Strength of reinforced concrete columns bonded with external steel plates

被引:15
|
作者
Uy, B [1 ]
机构
[1] Univ New S Wales, Sch Civil & Environm Engn, Sydney, NSW 2052, Australia
关键词
D O I
10.1680/macr.54.1.61.40802
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Rehabilitating reinforced concrete elements using external steel plates has been applied to both beams and slabs in bridge and building construction over the last two decades. The effect of applying external steel plates increases the strength of beams and slabs. This technique can also be applied to reinforced concrete columns to increase their strength with a minimal increase in the cross-sectional dimensions of the member. This article presents an experimental programme used to ascertain the behaviour of both short and slender columns. These columns had steel plates bonded to them by the use of both bolting or gluing and bolting. A simplified theoretical model based on composite construction techniques is then presented and calibrated with the experiments to determine the strength increase and recommendations for further research are then made.
引用
收藏
页码:61 / 76
页数:16
相关论文
共 50 条
  • [31] Cyclic Shear Performance of Reinforced Concrete Columns Strengthened by External Steel Rods
    Kim, Hyeong-Gook
    Lee, Yong-Jun
    Kim, Kil-Hee
    SUSTAINABILITY, 2021, 13 (23)
  • [32] Experimental study on strengthening with bonded steel angles for reinforced concrete columns after fire
    Wang, Guofeng
    Yu, Kai
    Li, Junhua
    Qiu, Dongliang
    ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 1120 - 1126
  • [33] Tests on the Steel-Concrete Bond Strength in Steel Reinforced Concrete (SRC) Columns After Fire Exposure
    Wang, Wei-Hua
    Han, Lin-Hai
    Tan, Qing-Hua
    Tao, Zhong
    FIRE TECHNOLOGY, 2017, 53 (02) : 917 - 945
  • [34] Experimental behaviour of steel fiber high strength reinforced concrete and composite columns
    Tokgoz, Serkan
    Dundar, Cengiz
    Tanrikulu, A. Kamil
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 74 : 98 - 107
  • [35] Shear strength and behavior of tubed reinforced and steel reinforced concrete (TRC and TSRC) short columns
    Abdullah, Jasim Ali
    Zhang Sumei
    Liu Jiepeng
    THIN-WALLED STRUCTURES, 2010, 48 (03) : 191 - 199
  • [36] Prediction of deflection of high strength steel fiber reinforced concrete beams and columns
    Kara, Ilker Fatih
    Dundar, Cengiz
    COMPUTERS AND CONCRETE, 2012, 9 (02): : 133 - 151
  • [37] Seismic behavior and strength of tubed steel reinforced concrete (SRC) short columns
    Zhou, Xuhong
    Liu, Jiepeng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (07) : 885 - 896
  • [38] Seismic Performance of Steel Reinforced Ultra High-strength Concrete Columns
    贾金青
    四川大学学报(工程科学版), 2009, 41 (03) : 216 - 222+230
  • [39] Residual bond strength in steel reinforced concrete columns after fire exposure
    Tao, Zhong
    Yu, Qing
    FIRE SAFETY JOURNAL, 2012, 53 : 19 - 27
  • [40] Seismic behavior of high-strength steel reinforced concrete composite columns
    Xiao, Y
    Anderson, JC
    Yaprak, TT
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 383 - 392