Tri-axial accelerometer analysis techniques for evaluating functional use of the extremities

被引:31
|
作者
Hurd, Wendy J. [1 ]
Morrow, Melissa M. [1 ]
Kaufman, Kenton R. [1 ]
机构
[1] Mayo Clin, Div Orthoped Res, Dept Orthoped Surg, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
Inertial sensor system; Measurement; Evaluation; TIME-SERIES ANALYSIS; PHYSICAL-ACTIVITY; GAIT; ENTROPY;
D O I
10.1016/j.jelekin.2013.03.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Activity monitors provide an objective mechanism for evaluating patient function. It is unclear what similarities or unique information may be yielded using different analyses. Fifteen patients scheduled to undergo shoulder arthroplasty and fifteen matched control subjects wore tri-axial accelerometer activity monitors bilaterally at the lower (wrist) and upper (biceps) arm for 3 days. Measures of central tendency, variance, sample entropy, and asymmetry were calculated. A novel technique to evaluate time distribution of activity intensity was also performed. Within both groups there was a difference in central tendency and variance when comparing dominant and non-dominant limbs for both the lower (Controls: Mean Activity, P < 0.001; Max Activity, P < 0.001; Patients: Mean Activity, P = 0.044; Max Activity, P = 0.009) and upper (Controls: Mean Activity, P < 0.001; Max Activity, P = 0.046; Patients: Mean Activity, P = 0.002; Max Activity, P = 0.049) arm. Within group differences were also present for lower arm entropy in both groups (Controls, P < 0.001; Patients P = 0.041), and at the upper arm for patients (P = 0.003). There were differences between groups for the asymmetry index for both the lower (P = 0.033) and upper arm (P = 0.005), and maximum activity level of the lower arm (P = 0.05). Between group differences were present for time distribution of activity intensity, as the involved upper arm of patients was inactive for a greater time than controls (P = 0.013). These results highlight unique information provided by multiple analysis methods, and include a novel approach of evaluating the distribution of time spent across variable intensity activities. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:924 / 929
页数:6
相关论文
共 50 条
  • [31] Dry electromyography sensor with tri-axial accelerometer wireless for movement assessments
    de Oliveira, Frederico Amaral
    Pimenta, Tales Cleber
    Castro, Roberto, Jr.
    2013 ISSNIP BIOSIGNALS AND BIOROBOTICS CONFERENCE (BRC), 2013, : 17 - 21
  • [32] TRI-AXIAL ACCELEROMETER USAGE IN PEDAGOGICAL PROCESS IN CZECH ELEMENTARY SCHOOL
    Vespalec, Tomas
    Pavlik, Jindrich
    7TH INTERNATIONAL SCIENTIFIC CONFERENCE ON KINESIOLOGY: FUNDAMENTAL AND APPLIED KINESIOLOGY - STEPS FORWARD, 2014, : 314 - 317
  • [33] Activity classification using a single chest mounted tri-axial accelerometer
    Godfrey, A.
    Bourke, A. K.
    Olaighin, G. M.
    van de Ven, P.
    Nelson, J.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (09) : 1127 - 1135
  • [34] Discrimination of biting and chewing behaviour in sheep using a tri-axial accelerometer
    Alvarenga, F. A. P.
    Borges, I.
    Oddy, V. H.
    Dobos, R. C.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2020, 168
  • [35] Measurement of the Delivery Environment Using Demo Parcel with Tri-axial Accelerometer
    Kwon, Ohyeon
    Won, Jong-Un
    2019 34TH INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS AND COMMUNICATIONS (ITC-CSCC 2019), 2019, : 445 - 448
  • [36] STEP COUNT VALIDATION OF A TRI-AXIAL ACCELEROMETER DURING WALKING AND JOGGING
    Fortune, Emma
    Lugade, Vipul
    Morrow, Melissa
    Kaufman, Kenton
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1065 - 1066
  • [37] A Miniature Bluetooth Tri-axial Accelerometer Unit Suitable for EMA Applications
    Nguyen, L. T.
    Haritos, N.
    PROCEEDINGS OF THE 25TH AUSTRALASIAN CONFERENCE ON MECHANICS OF STRUCTURES AND MATERIALS (ACMSM25), 2020, 37 : 865 - 877
  • [38] Fall Monitoring Device for Old People based on Tri-Axial Accelerometer
    Luo, Jing
    Zhong, Bocheng
    Lv, Dinghao
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2015, 6 (05) : 34 - 39
  • [39] Estimation of Gait Independence Using a Tri-Axial Accelerometer in Stroke Patients
    Kijima, Yoshifumi
    Kiyama, Ryoji
    Sekine, Masaki
    Tamura, Toshiyo
    Fujimoto, Toshiro
    Maeda, Tetsuo
    Ohshige, Tadasu
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2018, 26 (01) : 61 - 67
  • [40] Effect of noise on accelerometer vector measurement in an ideal tri-axial system
    De Freitas, J. M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (04)