Advanced DC zonal marine power system protection

被引:38
|
作者
Jia, Ke [1 ]
Christopher, Edward [2 ]
Thomas, David [2 ]
Sumner, Mark [2 ]
Bi, Tianshu [1 ]
机构
[1] North China Elect Power Univ, Beijing, Peoples R China
[2] Univ Nottingham, Nottingham NG7 2RD, England
关键词
IMPEDANCE MEASUREMENT; QUALITY;
D O I
10.1049/iet-gtd.2013.0139
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new active impedance estimation based protection strategy which is suitable for utilisation in a DC zonal marine power distribution system is presented. This method uses two triangular current 'spikes' injections for system impedance estimation and protection when faults are detected. By comparing the estimated impedance with the pre-calibrated value, the fault location can be predicted and fault can be isolated without requiring communication between two injection units. Using co-ordinated double injections and line current measurement (directional fault detection), faults in the system with same impedance and different fault positions can be distinguished, located and isolated. The proposed method is validated using experimental test results derived from a 30 kW, 400 V, twin bus DC marine power system demonstrator. The experimental tests were applied to both faults during normal operation and faults that occur during system restoration. © The Institution of Engineering and Technology 2014.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [1] Active fault protection for an AC zonal marine power system
    Wang, J.
    Sumner, M.
    Thomas, D. W. P.
    Geertsma, R. D.
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2011, 1 (04) : 156 - 166
  • [2] Active Fault Protection for an AC Zonal Marine Power System Architecture
    Wang, J.
    Kadanak, P.
    Sumner, M.
    Thomas, D. W. P.
    Geertsma, R. D.
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 623 - +
  • [3] Fault Location in a Zonal DC Marine Power System Using Active Impedance Estimation
    Christopher, Edward
    Sumner, Mark
    Thomas, David W. P.
    Wang, Xiaohui
    de Wildt, Frans
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (02) : 860 - 865
  • [4] Fault Location in a Zonal DC Marine Power System using Active Impedance Estimation
    Christopher, Edward
    Sumner, Mark
    Thomas, David
    Wang, Xiaohui
    de Wiidt, Frans
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 3050 - 3054
  • [5] System Protection for Vessel DC Zonal Electrical System Supplied by Medium Voltage DC
    Wang, Rui Tian
    Fu, Li Jun
    Xiao, Fei
    Fan, Xue Xin
    2013 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD), 2013, : 89 - 93
  • [6] Overvoltage Protection on a DC Marine Electrical System
    Fletcher, S. D. A.
    Norman, P. J.
    Galloway, S. J.
    Burt, G. M.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 411 - 415
  • [7] Overcurrent protection in DC zonal shipboard power systems using solid state protection devices
    Baran, Mesut E.
    Teleke, Sercan
    Bhattacharya, Subliashish
    2007 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2007, : 221 - +
  • [8] Protection Coordination for Reliable Marine DC Power Distribution Networks
    Kim, Seongil
    Ulissi, Gabriele
    Kim, Soo-Nam
    Dujic, Drazen
    IEEE ACCESS, 2020, 8 : 222813 - 222823
  • [9] Security assessment of DC zonal Naval-ship power system
    Momoh, JA
    Kaddah, SS
    Salawu, W
    LESCOPE 01: 2001 LARGE ENGINEERING SYSTEMS CONFERENCE ON POWER ENGINEERING, CONFERENCE PROCEEDINGS, 2001, : 206 - 212
  • [10] Reconfiguration Optimization of DC Zonal Distribution Network of Shipboard Power System
    Li Ouyang
    Yong Li
    Yi Tan
    Xiao, Juanxia
    Cao, Yijia
    2016 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2016, : 444 - 448