Design and performance evaluation of SDD based X-ray spectrometer for future planetary exploration

被引:3
|
作者
Shanmugam, M. [1 ]
Vadawale, S. [1 ]
Acharya, Y. B. [1 ]
Mishra, V. [2 ]
Patel, P. N. [2 ]
Goyal, S. K. [1 ]
机构
[1] Phys Res Lab, Ahmadabad 380009, Gujarat, India
[2] Sardar Vallabhbhai Natl Inst Technol, Surat 395007, India
关键词
Silicon Drift Detector; CSPA; X-ray spectrometer; MISSION;
D O I
10.1016/j.radmeas.2012.02.014
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Silicon Drift Detector (SDD) based X-ray spectrometer has been developed for obtaining the elemental composition of unknown samples by detecting fluorescent X-rays in the energy region 1-25 key by a non-destructive process. The use of new technology X-ray detector provides good energy resolution for detecting the elements separated with similar to 150 eV apart. Here we present the design of a complete Xray spectrometer intended for use in the future space-born experiment. The low energy threshold of <1 key and the energy resolution of similar to 150 eV at 5.9 keV, as measured from the system is comparable to the standard spectrometers available off-the-shelf. We evaluated the system performance for different signal peaking time, as well as for different input count rates and show that the performance remains stable for incident count rate up to 20,000 counts per second. We have also carried out a 'proof of concept' experiment of measuring fluorescent X-ray spectrum from various standard XRF samples from the USGS catalog irradiated by the laboratory X-ray source Am-241 with 1 mCi activity. It is shown that intensities of various characteristic X-ray lines are well correlated with the respective elemental concentrations. A specific effort has been made while designing the developed X-ray spectrometer to use electronic components which are available in space grade so that the same electronic design can be used in the upcoming planetary missions with appropriate mechanical packaging. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:375 / 382
页数:8
相关论文
共 50 条
  • [31] AN X-RAY SPECTROMETER FOR INELASTIC-SCATTERING EXPERIMENTS .3. DESIGN AND PERFORMANCE
    PATTISON, P
    SUORTTI, P
    WEYRICH, W
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 : 353 - 363
  • [32] Design and performance of AERHA, a high acceptance high resolution soft x-ray spectrometer
    Chiuzbaian, Sorin G.
    Hague, Coryn F.
    Avila, Antoine
    Delaunay, Renaud
    Jaouen, Nicolas
    Sacchi, Maurizio
    Polack, Francois
    Thomasset, Muriel
    Lagarde, Bruno
    Nicolaou, Alessandro
    Brignolo, Stefania
    Baumier, Cedric
    Luening, Jan
    Mariot, Jean-Michel
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (04):
  • [33] ARDESIA-16: a 16-channel SDD-based spectrometer for energy dispersive X-ray fluorescence spectroscopy
    Utica, G.
    Fabbrica, E.
    Carminati, M.
    Borghi, G.
    Zorzi, N.
    Ficorella, F.
    Picciotto, A.
    Allegretta, I
    Falkenberg, G.
    Fiorini, C.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (07)
  • [34] A laboratory-based double X-ray spectrometer for simultaneous X-ray emission and X-ray absorption studies
    Blachucki, Wojciech
    Czapla-Masztafiak, Joanna
    Sa, Jacinto
    Szlachetko, Jakub
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1409 - 1415
  • [35] The Planetary X-ray Emission
    Bhardwaj, Anil
    HELIOPHYSICAL PROCESSES, 2010, : 271 - 282
  • [36] Simulation of the relationship between element concentrations and X-ray yields in the Mars Exploration Rover's X-ray spectrometer
    Omand, M
    Campbell, JL
    Maxwell, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 229 (01): : 123 - 136
  • [37] The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory
    Kelley, R. L.
    Bandler, S. R.
    Doriese, W. B.
    Ezoe, Y.
    Fujimoto, R.
    Gottardi, L.
    den Hartog, R.
    den Herder, J-W
    Hoevers, H.
    Irwin, K.
    Ishisaki, Y.
    Kilbourne, C. A.
    de Korte, P.
    van der Kuur, J.
    Mitsuda, K.
    Ohashi, T.
    Piro, L.
    Porter, F. S.
    Sato, K.
    Shinozaki, K.
    Shirron, P.
    Smith, S. J.
    Takei, Y.
    Whitehouse, P.
    Yamasaki, N. Y.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 757 - +
  • [38] GERMANIUM X-RAY SPECTROMETER
    SEDOV, NY
    SHISHKINA, GA
    BEZYMYANNYKH, BM
    PERSHIKOVA, TM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (05) : 1254 - 1256
  • [39] ANALYSIS WITH AN X-RAY SPECTROMETER
    REDMOND, JC
    ANALYTICAL CHEMISTRY, 1947, 19 (04) : 285 - 285
  • [40] THE CYLINDER X-RAY SPECTROMETER
    BRENTANO, JCM
    PHYSICA, 1956, 22 (08): : 705 - 706