Coordinated Control Strategy for Grid Connected DFIG wind System under Voltage Imbalance

被引:0
|
作者
Ramalingeswar, J. T. [1 ]
Subramanian, K. [1 ]
机构
[1] VIT Univ, Sch Elect Engn, Vellore Campus, Vellore, Tamil Nadu, India
关键词
DFIG; Voltage imbalance; Co-ordinated control strategies; rotor side control; grid side control; GENERATOR; MPPT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The operational characteristic of doubly fed induction generator under voltage imbalance condition is analysed in this paper. A co-ordinated control strategy employing generator side and grid side converters is presented in this paper. The control strategy calculates the compensation unbalanced voltage which is then incorporated with the reference voltage of generator side and grid side converter in order to restrain the electro magnetic torque pulsation effectively. To validate the effectiveness of the proposed control strategy, the topology is implemented in MATLAB/Simulink for 1.5 kW DFIG grid connected system which is subjected to voltage unbalance The results obtained shows that the proposed control technique can effectively reduce the torque pulsation and stator reactive power.
引用
收藏
页码:1946 / 1951
页数:6
相关论文
共 50 条
  • [31] MPPT Control of Grid Connected DFIG at Variable Wind Speed
    Bekiroglu, Erdal
    Yazar, Muhammed Duran
    [J]. ENERGIES, 2022, 15 (09)
  • [32] Control strategy for suppressing the shafting oscillation of the grid-connected DFIG-based wind power generation system
    Yao, Jun
    Zhang, Tian
    Wang, Xuewei
    Zeng, Deyin
    Sun, Peng
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (09):
  • [33] Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition
    Zhou, Yi
    Bauer, Paul
    Ferreira, Jan A.
    Pierik, Jan
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) : 240 - 246
  • [34] Effect of AC voltage control on the stability of weak AC grid connected DFIG system
    Wang, Dong
    Hou, Yunhe
    Hu, Jiabing
    [J]. 2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 1528 - 1533
  • [35] Coordinated Control of DFIG and FSIG-Based Wind Farms Under Unbalanced Grid Conditions
    Wang, Yi
    Xu, Lie
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 367 - 377
  • [36] DFIG wind turbine grid connected for frequency and amplitude control in a smart grid
    Antonio Cortajarena, Jose
    De Marcos, Julian
    Alkorta, Patxi
    Barambones, Oscar
    Cortajarena, Jon
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS FOR SUSTAINABLE ENERGY SYSTEMS (IESES), 2018, : 362 - 369
  • [37] Control Strategy based on Virtual Synchronous Generator of DFIG-Based Wind Turbine under Unbalanced Grid Voltage
    Jiao, Yingzong
    Nian, Heng
    He, Guoqing
    [J]. 2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [38] Study on Voltage Stability and Control Strategy of Grid-Connected Wind Farm
    Liu, Xinyu
    Wu, Guofang
    Li, Xianwei
    [J]. IEEE ACCESS, 2019, 7 : 148843 - 148852
  • [39] ESS equipped DFIG wind farm with coordinated power control under grid fault conditions
    Najaty Mazgar, Farshid
    Tarafdar Hagh, Mehrdad
    Tohidi, Sajjad
    [J]. JOURNAL OF POWER ELECTRONICS, 2021, 21 (01) : 173 - 183
  • [40] ESS equipped DFIG wind farm with coordinated power control under grid fault conditions
    Farshid Najaty Mazgar
    Mehrdad Tarafdar Hagh
    Sajjad Tohidi
    [J]. Journal of Power Electronics, 2021, 21 : 173 - 183