Comparison of field and laboratory collected midwave and longwave infrared emissivity spectra/data reduction techniques

被引:23
|
作者
Salvaggio, C [1 ]
Miller, CJ [1 ]
机构
[1] Spectral Informat Technol Appl Ctr, Fairfax, VA 22033 USA
关键词
longwave; midwave; emissivity; ground truth; laboratory; spectra; spectroscopy; hyperspectral;
D O I
10.1117/12.437047
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many targets that remote sensing scientists encounter when conducting their research experiments do not lend themselves to laboratory measurement of their surface optical properties. Removal of these targets from the field can change their biotic condition, disturb the surface composition, and change the moisture content of the sample. These parameters, as well as numerous others, have a marked influence on surface optical properties such as spectral and bi-directional emissivity. This necessitates the collection of emissivity spectra in the field. The propagation of numerous devices for the measurement of midwave and longwave emissivity in the field has occurred in recent years. How good a re these devices and how does the accuracy of the spectra they produce compare to the "tried and true" laboratory devices that have been around for decades? A number of temperature/emissivity separation algorithms will be demonstrated on data collected with a field portable Fourier transform infrared (FTIR) spectrometer and the merits and resulting accuracy compared to laboratory spectra made of these identical samples. A brief look at off-nadir view geometries will also be presented to alert scientists to the possible sources of error in these spectra that may result when using sensing systems that do not look straight down on targets or when their nadir looking sensor is looking at a tilted target.
引用
收藏
页码:549 / 558
页数:10
相关论文
共 50 条
  • [41] Acoustic Nonlinearity of Granite: Comparison of Data of Field and Laboratory Experiments
    Averbakh, V. S.
    Bredikhin, V. V.
    Kon'kov, A. I.
    Lebedev, A. V.
    Manakov, S. A.
    Talanov, V. I.
    ACOUSTICAL PHYSICS, 2016, 62 (03) : 371 - 376
  • [42] Comparison of laboratory data and field performance for fills subject to hydrocompression
    Kropp, AL
    McMahon, DJ
    CONSTRUCTING AND CONTROLLING COMPACTION OF EARTH FILLS, 2000, 1384 : 197 - 208
  • [43] COMPARISON OF TWO REPRESENTATIVE LAND SURFACE TEMPERATURE AND EMISSIVITY SEPARATION METHODS FOR HYPERSPECTRAL INFRARED SPECTRORADIOMETER DATA
    Wu, Hua
    Li, Zhao-Liang
    Tang, Bo-Hui
    Tang, RongLin
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 3517 - 3520
  • [44] Comparison of corrosion rates obtained from laboratory and field data
    Ruppert, J.
    Frimmel, F.
    Baier, R.
    Binder, G.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2016, 67 (06): : 660 - 666
  • [45] Infrared Spectra of Solid-State Ethanolamine: Laboratory Data in Support of JWST Observations
    Suhasaria, T.
    Wee, S.M.
    Basalgète, R.
    Krasnokutski, S.A.
    Jäger, C.
    Perotti, G.
    Henning, Th.
    arXiv,
  • [46] Infrared spectra of solid-state ethanolamine: Laboratory data in support of JWST observations
    Suhasaria, T.
    Wee, S.M.
    Basalgète, R.
    Krasnokutski, S.A.
    Jäger, C.
    Perotti, G.
    Henning, Th.
    Astronomy and Astrophysics, 2024, 691
  • [47] A comparison of quantitative analysis techniques to discriminate intimately mixed bidirectional laboratory reflectance spectra
    Nichols, T
    Thomas, J
    Kober, W
    Velten, V
    ALGORITHMS FOR MULTISPECTRAL AND HYPERSPECTRAL IMAGERY V, 1999, 3717 : 2 - 13
  • [48] SIMULATION OF COMETARY INFRARED-SPECTRA USING LABORATORY EXTINCTION DATA OF CARBONACEOUS MATERIALS
    COLANGELI, L
    BUSSOLETTI, E
    PAPOULAR, R
    MENNELLA, V
    ICARUS, 1990, 86 (01) : 198 - 207
  • [49] Comparison of laboratory and field derived K2 values for dust collected on fabric filters
    Dennis, R.
    Dirgo, J.A.
    Filtration and Separation, 1981, 18 (05): : 394 - 396
  • [50] Practical retrieval of land surface emissivity spectra in 8-14μm from hyperspectral thermal infrared data
    Wu, Hua
    Wang, Ning
    Ni, Li
    Tang, Bo-Hui
    Li, Zhao-Liang
    OPTICS EXPRESS, 2012, 20 (22): : 24761 - 24768