Enhancement of Mass Transfer between Flue Gas and Slurry in the Wet Flue Gas Desulfurization Spray Tower

被引:35
|
作者
Chen, Zhen [1 ]
Wang, Haiming [1 ]
Zhuo, Jiankun [1 ]
You, Changfu [1 ]
机构
[1] Tsinghua Univ, Key Lab Thermal Sci & Power Engn, Minist Educ, Dept Thermal Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
POLLUTION CONTROL DEVICES; FIRED POWER-PLANTS; AIR-QUALITY; CHINA; EMISSION; MODEL; GENERATION; REMOVAL; IMPACTS; SYSTEMS;
D O I
10.1021/acs.energyfuels.7b03009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an enhancement method to improve the desulfurization performance of wet flue gas desulfurization (WFGD) by adding a flow pattern controlling (FPC) device in the spraying tower. The FPC device is characterized by a modular design and composed of FPC units that are fixed under the spraying layers of the desulfurization tower. Two kinds of FPC units, each with a different scale, are designed (i.e., unit A and unit B). The effects of the FPC unit and operational parameters on the desulfurization process are determined by experimentation. The experiments show that the FPC unit significantly improves the desulfurization performance compared to the common spraying column without an aperture plate. The flow regime significantly changes and large amounts of bubbles develop above the perforated plate in the FPC unit, which is beneficial to enhance gas liquid mass transfer. The design style and structural parameters of the FPC unit both significantly influence the desulfurization performance. According to the results, optimal desulfurization performance is achieved with four holes and an aperture ratio of 0.65 for unit B. For L/G = 10 L/m(3), the desulfurization efficiency of unit B reaches 77% (approximately 22% increase) with a pressure increase of 370 Pa. The relationship between the operational parameters and the different scale units is investigated under different test conditions. In addition, the results show that the range of improvement with the perforated plate is related to the gas liquid flow regime in the unit. Finally, we attempt to build an empirical correlation formula of each influence factor on desulfurization efficiency and pressure drop based on the experimental results.
引用
收藏
页码:703 / 712
页数:10
相关论文
共 50 条
  • [21] Reactivity of the limestone in wet flue gas desulfurization
    2005, Science Press, Beijing, China (26):
  • [22] Simulation study on novel groove separator in a dual-loop wet flue gas desulfurization spray tower
    Cui, Lin
    Lu, Jingwen
    Liu, Lifei
    Qin, Mingchen
    Dong, Yong
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2020, 15 (04)
  • [24] A concise algorithm for calculating absorption height in spray tower for wet limestone-gypsum flue gas desulfurization
    Zhu, Jie
    Ye, Shi-chao
    Bai, Jie
    Wu, Zhen-yuan
    Liu, Zhen-hua
    Yang, Yun-feng
    FUEL PROCESSING TECHNOLOGY, 2015, 129 : 15 - 23
  • [25] Modeling of ammonia-based wet flue gas desulfurization in the spray scrubber
    Yong Jia
    Qin Zhong
    Xuyou Fan
    Qianqiao Chen
    Haibo Sun
    Korean Journal of Chemical Engineering, 2011, 28
  • [26] Spray characteristics of spiral nozzles used in wet flue gas desulfurization system
    School of Civil Engineering, Southeast University, Nanjing 210096, China
    不详
    不详
    Dongnan Daxue Xuebao, 2008, 3 (493-495):
  • [27] Promoting fine particle removal in double-tower cascade wet flue gas desulfurization system by flue gas temperature reduction
    Wang, Qianwen
    Wang, Leilei
    Wu, Hao
    Yang, Hongmin
    POWDER TECHNOLOGY, 2020, 373 : 581 - 589
  • [28] Modeling of ammonia-based wet flue gas desulfurization in the spray scrubber
    Jia, Yong
    Zhong, Qin
    Fan, Xuyou
    Chen, Qianqiao
    Sun, Haibo
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (04) : 1058 - 1064
  • [29] Study on flow field optimization in wet flue gas desulfurization spray scrubber
    Guo, Rui-Tang
    Gao, Xiang
    Ding, Hong-Lei
    Luo, Zhong-Yang
    Cen, Ke-Fa
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (29): : 70 - 77
  • [30] Wet flue gas desurfurization (WFGD) slurry spray header design system
    Santavicca, J. W.
    Proceedings of the ASME Power Conference 2005, Pts A and B, 2005, : 1099 - 1105