Pressure-volume analysis during axial flow ventricular assist device support

被引:6
|
作者
McConnell, PI [1 ]
Sun, BC [1 ]
机构
[1] Ohio State Univ, Med Ctr, Div Cardiovasc Surg, Columbus, OH 43210 USA
来源
关键词
D O I
10.1016/j.healun.2005.05.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:256 / 257
页数:2
相关论文
共 50 条
  • [41] Readmissions After Implantation of Axial Flow Left Ventricular Assist Device
    Hasin, Tal
    Marmor, Yariv
    Kremers, Walter
    Topilsky, Yan
    Severson, Cathy J.
    Schirger, John A.
    Boilson, Barry A.
    Clavell, Alfredo L.
    Rodeheffer, Richard J.
    Frantz, Robert P.
    Edwards, Brooks S.
    Pereira, Naveen L.
    Stulak, John M.
    Joyce, Lyle
    Daly, Richard
    Park, Soon J.
    Kushwaha, Sudhir S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (02) : 153 - 163
  • [42] AXIAL-FLOW VENTRICULAR ASSIST DEVICE - SYSTEM PERFORMANCE CONSIDERATIONS
    DAMM, G
    MIZUGUCHI, K
    ABER, G
    BACAK, J
    AKKERMAN, J
    BOZEMAN, R
    SVEJKOVSKY, P
    TAKATANI, S
    NOSE, Y
    NOON, GP
    DEBAKEY, ME
    ARTIFICIAL ORGANS, 1994, 18 (01) : 44 - 48
  • [43] Modeling and control of a brushless DC axial flow ventricular assist device
    Giridharan, CA
    Skliar, M
    Olsen, DB
    Pantalos, GM
    ASAIO JOURNAL, 2002, 48 (03) : 272 - 289
  • [44] Modeling of the human circulatory system with an axial flow ventricular assist device
    Giridharan, GA
    Skliar, M
    PROCEEDINGS OF THE 2001 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2001, : 3801 - 3806
  • [45] Ethical Analysis of Withdrawing Ventricular Assist Device Support
    Mueller, Paul S.
    Swetz, Keith M.
    Freeman, Monica R.
    Carter, Kari A.
    Crowley, Mary Eliot
    Severson, Cathy J. Anderson
    Park, Soon J.
    Sulmasy, Daniel P.
    MAYO CLINIC PROCEEDINGS, 2010, 85 (09) : 791 - 797
  • [46] VENTRICULAR DISTENSIBILITY AND PRESSURE-VOLUME CURVE DURING SYMPATHETIC STIMULATION
    SONNENBLICK, EH
    SARNOFF, SJ
    SIEGEL, JH
    AMERICAN JOURNAL OF PHYSIOLOGY, 1963, 204 (02): : 1 - &
  • [47] Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation
    Koenig, SC
    Pantalos, GM
    Gillars, KJ
    Ewert, DL
    Litwak, KN
    Etoch, SW
    ASAIO JOURNAL, 2004, 50 (01) : 15 - 24
  • [48] Flow Visualization of a Pediatric Ventricular Assist Device During Stroke Volume Reductions Related to Weaning
    Roszelle, Breigh N.
    Deutsch, Steven
    Weiss, William J.
    Manning, Keefe B.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (07) : 2046 - 2058
  • [49] Flow Visualization of a Pediatric Ventricular Assist Device During Stroke Volume Reductions Related to Weaning
    Breigh N. Roszelle
    Steven Deutsch
    William J. Weiss
    Keefe B. Manning
    Annals of Biomedical Engineering, 2011, 39
  • [50] Noninvasive means for preload reduction during analysis of left ventricular pressure-volume relations
    Haney, MF
    Goran, J
    Soren, H
    Bjorn, B
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A85 - A85