Sensitive electrochemical detection of methyl parathion in the presence of para-nitrophenol on a glassy carbon electrode modified by a functionalized NiAl-layered double hydroxide

被引:10
|
作者
Kameni, Aude P. W. [1 ]
Tcheumi, Herve L. [1 ,2 ]
Tonle, Ignas K. [1 ,3 ]
Ngameni, Emmanuel [1 ]
机构
[1] Univ Yaounde I, Fac Sci, Dept Chim Inorgan, Lab Chim Analyt, BP 812, Yaounde, Cameroon
[2] Univ Maroua, Ecole Natl Super Polytech Maroua, Dept Sci Environm, Lab Chim Environm, BP 46, Maroua, Cameroon
[3] Univ Dschang, Fac Sci, Dept Chim, Electrochim & Chim Mat, BP 67, Dschang, Cameroon
关键词
Anionic surfactant; Organo-LDH; Methyl parathion; para-Nitrophenol; LDH-film-modified electrode; Electroanalysis; PULSE STRIPPING VOLTAMMETRY; ONE-STEP FABRICATION; ORGANOPHOSPHATE PESTICIDES; COATED ELECTRODES; ETHYLENE-GLYCOL; IONIC LIQUID; INTERCALATION; METHYLPARATHION; NANOPARTICLES; FILM;
D O I
10.1016/j.crci.2018.11.001
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An inorganic-organic composite material was prepared by the insertion of bis(ethylhexyl)hydrogen phosphate (BEHP) within the interlayer space of a nickel-aluminum-layered double hydroxide (NiAI LDH). X-ray diffraction, thermogravimetric analysis, and Fourier transform infrared were used to characterize the pristine and modified LDH (NiAl-BEHP), which together confirm the intercalation of BEHP in the mineral structure. Cyclic voltammetry using [Fe(CN)(6)](3) as an anionic redox probe demonstrated a significant decrease in the anion exchange capacity of NiAl upon modification. Used as electrode modifier for methyl parathion (MP) detection, a remarkable increase in MP signal on NiAIBEHP-modified glassy carbon electrode (GCE/NiAl-BEHP) was observed, because of the high hydrophobicity character of the modified LDH. The signal assigned to the electroactivity of the nitro group being less stable than that of the reduction of the nitroso group, the use of both functions was explored for the calibration experiments. Sensitivities of 0.79 mu A mu M-1 and 0.14 mu A mu M-1 were obtained, with detection limits of 2.28 x 10(-8) and 12.4 x 10(-8) mol L-1 for nitro and nitroso groups, respectively. However, the linearity range was more important for the nitroso group (0.5-12 mu M) as compared to the nitro group (0.5-3.5 mu M). Moreover, the signal of the nitroso group showed poor interference with some chemical species likely to be encountered in the presence of MP. The GCE/NiAl-BEHP-modified electrode was particularly effective for the differentiation of 4-nitrophenol (4-NP) from MP. Interestingly, the decrease in the sensor sensitivity was negligible (0.13 mu A mu M-1) when the calibration curve of MP was plotted in the presence of 1 mu M of 4-NP. The poor efficiency of the sensor to quantify 4-NP was probably because of the high organophilic character of the electrode material. The developed method was successfully applied to quantify MP in spring water. (C) 2018 Academie des sciences. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:22 / 33
页数:12
相关论文
共 50 条
  • [21] Alkali-etched ultrathin NiAl-layered double hydroxides with rich vacancies for the sensitive electrochemical detection of dopamine
    Wang, Jun
    Ren, Jing
    Xu, Xinyue
    Wang, Xiaoyu
    Liu, Yajie
    Xu, Jie
    Xin, Liantao
    Zhang, Hui
    Zhan, Tianrong
    MICROCHEMICAL JOURNAL, 2024, 199
  • [22] Electrochemical Oxidation of Epinephrine and Uric Acid at a Layered Double Hydroxide Film Modified Glassy Carbon Electrode and Its Application
    Ni, Fang
    Wang, Yinling
    Zhang, Dandan
    Gao, Feng
    Li, Maoguo
    ELECTROANALYSIS, 2010, 22 (10) : 1130 - 1135
  • [23] Electrochemical determination of bisphenol A at Mg-Al-CO3 layered double hydroxide modified glassy carbon electrode
    Yin, Huanshun
    Cui, Lin
    Ai, Shiyun
    Fan, Hai
    Zhu, Lusheng
    ELECTROCHIMICA ACTA, 2010, 55 (03) : 603 - 610
  • [24] Electrochemical determination of para-nitrophenol at apatite-modified carbon paste electrode: Application in river water samples
    El Mhammedi, M. A.
    Achak, M.
    Bakasse, M.
    Chtaini, A.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 163 (01) : 323 - 328
  • [25] Efficient electrochemical detection of hazardous para-nitrophenol based on a carbon paste electrode modified with green synthesized gold/iron oxide nanocomposite
    Aisha A. Ganash
    Rahmah A. Aljubairy
    Chemical Papers, 2022, 76 : 3169 - 3183
  • [26] Efficient electrochemical detection of hazardous para-nitrophenol based on a carbon paste electrode modified with green synthesized gold/iron oxide nanocomposite
    Ganash, Aisha A.
    Aljubairy, Rahmah A.
    CHEMICAL PAPERS, 2022, 76 (05) : 3169 - 3183
  • [27] Electrochemical detection of dopamine on a Ni/Al layered double hydroxide modified carbon ionic liquid electrode
    Zhu, Zhihong
    Qu, Lining
    Guo, Yaqing
    Zeng, Yan
    Sun, Wei
    Huang, Xintang
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 151 (01): : 146 - 152
  • [28] Electrochemical detection of methyl parathion using zirconium dioxide@single-walled carbon nanotubes nanocomposite modified glassy carbon electrode
    Guo, Meimei
    Han, Jiale
    Mishchenko, Yurii
    Butenko, Andrii
    Kovalenko, Vladyslav
    Rozhkova, Tetiana
    Zhao, Hongyuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (11):
  • [29] RETRACTION: Performance of graphene-zinc oxide nanocomposite coated-glassy carbon electrode in the sensitive determination of para-nitrophenol
    Dar, Riyaz Ahmad
    Naikoo, Gowhar Ahmad
    Srivastava, Ashwini Kumar
    Ul Hassan, Israr
    Karna, Shashi P.
    Giri, Lily
    Shaikh, Ahamad M. H.
    Rezakazemi, Mashallah
    Ahmed, Waqar
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [30] Bismuth vanadate modified glassy carbon electrode for sensitive electrochemical antibiotic detection
    Timmy Unya Anak Nedy
    Mohammad Aliff bin Ali Rahman
    Ellie Yi Lih Teo
    Pang Hung Yiu
    Elisha Yiu
    Alvin Lim Teik Zheng
    Yoshito Andou
    Journal of Nanoparticle Research, 2025, 27 (4)