Advanced DC zonal marine power system protection

被引:38
|
作者
Jia, Ke [1 ]
Christopher, Edward [2 ]
Thomas, David [2 ]
Sumner, Mark [2 ]
Bi, Tianshu [1 ]
机构
[1] North China Elect Power Univ, Beijing, Peoples R China
[2] Univ Nottingham, Nottingham NG7 2RD, England
关键词
IMPEDANCE MEASUREMENT; QUALITY;
D O I
10.1049/iet-gtd.2013.0139
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new active impedance estimation based protection strategy which is suitable for utilisation in a DC zonal marine power distribution system is presented. This method uses two triangular current 'spikes' injections for system impedance estimation and protection when faults are detected. By comparing the estimated impedance with the pre-calibrated value, the fault location can be predicted and fault can be isolated without requiring communication between two injection units. Using co-ordinated double injections and line current measurement (directional fault detection), faults in the system with same impedance and different fault positions can be distinguished, located and isolated. The proposed method is validated using experimental test results derived from a 30 kW, 400 V, twin bus DC marine power system demonstrator. The experimental tests were applied to both faults during normal operation and faults that occur during system restoration. © The Institution of Engineering and Technology 2014.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [21] Experimental study on coordination of protection for low-voltage AC network in DC zonal distribution system
    Wang, R. (wangrt4321@163.com), 1600, Power System Technology Press (38):
  • [22] Impact of Synchronous Generator Deexcitation Dynamics on the Protection in Marine DC Power Distribution Networks
    Kim, Seongil
    Kim, Soo-Nam
    Dujic, Drazen
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (01): : 267 - 275
  • [23] Dynamic Modeling, Simulation, and Testing of a Marine DC Hybrid Power System
    Ghimire, Pramod
    Zadeh, Mehdi
    Pedersen, Eilif
    Thorstensen, Jarle
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (02): : 905 - 919
  • [24] Fault Location in DC Marine Power System Using Multiple Injections
    Jia, Ke
    Christopher, Edward
    Sumner, Mark
    Thomas, David
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [25] DC Marine Power System: Transient Behavior and Fault Management Aspects
    Satpathi, Kuntal
    Ukil, Abhisek
    Nag, Soumya Shubhra
    Pou, Josep
    Zagrodnik, Michael Adam
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (04) : 1911 - 1925
  • [26] Characteristic Analysis of UHVAC/DC Hybrid Power Grids and Construction of Power System Protection
    Shu, Yinbiao
    Chen, Guoping
    Yu, Zhao
    Zhang, Jianyun
    Wang, Chao
    Zheng, Chao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2017, 3 (04): : 325 - 333
  • [27] Research of DC feeder protection based on bilateral power supply system
    Zhengzhou Railway Vocational and Technical College, Zhengzhou 450052, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2007, 11 (55-59):
  • [28] Power System Asset Management using Advanced Protection Relays
    Balakrishna, P.
    Kanabar, Mital
    Muthukrishnan, Vijaysarathi
    2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, : 836 - 841
  • [29] Fault Analysis and Protection in Flexible DC Traction Power Supply System
    Li B.
    Chen D.
    He J.
    Wang C.
    Song J.
    Lyu H.
    IEEE Transactions on Transportation Electrification, 2024, 10 (03) : 1 - 1
  • [30] Advanced protection solutions for improved power system dynamics performance
    Kojovic, LA
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 581 - 586