Investigation on the start-up of low wattage metal halide lamp controlled by low-frequency square-wave ballast

被引:0
|
作者
Guo, R [1 ]
Yang, YB [1 ]
Qian, ZM [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Using conventional three-stage low-frequency square-wave electronic ballast, low-wattage MH lamps may have trouble in starting-up instantly and smoothly. This paper investigates the special starting-up characteristics of low-wattage MH lamps and presents some novel control strategy according to the lamps' special characteristics. A prototype of 70W electronic ballast with the new control circuit designs was constructed and experimental results verified the novel control strategy can greatly increase the probability for lamps to successfully start up instantly and smoothly.
引用
收藏
页码:815 / 819
页数:5
相关论文
共 50 条
  • [42] Two-Stage Low-Frequency Square-Wave-Driven Electronic Ballast for HID Lamps
    Cheng, Chun-An
    Kuog, Zheng-He
    Wu, Yung-Chine
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 738 - 743
  • [43] Single-stage high-power-factor low-frequency square-wave-driven high-intensity-discharge lamp ballast
    Cheng, Chun-An
    Cheng, Hung-Liang
    Chung, Tsung-Yuan
    Ku, Chen-Wei
    IET POWER ELECTRONICS, 2013, 6 (04) : 672 - 682
  • [44] Square-wave low-frequency modulation of the discharge current for high rate deposition of stoichiometric ceramic films
    Billard, A
    Mercs, D
    Perry, F
    Frantz, C
    SURFACE & COATINGS TECHNOLOGY, 2001, 140 (03): : 225 - 230
  • [45] LOW-FREQUENCY TRIANGULAR-SQUARE-WAVE GENERATOR
    GYORGY, B
    ELECTRONIC ENGINEERING, 1978, 50 (607): : 21 - 21
  • [46] ELECTROCUTANEOUS PAIN THRESHOLDS IN HUMANS TO LOW FREQUENCY SQUARE-WAVE PULSES
    PLUTCHIK, R
    BENDER, H
    JOURNAL OF PSYCHOLOGY, 1966, 62 (02): : 151 - &
  • [47] Low frequency square-wave voltammetry of weak acids at platinum Microelectrodes
    Bragato, C
    Daniele, S
    Baldo, MA
    ELECTROANALYSIS, 2005, 17 (15-16) : 1370 - 1378
  • [48] Investigation of low power start-up characteristics of a loop heat pipe
    Kaya, T
    Ku, JT
    Hoang, TT
    Cheung, MK
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - 1999, PTS ONE AND TWO, 1999, 458 : 799 - 804
  • [49] Design and Implementation of a Single-Stage Low-Frequency Square-Wave-Driven Electronic Ballast for HID Lamps
    Cheng, Chun-An
    Cheng, Hung-Liang
    Wu, Yung-Chine
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (01): : 3230 - 3239
  • [50] The investigation on the starting process inside a small wattage metal halide lamps and its influence on extra high frequency ballast circuit design
    Yan, W
    Hui, SYR
    LIGHT SOURCES 2004, 2004, (182): : 291 - 292