Performance of computer-aided diagnosis for detection of lacunar infarcts on brain MR images: ROC analysis of radiologists' detection

被引:0
|
作者
Uchiyama, Y. [1 ]
Yokoyama, R. [1 ]
Asano, T. [2 ]
Kato, H. [2 ]
Yamakawa, H. [3 ,5 ]
Ando, H. [4 ]
Yamakawa, H. [3 ,5 ]
Hara, T. [1 ]
Iwama, T. [3 ]
Hoshi, H. [2 ]
Fujita, H. [1 ]
机构
[1] Gifu Univ, Grad Scholl Med, Dept Intelligent Image Informat, Gifu, Japan
[2] Gifu Univ, Grad Scholl Med, Dept Radiol, Gifu, Japan
[3] Gifu Univ, Grad Scholl Med, Dept Neurosurg, Gifu, Japan
[4] Gifu Municipal Hosp, Dept Neurosurg, Gifu, Japan
[5] Chuno Kousei Hosp, Dept Emergency & Crit Care Med, Gifu, Japan
关键词
Lacunar infarcts; Magnetic resonance imaging (MRI); Computer-aided diagnosis (CAD); Receiver operating characteristic (ROC) analysis;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The detection and management of asymptomatic lacunar infarcts on magnetic resonance (MR) images are important tasks for radiologists to ensure the prevention of sever cerebral infarctions. However, accurate identification of lacunar infarcts is a difficult. Therefore, we developed a computer-aided diagnosis (CAD) scheme for detection of lacunar infarcts. The purpose of this study was to evaluate radiologists' performance in detection of lacunar infarcts without and with use of CAD scheme. 30 T1- and 30 T2- weighted images obtained from 30 patients were used for an observer study, which were consisted of 15 cases with a single lacunar infarct and 15 cases without any lacunar infarct. Six radiologists participated in the observer study. They interpreted lacunar infarcts first without and then with use of the scheme. For all six observers, average area under the receiver operating characteristic curve value was increased from 0.920 to 0.965 when they used the computer output. This CAD scheme might have the potential to improve the accuracy of radiologists' performance in the detection of lacunar infarcts on MR images.
引用
收藏
页码:S395 / S397
页数:3
相关论文
共 50 条
  • [31] Automatic Computer-Aided Detection of Multiple Sclerosis (MS) Lesions on MR Images
    Eksi, Ziya
    Ozcan, Muhammed Emin
    Aralasmak, Ayse
    Dandil, Emre
    Cakiroglu, Murat
    2015 19TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2015,
  • [32] Computer-aided detection in clinical environment: benefits and challenges for radiologists
    Krupinski, EA
    RADIOLOGY, 2004, 231 (01) : 7 - 9
  • [33] Performance of mammographic computer-aided detection
    Collins, M
    Mitchell, R
    Worrell, S
    Hoffmeister, JW
    Bauer, K
    Rogers, SK
    Kabrisky, M
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 1041 - 1041
  • [34] Automated discovery of meniscal tears on MR imaging: A novel, high-performance, computer-aided detection application for radiologists
    Ramakrishna, Bharath
    Safdar, Nabile
    Siddiqui, Khan
    Kim, Woojin
    Liu, Weimin
    Saiprasad, Ganesh
    Chang, Chein-, I
    Siegel, Eliot
    MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915
  • [35] Computer-aided diagnosis system of systems for neonatal and infantile brain using MR images
    Graduate School of Engineering, University of Hyogo, Japan
    不详
    不详
    不详
    IEEE Int. Conf. Syst. Syst. Eng., SoSE, 2008,
  • [36] Computer-aided Diagnosis System of Systems for Neonatal and Infantile Brain Using MR images
    Kobashi, Syoji
    Fujimoto, Yuko
    Oshiba, Takuma
    Ogawa, Masayo
    Ando, Kumiko
    Ishikura, Reiichi
    Imawaki, Seturo
    Hirota, Shozo
    Hata, Yutaka
    2008 IEEE INTERNATIONAL CONFERENCE ON SYSTEM OF SYSTEMS ENGINEERING (SOSE), 2008, : 142 - 147
  • [37] Computer-aided detection in mammography: An assessment of performance on current and prior images
    Zheng, B
    Shah, R
    Wallace, L
    Hakim, C
    Ganott, MA
    Gur, D
    ACADEMIC RADIOLOGY, 2002, 9 (11) : 1245 - 1250
  • [38] Computer-aided diagnosis scheme for detection of unruptured intracranial aneurysms in MR angiography
    Uchiyama, Y.
    Ando, H.
    Yokoyama, R.
    Hara, T.
    Fujita, H.
    Iwama, T.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3031 - 3034
  • [39] Computer-aided diagnosis to distinguish benign from malignant solitary pulmonary nodules on radiographs: ROC analysis of radiologists'
    Shiraishi, J
    Abe, H
    Engelmann, R
    Aoyama, M
    MacMahon, H
    Doi, K
    RADIOLOGY, 2003, 227 (02) : 469 - 474
  • [40] Heart sound analysis for symptom detection and computer-aided diagnosis
    Reed, TR
    Reed, NE
    Fritzson, P
    SIMULATION MODELLING PRACTICE AND THEORY, 2004, 12 (02) : 129 - 146