Assessment of the Positioning Accuracy of DGPS and EGNOS Systems in the Bay of Gdansk using Maritime Dynamic Measurements

被引:46
|
作者
Specht, Cezary [1 ]
Pawelski, Jan [2 ]
Smolarek, Leszek [3 ]
Specht, Mariusz [3 ]
Dabrowski, Pawel [1 ]
机构
[1] Gdynia Maritime Univ, Fac Nav, Dept Geodesy & Oceanog, Sedzickiego 19, PL-81347 Gdynia, Poland
[2] Gdynia Maritime Univ, Fac Nav, Dept Ships Operat, Aleja Jana Pawla 2 3, PL-81345 Gdynia, Poland
[3] Gdvnia Maritime Univ, Fac Nav, Dept Transport & Logist, Morska 81-87, PL-81225 Gdynia, Poland
来源
JOURNAL OF NAVIGATION | 2019年 / 72卷 / 03期
关键词
Positioning accuracy; DGPS; EGNOS; Satellite measurements;
D O I
10.1017/S0373463318000838
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Differential Global Positioning Systems (DGPS) and the European Geostationary Navigation Overlay Service (EGNOS) are included in a group of supporting systems (Ground-Based Augmentation System (GBAS)/Space-Based Augmentation System (SBAS)) for the American GPS. Their main task is to ensure better positioning characteristics (accuracy, reliability, continuity and availability) compared to GPS. Therefore, they are widely applied wherever GPS failures affect human safety, mainly in aviation, land and marine navigation. The aim of this paper is to assess the predictable positioning accuracy of DGPS and EGNOS receivers using a vessel manoeuvring in the Bay of Gdansk. Two receivers were used in the study: a Simrad MXB5 (DGPS) and a Trimble GA530 (EGNOS), which were simultaneously recording their coordinates. The obtained values were compared with the trajectory computed using a geodetic Global Navigation Satellite System (GNSS) receiver (Trimble R10) connected to a GNSS network, ensuring an accuracy of 2-3 cm (p = 0 center dot 95). During a four-hour measurement session, the accuracy statistics of these systems were determined based on around 11,500 positionings. Studies have shown that both positioning systems ensure a similar level of accuracy of their positioning services (approximately 0 center dot 5-2 m) and they meet the accuracy requirements set in published standards.
引用
收藏
页码:575 / 587
页数:13
相关论文
共 50 条
  • [31] Determination of Navigation System Positioning Accuracy Using the Reliability Method Based on Real Measurements
    Specht, Mariusz
    REMOTE SENSING, 2021, 13 (21)
  • [32] Assessment of Voltage Instrument Transformers Accuracy for Harmonic Measurements in Transmission Systems
    Stiegler, Robert
    Meyer, Jan
    Kilter, Jako
    Konzelmann, Simon
    PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, : 152 - 157
  • [33] ASSESSMENT OF ACCURACY OF RTK MEASUREMENTS USING VARIOUS COMBINATIONS OF GNSS
    Siejka, Zbigniew
    INFORMATICS, GEOINFORMATICS AND REMOTE SENSING CONFERENCE PROCEEDINGS, SGEM 2016, VOL II, 2016, : 117 - 123
  • [34] Reliability assessment of multi-megawatt capacity offshore dynamic positioning systems
    Vedachalam, N.
    Ramadass, G. A.
    APPLIED OCEAN RESEARCH, 2017, 63 : 251 - 261
  • [35] A comparison of positioning accuracy for frameless lung SBRT using two immobilization systems
    Penedo Cobos, J. M.
    Luna, J.
    Garcia, M. A.
    Lopez, E.
    Aguilar, K.
    Gonzalez, R.
    Sanchez, A.
    Gomez-Tejedor, S.
    Rincon, M.
    Alarcia, M.
    Martin, S.
    Gonsalves, D.
    Olivera, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1069 - S1069
  • [36] Dynamic Star Positioning Accuracy Improving Method Using Coded Exposure for Star Sensor
    Ma, Yan
    Jiang, Jie
    Wang, Gangyi
    Li, Jian
    Wang, Zhen
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [37] Condition Assessment of Composite Structures using Dynamic Measurements
    Zhu, Xinqun
    Uy, Brian
    Mirza, Olivia
    Hao, Hong
    DYNAMICS FOR SUSTAINABLE ENGINEERING, VOL 1, 2011, : 307 - 316
  • [38] Accuracy and Precision Assessment of AoA-Based Indoor Positioning Systems Using Infrastructure Lighting and a Position-Sensitive Detector
    De-La-Llana-Calvo, Alvaro
    Salido-Monzu, David
    Lazaro-Galilea, Jose-Luis
    Gardel-Vicente, Alfredo
    Bravo-Munoz, Ignacio
    Rubiano-Muriel, Borja
    SENSORS, 2020, 20 (18) : 1 - 21
  • [39] The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements
    Naus, Krzysztof
    Nowak, Aleksander
    SENSORS, 2016, 16 (08)
  • [40] Application of adaptive filtering for improving the accuracy of ground displacement measurements by using the Global Positioning System
    Shimizu, Norikazu
    Egami, Tomoyuki
    Nakagawa, Koji
    Sakurai, Shunsuke
    Doboku Gakkai Rombun-Hokokushu/Proceedings of the Japan Society of Civil Engineers, 1994, (487 pt 3-26): : 275 - 278