Determination of metal-cofactors in enzyme complexes by total-reflection X-ray fluorescence spectrometry

被引:22
|
作者
Wittershagen, A
RostamKhani, P
Klimmek, O
Gross, R
Zickermann, V
Zickermann, I
Gemeinhardt, S
Kroger, A
Ludwig, B
Kolbesen, BO
机构
[1] UNIV FRANKFURT,INST INORGAN CHEM ANALYT CHEM,D-60439 FRANKFURT,GERMANY
[2] INST MICROBIOL,D-60439 FRANKFURT,GERMANY
[3] INST BIOPHYS CHEM & BIOCHEM,D-60439 FRANKFURT,GERMANY
关键词
Total-Reflection X-ray Fluorescence spectrometry; metal-cofactors; enzymatic samples;
D O I
10.1016/S0584-8547(96)01639-4
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The determination of metal-cofactors and their molar concentrations is an important requirement for the characterisation of metalloproteins and a challenge regarding the capabilities of trace analytical methods. In this respect, total-reflection X-ray fluorescence spectrometry offers many advantages for the determination of trace elements in enzymes, as compared to other well known analytical techniques such as flame atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry (ICP-AES), because of the significantly smaller amounts of sample required. Without any decomposition, elements like P, S, Fe, Ni, Cu, Zn, Mn and Mo could be determined with high accuracy, in spite of the large bio-organic matrix. The enzymes (polysulphide reductase and hydrogenase of the rumen bacterium Wolinella succinogenes, and the cytochrome c oxidase and quinol oxidase of the soil bacterium Paracoccus denitrificans) were transferred from their usual salt-buffer into a solution of 100 mmol l(-1) tris(hydroxymethyl)aminomethane (tris)-acetate containing an appropriate detergent. By this procedure, an improved signal-to-noise ratio is obtained. The polysulphide reductase; was found to contain copper as a hitherto existing unknown cofactor. The enzyme contains a stretch of amino acids that are typical of copper proteins and thus confirm the presence of this element. Furthermore, the data concerning cytochrome c oxidase from Paracoccus denitrificans are in good agreement with published values obtained by ICP-AES. Also, results from measurements with the quinol oxidase from the same bacterium agree with the expected values. The investigations lead to the conclusion that the method is well suited to the quantitative determination of metals in enzymes, in particular their molar fractions, and requires only small amounts of the biological sample without any extensive pretreatment. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1033 / 1038
页数:6
相关论文
共 50 条
  • [31] Determination of trace elements in macrozoobenthos samples by total-reflection X-ray fluorescence analysis
    Miesbauer, H
    Köck, G
    Füreder, L
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2203 - 2207
  • [32] Sapphire sample carriers for silicon determination by total-reflection X-ray fluorescence analysis
    Theisen, M
    Niessner, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (13) : 1839 - 1848
  • [33] Trace Element Determination in Diesel Particulates by Total-Reflection X-Ray Fluorescence Analysis
    Juha K. Vilhunen
    Alex von Bohlen
    Martina Schmeling
    Leena Rantanen
    Seppo Mikkonen
    Reinhold Klockenkämper
    Dieter Klockow
    Microchimica Acta, 1999, 131 : 219 - 223
  • [34] Direct determination of metal concentrations in freshwater algae by total reflection X-ray fluorescence spectrometry
    Barkács, K
    Varga, A
    Cál-Solymos, K
    Záray, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) : 577 - 581
  • [35] New method of fractional air particle sampling for total-reflection X-ray fluorescence spectrometry
    John, AC
    Kuhlbusch, TAJ
    Fissan, H
    Schmidt, KG
    Schmidt, F
    Pfeffer, HU
    Gladtke, D
    PROCEEDINGS OF THE 14TH FRENCH CONGRESS ON AEROSOLS CFA 98, 1998, : 229 - 233
  • [36] Suitability and Applications of Total-Reflection X-Ray Fluorescence Spectrometry for Analytical Characterization of Nuclear Materials
    Sanyal, Kaushik
    Dhara, Sangita
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2024,
  • [37] Development and validation of a method for multielement analysis of apatite by total-reflection X-ray fluorescence spectrometry
    Maltsev, Artem S.
    Ivanov, Alexei, V
    Chubarov, Victor M.
    Pashkova, Galina, V
    Panteeva, Svetlana, V
    Reznitskii, Leonid Z.
    TALANTA, 2020, 214
  • [38] Total-reflection x-ray microscopy
    Jibaoui, H
    Erre, D
    Cazaux, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (07): : 2966 - 2970
  • [39] Survey of sampling techniques for solids suitable for microanalysis by total-reflection X-ray fluorescence spectrometry
    Klockenkämper, R
    von Bohlen, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) : 571 - 576
  • [40] APPLICATION OF TOTAL-REFLECTION X-RAY-FLUORESCENCE SPECTROMETRY IN MATERIAL ANALYSIS
    HOFFMANN, P
    HEIN, M
    SCHEUER, V
    LIESER, KH
    MIKROCHIMICA ACTA, 1990, 2 (1-6) : 305 - 313