Ten-year results of the Press Fit Condylar Sigma total knee replacement

被引:24
|
作者
Arthur, C. H. C. [1 ]
Wood, A. M. [1 ]
Keenan, A. C. M. [1 ]
Clayton, R. A. E. [1 ]
Walmsley, P. [1 ]
Brenkel, I. [1 ]
机构
[1] Victoria Hosp Kirkcaldy, NHS Fife, Kirkcaldy KY2 5AY, England
来源
BONE & JOINT JOURNAL | 2013年 / 95B卷 / 02期
关键词
SURVIVAL ANALYSIS; FOLLOW-UP; ARTHROPLASTY; PROSTHESIS;
D O I
10.1302/0301-620X.95B2.29695
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report ten-year clinical and radiological follow-up data for the Sigma Press Fit Condylar total knee replacement system (Sigma PFC TKR). Between October 1998 and October 1999 a total of 235 consecutive PFC Sigma TKRs were carried out in 203 patients. Patients were seen at a specialist nurse-led clinic seven to ten days before admission and at six and 18 months, three, five and eight to ten years after surgery. Data were recorded prospectively at each clinic visit. Radiographs were obtained at the five- and eight- to ten-year follow-up appointments. Of the 203 patients, 147 (171 knees) were alive at ten years and 12 were lost to follow-up. A total of eight knees (3.4%) were revised, five for infection and three to change the polyethylene insert. The survival at ten years with an endpoint of revision for any reason was 95.9%, and with an endpoint of revision for aseptic failure was 98.7%. The mean American Knee Society Score (AKSS) was 79 (10 to 99) at eight to ten years, compared with 31 (2 to 62) pre-operatively. Of 109 knee with radiographs reviewed, 47 knees had radiolucent lines but none showed evidence of loosening.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 50 条
  • [31] Ten-year survival of cemented total knee replacement in patients aged less than 55 years
    Keenan, A. C. M.
    Wood, A. M.
    Arthur, C. A.
    Jenkins, P. J.
    Brenkel, I. J.
    Walmsley, P. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 928 - 931
  • [32] Press-Fit Condylar design total knee arthroplasty - Fourteen to seventeen-year follow-up
    Rodricks, David J.
    Patil, Shantanu
    Pulido, Pamela
    Colwell, Clifford W., Jr.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01): : 89 - 95
  • [33] FAILURE OF TOTAL CONDYLAR KNEE REPLACEMENT
    SCHNEIDER, R
    ABENAVOLI, AM
    SOUDRY, M
    INSALL, J
    RADIOLOGY, 1984, 152 (02) : 309 - 315
  • [34] Total condylar knee replacement -: A 20-year followup study
    Rodriguez, JA
    Bhende, H
    Ranawat, CS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 10 - 17
  • [35] TOTAL KNEE REPLACEMENT - THE BLOEMFONTEIN EXPERIENCE WITH THE TOTAL CONDYLAR KNEE
    CILLIERS, HJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 503 - 503
  • [36] Ten-year life expectancy after primary total hip replacement
    Ramiah, R. D.
    Ashmore, A. M.
    Whitley, E.
    Bannister, G. C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (10): : 1299 - 1302
  • [37] Press-Fit Condylar total knee arthroplasty - 5- to 9-year follow-up evaluation
    Martin, SD
    McManus, JL
    Scott, RD
    Thornhill, TS
    JOURNAL OF ARTHROPLASTY, 1997, 12 (06): : 603 - 614
  • [38] Survivorship analysis at 15 years of cemented press-fit condylar total knee arthroplasty
    Attar, Fahad G.
    Khaw, Fli-Meng
    Kirk, Lorna M. G.
    Gregg, P. J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 344 - 349
  • [39] The Ten-Year Substation Replacement Program
    Parra, Giovanni
    Saldana, Mark
    Singh, Jimmy
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2018, 24 (05) : 28 - 42
  • [40] Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements
    Fehring, TK
    Murphy, JA
    Hayes, TD
    Roberts, DW
    Pomeroy, DL
    Griffin, WL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 40 - 50