Measurement of transformer remaining useful life has long been a goal for responsible asset management. Most testing laboratories offer furan concentration testing as a suitable method. The interpretive method of choice is usually the Chendong equation expressed in practical terms as degree of polymeri zation of the paper with new paper at about 1000 and end of life at around 300. Typical mill transformers have insulation ratings expressed as 55 degrees C rises for plain kraft or 65 degrees C which corresponds to thermally upgraded kraft paper (TUP). It has been determined that TUP paper does not produce Furans and thus provides a false indicator of the cellulose breakdown. There are several papers currently in circulation that have demonstrated that a measurement of Methanol (MeOH) may be a better method to determine ageing of the TUP insulation and also for transformers with regular kraft paper insulation. The objective of this paper is to provide an overview of the reasons why furans should not be used as the basis for measuring degradation of thermally upgraded paper, why methanol should be so used, and to compare actual furans and methanol test data for service aged transformers in a process industry application
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Factors Affecting the Ageing of Transformer Oil in 150/20 kV Transformers
    Missas, Sotirios
    Danikas, Michael G.
    Liapis, Ioannis
    [J]. 2011 IEEE INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2011,
  • [42] Insulation Condition Assessment of Power Transformers Using Accelerated Ageing Tests
    Mirzaie, Mohammad
    Gholami, Ahmad
    Tayebi, Hamid Reza
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2009, 17 (01) : 39 - 54
  • [43] Ageing and Degradation of Power Transformers - How to Interpret Return Voltage Measurements
    Patsch, Rainer
    Menzel, Johannes
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 59 - 59
  • [44] Ageing in Singapore:: Service needs and the state
    Schroder-Butterfill, Elisabeth
    [J]. AGEING & SOCIETY, 2007, 27 : 450 - 452
  • [45] Ageing in Singapore: Service needs and the state
    Oehlers, Alfred
    [J]. JOURNAL OF CONTEMPORARY ASIA, 2008, 38 (02) : 337 - 339
  • [46] BLOOD METHANOL AS A MARKER OF ALCOHOL-ABUSE
    ROINE, R
    ERIKSSON, CJP
    YLIKAHRI, R
    PENTTILA, A
    SALASPURO, M
    [J]. ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1988, 12 (02) : 331 - 331
  • [47] Neutral Grounding in MV Transformers Substations for Cranes Service
    Parise, Giuseppe
    Parise, Luigi
    Martufi, Marco
    Su, Chun-Lien
    Chavdarian, P.
    Panetta, Sergio
    [J]. 2015 51ST IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2015,
  • [48] SERVICE EXPERIENCE WITH DISTRIBUTION TRANSFORMERS WITHOUT OIL CONSERVATORS
    KASERMANN, P
    [J]. BROWN BOVERI REVIEW, 1976, 63 (07): : 462 - 464
  • [49] Online condition monitoring system for substation and service transformers
    Ballal, Makarand S.
    Jaiswal, Gajanan C.
    Tutkane, Dhananjay R.
    Venikar, Prasad A.
    Mishra, Mahesh Kumar
    Suryawanshi, Hiralal M.
    [J]. IET ELECTRIC POWER APPLICATIONS, 2017, 11 (07) : 1187 - 1195
  • [50] RELIABILITY CHARACTERISTICS FOR 110 KV POWER TRANSFORMERS IN SERVICE
    TUFANOV, VA
    [J]. ELECTRICAL TECHNOLOGY, 1971, 4 : 140 - &