De Janeiro, Brazil
[4] Brazilian Soc Clin Anal Sao Paulo State, Sao Paulo, Brazil
[5] Acad Hosp Parma, Dept Pathol & Lab Med, Clin Chem & Hematol Lab, Parma, Italy
关键词
blood collection; plasma samples; preanalytical variability; vacuum tubes; validation process; BIOLOGICAL VARIATION; CLINICAL-CHEMISTRY; QUALITY; COLLECTION; STASIS;
D O I
10.1097/MBC.0b013e32835b72ea
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sometimes in-vitro diagnostic devices (e. g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P<0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices. Blood Coagul Fibrinolysis 24:252-255 (C) 2013 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 27 条
  • [21] Management of preanalytical phase for routine hematological testing: is the pneumatic tube system a source of laboratory variability or an important facility tool?
    Lima-Oliveira, G.
    Lippi, G.
    Salvagno, G. L.
    Dima, F.
    Brocco, G.
    Picheth, G.
    Guidi, G. C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (04) : E37 - E40
  • [22] Assessing Glucose Stability: A Comparison of Citrate/NaF, NaF, and Gel Separator Vacuum Tubes in Routine Medical Laboratory Practice
    Kosova, S.
    CLINICAL CHEMISTRY, 2024, 70
  • [23] The determination of euglobulin clot lysis time reference intervals in Beckton Dickinson and Kima 3.2% sodium citrate coagulation tubes
    Kuktic, Ivona
    Pasalic, Ante
    Cancarevic, Ognjen
    Galic, Edvard
    Saracevic, Andrea
    Biljak, Vanja Radisic
    BLOOD COAGULATION & FIBRINOLYSIS, 2025, 36 (01) : 14 - 17
  • [24] Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-mL (pediatric) tubes
    Chuang, J
    Sadler, MA
    Witt, DM
    CHEST, 2004, 126 (04) : 1262 - 1266
  • [25] Brand of dipotassium EDTA vacuum tube as a new source of pre-analytical variability in routine haematology testing
    Lima-Oliveira, G.
    Lippi, G.
    Salvagno, G. L.
    Montagnana, M.
    Poli, G.
    Solero, G. P.
    Picheth, G.
    Guidi, G. C.
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2013, 70 (01) : 6 - 9
  • [26] Development and implementation of an expert rule set for automated reflex testing and validation of routine coagulation tests in a large pathology network
    Mohammed, Soma
    Priebbenow, Violeta Ule
    Pasalic, Leonardo
    Favaloro, Emmanuel J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 (05) : 642 - 649
  • [27] Evaluation (Correlation/Validation) of 0.109M BD Vacutainer Plus Plastic (2.7 mL) and 0.105M BD Vacutainer Glass Sodium Citrate Tubes (4.5 mL) for PT, APTT, and Fibrinogen Using Diagnostic Stago STA
    Patel, Sahil
    Jhala, Darshana
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 149 : S31 - S32