Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy

被引:60
|
作者
Del Pizzo, JJ
Sklar, GN
You-Cheong, JW
Levin, B
Krebs, T
Jacobs, SC
机构
[1] Univ Maryland, Sch Med, Div Urol, Dept Surg, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Radiol, Baltimore, MD 21201 USA
来源
JOURNAL OF UROLOGY | 1999年 / 162卷 / 01期
关键词
tomography; angiography; laparoscopy; kidney transplantation;
D O I
10.1097/00005392-199907000-00008
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Traditionally, live renal donors are evaluated with excretory urography and renal arteriography. Helical computerized tomography (CT) arteriography offers a less invasive alternative for demonstrating necessary anatomical information before laparoscopic allograft harvest. We evaluate the accuracy of helical CT arteriography in depicting renal vascular anatomy with an emphasis on the detection of arterial and venous anomalies. Materials and Methods: Imaging studies were done on 175 patients according to a standard CT arteriography protocol with early arterial phase scanning (14 to 20-second delay), and 1 mm. axial and 3-dimensional maximum intensity projection reconstructions. Renal vascular anatomy was mapped with attention to aberrant arterial and venous anatomy. Intraoperative findings were correlated at laparoscopic donor nephrectomy. Results: There was overall agreement between CT arteriography and laparoscopic findings in 163 cases (93%). Supernumerary renal arteries were identified in 40 cases (23%). Sensitivity, specificity and accuracy of CT arteriography for arterial anatomy were 91, 98 and 96%, respectively. Cases with less than 2 mm. accessory arteries or early branching single vessels simulating dual arteries were misdiagnosed. Venous anomalies occurred in 11 patients (6.3%). Sensitivity, specificity and accuracy of CT arteriography for venous anatomy were 65, 100, and 97%, respectively. Misdiagnoses included early venous bifurcations and supernumerary tributary veins, which were poorly opacified. Conclusions: Helical CT is highly accurate and specific for the demonstration of renal arterial anatomy. Poor opacification resulted in a lower sensitivity for venous anatomy. Overall, helical CT provides essential anatomical information, and is an alternative to standard urography and arteriography.
引用
收藏
页码:31 / 34
页数:4
相关论文
共 50 条
  • [21] Comparative study of helical CT scan angiography, conventional arteriography, and intraoperative findings for the evaluation of living renal transplant donors
    Manu, MA
    Harza, M
    Manu, R
    Georgescu, S
    Lesaru, M
    Toma, H
    Sinescu, I
    TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) : 2028 - 2029
  • [22] Impact of renal artery multiplicity on outcomes of renal donors and recipients in laparoscopic donor nephrectomy
    Hsu, THS
    Su, LM
    Ratner, LE
    Trock, BJ
    Kavoussi, LR
    UROLOGY, 2003, 61 (02) : 323 - 327
  • [23] Open versus laparoscopic donor nephrectomy in live related renal transplantation
    Kaçar, S
    Gürkan, A
    Karaca, C
    Varilsüha, C
    Karaoglan, M
    Akman, F
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (09) : 2620 - 2622
  • [24] Degloving of the renal capsule: A rare complication of laparoscopic live donor nephrectomy
    Hammer, Clarisa
    Hawasli, Abdelkader
    Meguid, Ahmed
    Oh, Henry
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2006, 16 (04): : 362 - 364
  • [25] Laparoscopic live donor nephrectomy: Current practice and results of renal transplantation
    Yip, Sidney Kam-Hung
    Leung, Chi-Bon
    Szeto, Cheuk-Chun
    Lam, Nga-Yee
    Chan, Chi-Kwok
    Tong, Yuen-Fan
    Ng, Chi-Fai
    Kwan, Bonnie Ching-Ha
    Chow, Kai-Ming
    Chan, Eddie Shu-Yin
    Hou, Simon See-Ming
    Yu, Alex Wai-Yin
    Li, Philip Kam-Tao
    SURGICAL PRACTICE, 2012, 16 (01) : 17 - 21
  • [27] Laparoscopic live donor nephrectomy in the presence of a circumaortic renal vein: The video
    Lovallo, G. G.
    Volfson, I. A.
    Shapiro, M. E.
    Munver, R.
    JOURNAL OF ENDOUROLOGY, 2006, 20 : A301 - A301
  • [28] RENAL TRAUMA - EVALUATION BY COMPUTERIZED-TOMOGRAPHY
    ERTURK, E
    SHEINFELD, J
    DIMARCO, PL
    COCKETT, ATK
    JOURNAL OF UROLOGY, 1985, 133 (06): : 946 - 949
  • [29] EVALUATION OF RENAL INJURIES WITH COMPUTERIZED-TOMOGRAPHY
    PETERSON, NE
    JOURNAL OF UROLOGY, 1983, 130 (06): : 1204 - 1204
  • [30] EVALUATION OF RENAL INJURIES WITH COMPUTERIZED-TOMOGRAPHY
    MCANINCH, JW
    FEDERLE, MP
    GUERRIERO, WG
    JOURNAL OF UROLOGY, 1982, 128 (03): : 456 - 460