Evaluation of mineral content of dentin prepared by erbium, chromium:yttrium scandium gallium garnet laser

被引:24
|
作者
Secilmis, Asli [1 ]
Altintas, Subutay Han [2 ]
Usumez, Aslihan [3 ]
Berk, Gizem [4 ]
机构
[1] Selcuk Univ, Fac Dent, Dept Prosthodont, TR-42075 Konya, Turkey
[2] Karadeniz Tech Univ, Fac Dent, Dept Prosthodont, Trabzon, Turkey
[3] Gaziantep Univ, Fac Dent, Dept Prosthodont, Gaziantep, Turkey
[4] Denta Form, Ankara, Turkey
关键词
Er; Cr; YSGG; ICP-AES; mineral content; dentin;
D O I
10.1007/s10103-007-0498-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Laser etching has an effect on the mineral content of dentin. The aim of this study was to evaluate the mineral content of dentin prepared at three different power settings with an erbium, chromium:yttrium scandium gallium garnet (Er,Cr:YSGG) laser. The enamel of five, lower, wisdom, molar teeth was removed to expose the dentin surface. Four dentin slabs were obtained, then each tooth was randomly divided into four portions (groups 1 W, 2 W, 3 W and control) so that we could evaluate the effect of laser treatment. The Er,Cr:YSGG laser used for the study had a pulse duration of 140 mu s, a pulse repetition rate of 20 Hz and a power output range of 0 W to 6 W. Laser energy was delivered through a fiberoptic system to a sapphire tip terminal 6 mm long and 600 mu m in diameter, using a non-contact mode. The levels of five elements: magnesium (Mg), phosphorus (P), calcium (Ca), potassium (K), and sodium (Na), in each slab were measured by inductively coupled plasma-atomic emission spectrometry (ICP-AES). There were significant differences between the groups (1 W, 2 W, 3 W and control) for Ca, Mg, Na, P and Ca/P ratio (P<0.05); however, there were no significant differences for K (P=0.43). Laser treatment at 1 W significantly affected the mean percentage weight of all element groups except K. Scanning electron microscopy (SEM) photographs indicated that the surface irregularities increased with increasing power setting.
引用
收藏
页码:421 / 425
页数:5
相关论文
共 50 条
  • [21] Composite removal by means of erbium, chromium:yttrium-scandium-gallium-garnet laser compared with rotary instruments
    Tantbirojn, Daranee
    Walinski, Christopher J.
    Ross, Judith A.
    Taylor, Charlotte R.
    Versluis, Antheunis
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2019, 150 (12): : 1040 - 1047
  • [22] The use of the erbium, chromium:yttrium -: scandium-gallium-garnet laser in endodontic treatment -: The results of an in vitro study
    Schoop, Ulrich
    Goharkhay, Kawe
    Klimscha, Johannes
    Zagler, Manuela
    Wernisch, Johann
    Georgopoulos, Apostolos
    Sperr, Wolfgang
    Moritz, Andreas
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2007, 138 (07): : 949 - 955
  • [23] Clinical and Biochemical Effects of Erbium, Chromium: Yttrium, Scandium, Gallium, Garnet Laser Treatment as a Complement to Periodontal Treatment
    Ustun, K.
    Hatipoglu, M.
    Daltaban, O.
    Felek, R.
    Firat, M. Z.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (09) : 1150 - 1157
  • [24] Influence of etching with erbium, chromium:yttrium-scandium-gallium-garnet laser on microleakage of class V restoration
    Marotti, Juliana
    Geraldo-Martins, Vinicius Rangel
    Bello-Silva, Marina Stella
    Eduardo, Carlos de Paula
    Apel, Christian
    Gutknecht, Norbert
    LASERS IN MEDICAL SCIENCE, 2010, 25 (03) : 325 - 329
  • [25] Visualising the procedures in the influence of water on the ablation of dental hard tissue with erbium:yttrium–aluminium–garnet and erbium, chromium:yttrium–scandium–gallium-garnet laser pulses
    Maziar Mir
    Norbert Gutknecht
    Reinhart Poprawe
    Leon Vanweersch
    Friedrich Lampert
    Lasers in Medical Science, 2009, 24 : 365 - 374
  • [26] Evaluation of microleakage of root canal fillings irradiated with different output powers of erbium, chromium:yttrium-scandium-gallium-garnet laser
    Ozer, Senem Yigit
    Basaran, Emine
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (01) : 8 - 14
  • [27] Visualising the procedures in the influence of water on the ablation of dental hard tissue with erbium:yttrium-aluminium-garnet and erbium, chromium:yttrium-scandium-gallium-garnet laser pulses
    Mir, Maziar
    Gutknecht, Norbert
    Poprawe, Reinhart
    Vanweersch, Leon
    Lampert, Friedrich
    LASERS IN MEDICAL SCIENCE, 2009, 24 (03) : 365 - 374
  • [28] Erbium, chromium:Yttrium-scandium-gallium-garnet (Er, Cr:YSGG) laser versus diode laser in the treatment of pericoronitis
    Eroglu, C. N.
    Tunc, S. K.
    Yuksek, M. N.
    Elasan, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (07) : 980 - 985
  • [29] The impact of an erbium, chromium:yttrium-scandium-gallium-garnet laser with radial-firing tips on endodontic treatment
    Schoop, U.
    Barylyak, A.
    Goharkhay, K.
    Beer, F.
    Wernisch, J.
    Georgopoulos, A.
    Sperr, W.
    Moritz, A.
    LASERS IN MEDICAL SCIENCE, 2009, 24 (01) : 59 - 65
  • [30] Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions
    Botta, Sergio Brossi
    da Ana, Patricia Aparecida
    Zezell, Denise Maria
    Powers, John M.
    Matos, Adriana Bona
    LASERS IN MEDICAL SCIENCE, 2009, 24 (01) : 67 - 73