International Results with the Boston Type I Keratoprosthesis

被引:134
|
作者
Aldave, Anthony J. [1 ]
Sangwan, Virender S. [2 ]
Basu, Sayan [2 ]
Basak, Samar K. [3 ]
Hovakimyan, Anna [4 ]
Gevorgyan, Ofelya [4 ]
Al Kharashi, Soliman [5 ]
Al Jindan, Mohanna [5 ]
Tandon, Radhika [6 ]
Mascarenhas, Jeena [7 ]
Malyugin, Boris [8 ]
Padilla, Ma Dominga B. [9 ]
Maskati, Quresh [10 ]
Agarwala, Nisheeta [11 ]
Hutauruk, Johan [12 ]
Sharma, Manoj [13 ]
Yu, Fei [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Jules Stein Eye Inst, Los Angeles, CA 90095 USA
[2] LV Prasad Eye Inst, Hyderabad, Andhra Pradesh, India
[3] Disha Eye Hosp, Kolkata, India
[4] Malayan Ophthalmlol Ctr, Yerevan, Armenia
[5] King Khalid Eye Specialist Hosp, Riyadh, Saudi Arabia
[6] All India Inst Med Sci, RP Ctr Ophthalm Sci, New Delhi, India
[7] Aravind Eye Hosp, Madurai, Tamil Nadu, India
[8] S Fyodorov Eye Microsurg Complex State Inst, Moscow, Russia
[9] Univ Philippines, Philippine Gen Hosp, Manila, Philippines
[10] Maskati Eye Clin, Mumbai, Maharashtra, India
[11] PD Hinduja Hosp, Mumbai, Maharashtra, India
[12] RS Cipto Mangunkusumo Hosp, Jakarta, Indonesia
[13] BP Koirala Inst Hlth Sci, Dharan, Nepal
关键词
ENDOPHTHALMITIS;
D O I
10.1016/j.ophtha.2012.02.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the indications and outcomes of Boston type 1 keratoprosthesis (Massachusetts Eye and Ear Infirmary, Boston, MA) surgery performed outside of North America and to compare them with those obtained in the United States by the surgeon who trained the international surgeons. Design: Retrospective review of consecutive clinical case series. Participants: One hundred ninety-four patients (223 keratoprosthesis procedures performed in 205 eyes) who received Boston type 1 keratoprosthesis at 11 ophthalmology centers in Armenia, India, Indonesia, Nepal, Philippines, Russia, and Saudi Arabia between May 1, 2006, and July 1, 2011 (international series), and at the Jules Stein Eye Institute between May 1, 2004, and July 1, 2011 (University of California, Los Angeles [UCLA] series). Methods: Data were collected for each procedure regarding the preoperative characteristics of each eye, the surgical procedure(s) performed, and the postoperative outcomes. Statistical analysis was performed to identify significant differences between the international and UCLA series in terms of retention and complications. Main Outcome Measures: Interval visual acuities, keratoprosthesis retention, and significant postoperative complications. Results: In the international series, 113 Boston type I keratoprostheses were implanted in 107 eyes of 100 patients. The most common indication for surgery was corneal graft failure (n = 50; 44%) followed by chemical injury (n = 30; 27%). Although only 2% of eyes had a preoperative corrected distance visual acuity (CDVA) of 20/20 to 20/200, 70%, 68%, and 59% of eyes had a postoperative CDVA of 20/20 to 20/200 at 6 months, 1 year, and 2 years after surgery, respectively. Ninety-one of the 113 keratoprostheses implanted (80.5%) were retained at a mean follow-up of 14.2 months, for a retention failure rate of 22 per 134.6 eye-years (0.163/eye-year). The most common postoperative complications were retroprosthetic membrane formation (27%) and sterile corneal necrosis (18%). The only postoperative complication that was more common in the international series than in the UCLA series was infectious endophthalmitis, which developed in 9% of eyes. Conclusions: Boston keratoprosthesis is a viable means of managing repeat graft failure and ocular chemical injury outside of North America, with similar visual acuity outcomes, retention rates, and incidence rates of postoperative complications to those obtained by North American surgeons. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2012;119:1530-1538 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:1530 / 1538
页数:9
相关论文
共 50 条
  • [31] Low vision rehabilitation in patients with Boston type I keratoprosthesis implant
    Ferraz, Nivea Nunes
    Michelin Gobbo, Laura Emilia
    Eliseo da Silva, Paula Baptista
    Leal, Ariadne Stavare
    Cypel, Marcela Colussi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [32] Outcomes of Boston keratoprosthesis type 1 reimplantation: multicentre study results
    Wang, Jay C.
    Rudnisky, Christopher J.
    Belin, Michael W.
    Ciolino, Joseph B.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (03): : 284 - 290
  • [33] Postoperative outcome in eyes with glaucoma treated with the Boston type I keratoprosthesis
    Romero, Pablo
    Chen, Philip P.
    Shen, Tueng T.
    Slabaugh, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [34] The Role of the Back Plate in Angle Anatomy with the Boston Type I Keratoprosthesis
    Taniguchi, Elise V.
    Paschalis, Eleftherios I.
    Crnej, Alja
    Ren, Ai
    Colby, Kathryn A.
    Chodosh, James
    Pasquale, Louis R.
    Shen, Lucy Q.
    Dohlman, Claes H.
    Cruzat, Andrea
    CORNEA, 2017, 36 (09) : 1096 - 1101
  • [35] Infectious Endophthalmitis in Adult Eyes Receiving Boston Type I Keratoprosthesis
    Ramchandran, Rajeev S.
    DiLoreto, David A., Jr.
    Chung, Mina M.
    Kleinman, David M.
    Plotnik, Ronald P.
    Graman, Paul
    Aquavella, James V.
    OPHTHALMOLOGY, 2012, 119 (04) : 674 - 681
  • [36] Mid-term prognosis of type I Boston keratoprosthesis reimplantation
    Bouhout, Soumaya
    Robert, Marie-Claude
    Harissi-Dagher, Mona
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (01) : 37 - 41
  • [37] Boston type I keratoprosthesis implantation technique. Video article
    Matthaei, M.
    Bachmann, B.
    Hos, D.
    Siebelmann, S.
    Schaub, F.
    Cursiefen, C.
    OPHTHALMOLOGE, 2019, 116 (01): : 67 - 72
  • [38] Outcomes of the Boston Type I Keratoprosthesis as the Primary Penetrating Corneal Procedure
    Driver, Todd H.
    Aravena, Carolina
    Duong, Huong N. V.
    Christenbury, Joseph G.
    Yu, Fei
    Basak, Samar K.
    Aldave, Anthony J.
    CORNEA, 2018, 37 (11) : 1400 - 1407
  • [39] Glaucoma Implants for the Control of Intraocular Pressure With Type I Boston Keratoprosthesis
    Wong, J. J.
    Vajaranant, T. S.
    Wilensky, J. T.
    de la Cruz, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Improved centration of the type I Boston Keratoprosthesis in donor carrier tissue
    Khalifa, Yousuf M.
    Moshirfar, Majid
    CLINICAL OPHTHALMOLOGY, 2010, 4 : 931 - 933