Sizing criteria of hybrid photovoltaic-wind systems with battery storage and self-consumption considering interaction with the grid

被引:66
|
作者
Bayod-Rujula, Angel A. [1 ]
Haro-Larrode, Marta E. [1 ]
Martinez-Gracia, Amaya [2 ]
机构
[1] Univ Zaragoza C, CIRCE Res Inst, Dept Elect Engn, Zaragoza 50018, Spain
[2] Univ Zaragoza C, CIRCE Res Inst, Dept Mech Engn, Zaragoza 50018, Spain
关键词
Hybrid systems; Photovoltaic and wind energy; Energy losses; Battery energy storage; Grid connection; ENERGY-SYSTEMS; TECHNOECONOMIC ANALYSIS; POWER-SYSTEMS; OPTIMIZATION; PV; GENERATION; DESIGN; METHODOLOGY; ARRAY; SIZE;
D O I
10.1016/j.solener.2013.10.023
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this paper is to analyze the influence of some sizing parameters of grid-connected, hybrid wind-photovoltaic systems provided with energy storage and load consumption, on their interaction with the electrical network. These sizing parameters are the sizing factor (defined as the ratio between the yearly energy produced by the renewable generation system and the yearly energy demanded by a consumer), the solar and wind fractions, and the size of the batteries. The analyzed case study is the supply of energy to a typical residential load in Spain. Annual hourly-based series of energy production from wind and photovoltaic installations in operation in Aragon (an eastern region of Spain) are used as data inputs to a Matlab model of the system. Yearly energy balances for hybrid systems with different combinations and sizes of photovoltaic (PV) plant and wind energy conversion system (WECS) plus Battery Storage Systems (BES) are simulated in an hourly basis. These hybrid systems can inject or absorb energy from the grid depending on whether the energy produced is higher or lower than the household consumption and their operational limits are not exceeded. The interaction with the grid is evaluated in terms of energy injected in or absorbed from the grid, electrical (Joule) losses in lines and load duration curves (LDCs). Although the problem is case-dependent and the correct sizing of such systems is only possible with the knowledge of generation and consumption profiles, some general criteria can be extracted from the results of this paper. Conclusions are also valid for pure PV or Wind systems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:582 / 591
页数:10
相关论文
共 50 条
  • [21] Multi-criteria optimal sizing of hybrid renewable energy systems including wind, photovoltaic, battery, and hydrogen storage with ε-constraint method
    Bakhtiari, Hamed
    Naghizadeh, Ramezan Ali
    [J]. IET RENEWABLE POWER GENERATION, 2018, 12 (08) : 883 - 892
  • [22] Implementation of planned power generation for a grid-tied photovoltaic system with a storage battery for self-consumption of local object
    Shavolkin, Olexandr
    Shvedchykova, Iryna
    Kolcun, Michal
    Medved, Dusan
    Demishonkova, Svitlana
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (01): : 18 - 27
  • [23] On the Influence of Electricity Demand Patterns, Battery Storage and PV System Design on PV Self-Consumption and Grid Interaction
    Litjens, Geert
    van Sark, Wilfried
    Worrell, Ernst
    [J]. 2016 IEEE 43RD PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2016, : 2021 - 2024
  • [24] Sizing and techno-economical optimization for hybrid solar photovoltaic wind power systems with battery storage
    Protogeropoulos, C
    Brinkworth, BJ
    Marshall, RH
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (06) : 465 - 479
  • [25] Comparing demand response and battery storage to optimize self-consumption in PV systems
    Lorenzi, Guido
    Santos Silva, Carlos Augusto
    [J]. APPLIED ENERGY, 2016, 180 : 524 - 535
  • [26] Solar photovoltaic-battery systems in Swedish households - Self-consumption and self-sufficiency
    Nyholm, Emil
    Goop, Joel
    Odenberger, Mikael
    Johnsson, Filip
    [J]. APPLIED ENERGY, 2016, 183 : 148 - 159
  • [27] Comparative analysis of design criteria for hybrid photovoltaic/wind/battery systems
    Vergara, Pedro Pablo
    Rey, Juan M.
    Pereira da Silva, Luiz C.
    Ordonez, Gabriel
    [J]. IET RENEWABLE POWER GENERATION, 2017, 11 (03) : 253 - 261
  • [28] Optimal operation, configuration and sizing of generation and storage technologies for residential heat pump systems in the spotlight of self-consumption of photovoltaic electricity
    Beck, T.
    Kondziella, H.
    Huard, G.
    Bruckner, T.
    [J]. APPLIED ENERGY, 2017, 188 : 604 - 619
  • [29] Design criteria for the optimal sizing of a hybrid energy storage system in PV household-prosumers to maximize self-consumption and self-sufficiency
    Hernandez, J. C.
    Sanchez-Sutil, F.
    Munoz-Rodriguez, F. J.
    [J]. ENERGY, 2019, 186
  • [30] Impact of Demand Side Management on the Self Sufficiency and Self-Consumption of Buildings with Photovoltaic and Storage Systems
    Kelepouris, Nikolaos S.
    Nousdilis, Angelos, I
    Bouhouras, Aggelos S.
    Christoforidis, Georgios C.
    Yerasimou, Yerasimos
    Chatzigeorgiou, Nikolas G.
    Georghiou, George E.
    Celli, Gianni
    Mocci, Susanna
    Gal, Erez
    Grigorovitch, Marina
    Topel, Elad
    [J]. PROCEEDINGS OF 9TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS 2021), 2021,