Noninvasive and nonocclusive determination of blood pressure using laser Doppler flowmetry

被引:2
|
作者
Elter, P [1 ]
Stork, W [1 ]
Müller-Glaser, KD [1 ]
Lutter, N [1 ]
机构
[1] Univ Karlsruhe, Inst Informat Proc Technol, D-76128 Karlsruhe, Germany
关键词
blood pressure; noninvasive; laser; Doppler; flowmetry;
D O I
10.1117/12.346715
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This report describes an approach determining blood pressure noninvasively without cuff. Regarding an elastic, fluid-filled tube as a model of an arterial segment, the solution of the Navier Stokes differential equations delivers a relation between the pressure and velocity pulse. There, simulations prove a minimal sensitivity of blood pressure concerning blood density, blood viscosity and damping. Hence, these parameters can be regarded interindividually as constants. Blood pressure is essentially sensitive on the pulse wave velocity, the velocity pulse, the arterial diameter and the reflection coefficient. To perform measurements, a system was built up comprising at least one laser Doppler blood flow sensor, a high performance DSP hardware and a PC. After individual initial Riva Rocci calibration, arterial diameter and reflection coefficient can be determined. Flow and pulse wave velocity and thus blood pressure can be calculated measuring continuously at least one velocity pulse with the laser Doppler flow sensor at a superficial artery like the a. radialis and simultaneously another cardiovascular signal like an ECG or another flow pulse at a different site of the artery. As a first result, high linear correlations between systolic blood pressure and pulse transit time were obtained.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 50 条
  • [31] Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels
    Elter, P
    Seiter, E
    Karch, T
    Stork, W
    Müller-Glaser, KD
    Lutter, N
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 244 - 254
  • [32] Blood flow in the human iris measured by laser Doppler flowmetry
    Chamot, SR
    Movaffaghy, AM
    Petrig, BL
    Riva, CE
    MICROVASCULAR RESEARCH, 1999, 57 (02) : 153 - 161
  • [33] MEASUREMENT OF COLONIC BLOOD-FLOW WITH LASER DOPPLER FLOWMETRY
    AHN, H
    LINDHAGEN, J
    LUNDGREN, O
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (07) : 871 - 880
  • [34] TENDON BLOOD-FLOW ASSESSED BY LASER DOPPLER FLOWMETRY
    ASTROM, M
    SVENSSON, H
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1991, 25 (03): : 213 - 215
  • [35] ASSESSMENT OF GASTRIC BLOOD-FLOW WITH LASER DOPPLER FLOWMETRY
    AHN, H
    IVARSSON, LE
    JOHANSSON, K
    LINDHAGEN, J
    LUNDGREN, O
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 (10) : 1203 - 1210
  • [36] Laser doppler blood flowmetry in type 1 diabetic retinopathy
    Jackson, WE
    Orgon, CE
    Mitchell, G
    Aly, T
    Vendrame, F
    DIABETES, 2005, 54 : A560 - A560
  • [37] Assessment of Retinal/Choroidal Blood Flow Using Laser Doppler Flowmetry (LDF) in Rats
    Hetu, S.
    Cordahi, G.
    Couture, R.
    Vaucher, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [38] Blood flow measurement in reconstructed anterior cruciate ligaments using laser Doppler flowmetry
    Yamagishi T.
    Fujii K.
    Roppongi S.
    Hatsuumi H.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (3) : 160 - 164
  • [39] MEASUREMENT OF FLAP BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    GOTO, M
    ISHIKAWA, K
    KATSUKI, T
    LASERS IN DENTISTRY, 1989, 850 : 163 - 168
  • [40] Measurement of blood perfusion in the dental pulp with laser Doppler flowmetry
    Firestone, AR
    Wheatley, AM
    Thüer, UW
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1997, 17 (06): : 298 - 304