Analysis of concordance between the bioelectrical impedance vector analysis and the bioelectrical impedance spectroscopy in haemodialysis patients

被引:6
|
作者
Teruel-Briones, Jose L. [1 ]
Fernandez-Lucas, Milagros [1 ]
Ruiz-Roso, Gloria [1 ]
Sanchez-Ramirez, Humberto [2 ]
Rivera-Gorrin, Maite [1 ]
Gomis-Couto, Antonio [1 ]
Rodriguez-Mendiola, Nuria [1 ]
Quereda, Carlos [1 ]
机构
[1] Hosp Univ Ramon y Cajal, Serv Nefrol, Madrid 28034, Spain
[2] Hosp Univ UANL Jose Eleuterio Gonzalez, Serv Nefrol, Monterrey, Mexico
来源
NEFROLOGIA | 2012年 / 32卷 / 03期
关键词
Bioimpedance vector analysis; Multifrequency bioimpedance spectroscopy; Haemodialysis; DRY-WEIGHT PRESCRIPTION; CHRONIC KIDNEY-DISEASE; BIOIMPEDANCE SPECTROSCOPY; MULTIFREQUENCY BIOIMPEDANCE; BODY-COMPOSITION; CLINICAL-OBSERVATIONS; DIALYSIS PATIENTS; HYDRATION STATUS; SURVIVAL; WATER;
D O I
10.3265/Nefrologia.pre2012.Feb.11309
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Analysis of concordance between the bioelectrical impedance vector analysis and the bioelectrical impedance spectroscopy in haemodialysis patients impedance spectroscopy (MF-BIS) are different and not comparable. Objective: Analyse whether the inter-method variability is due to bioelectrical variables measured by the different monitors, or rather due to the equations used to calculate body volume and mass. Another objective was to determine whether, despite the inter-method variability, the classification of hydration status by the two methods is consistent. Material and Methods: Bioelectrical impedance was measured by SF-BIVA and MF-BIS immediately before a dialysis session in 54 patients on haemodialysis. In 38 patients, the study was repeated by SF-BIVA at the end of the same dialysis session. Results: Resistance and phase angle values provided by the two monitors at a frequency of 50kHz were consistent. For resistance, variability was 1.3% and the intra-class correlation coefficient was 0.99. For phase angle, variability and the intra-class correlation coefficient were 11.5% and 0.92, respectively. The volume values for total body water, extracellular water, fat mass and body cell mass were biased, with a level of variability that would not be acceptable in clinical practice. The intra-class correlation coefficient also suggested a poor level of agreement. SF-BIVA systems define overhydration or dehydration as a vector below or above the tolerance ellipse of 75% on the longitudinal axis. MF-BIS uses two criteria for pre-dialysis hyper-hydration: overhydration (OH) greater than 2.5 litres, or greater than 15% of extracellular water. The degree of equivalence with the results of the SF-BIVA monitor was better with the second criterion (kappa: 0.81, excellent agreement) than with the first one (kappa: 0.71, acceptable agreement). The MF-BIS system defines post-dialysis normal hydration as a difference between OH and ultrafiltratation volume between -1.1 and 1.1 litres and agreement with the SF-BIVA system for this parameter was acceptable (weighted kappa index: 0.64). Conclusions: The MF-BIS and SF-BIVA systems provide similar readings for bioelectrical parameters, and the wide variation in the quantification of volume and body mass must be attributed to the different equations used for calculation. Furthermore, the criteria used by both systems to define both pre- and post-dialysis hydration have an acceptable level of equivalence.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [41] Bioelectrical impedance analysis in patients with posterior vitreous detachment
    Di Marco, E.
    Di Marino, M.
    Lombardo, M.
    Capria, G.
    Aloe, G.
    Mancino, R.
    Aiello, F.
    Nucci, C.
    De Lorenzo, A.
    Cesareo, M.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (15) : 7316 - 7323
  • [42] Bioelectrical impedance spectroscopy in health and disease -: Correspondence between whole body and segmental bioelectrical impedance spectroscopy indices in patients with classical dengue fever
    Mazariegos, M
    Klassen, P
    Solomons, NW
    Fürst, P
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 205 - 209
  • [43] Bioelectrical Impedance Vector Analysis (BIVA) and Somatotype in Female Rugby Players
    Silleras, Beatriz de Mateo
    Ares, Guillermo Casas
    Marcos, Sandra de la Cruz
    Enciso, Laura Carreno
    Fernandez, Emiliano Quinto
    del Rio, Paz Redondo
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [44] Combined evaluation of nutrition and hydration in dialysis patients with bioelectrical impedance vector analysis (BIVA)
    Piccoli, Antonio
    Codognotto, Marta
    Piasentin, Paola
    Naso, Agostino
    [J]. CLINICAL NUTRITION, 2014, 33 (04) : 673 - 677
  • [45] Cachexia assessed by Bioelectrical Impedance Vector Analysis in chronic stable heart failure patients
    Ebner, NNicole
    Valentova, M.
    Bekfani, T.
    Elsner, S.
    Steinbeck, L.
    Sandek, A.
    Scherbakov, N.
    Anker, S. D.
    Doehner, W.
    Von Haehling, S.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 150 - 150
  • [46] Bioelectrical Impedance Vector Analysis (BIVA) for the monitoring of body composition in pregnancy
    Moroni, A.
    Varde, C.
    Giustetto, A.
    Stagi, S.
    Marini, E.
    Cremasco, M. Micheletti
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2022, 76 (04) : 604 - 609
  • [47] Is bioelectrical impedance vector analysis of value in the elderly with malnutrition and impaired functionality?
    Norman, Kristina
    Smoliner, Christine
    Valentini, Luzia
    Lochs, Herbert
    Pirlich, Matthias
    [J]. NUTRITION, 2007, 23 (7-8) : 564 - 569
  • [48] Bioelectrical Impedance Vector Analysis (BIVA) for the monitoring of body composition in pregnancy
    A. Moroni
    C. Vardè
    A. Giustetto
    S. Stagi
    E. Marini
    M. Micheletti Cremasco
    [J]. European Journal of Clinical Nutrition, 2022, 76 : 604 - 609
  • [49] Bioimpedance Patterns and Bioelectrical Impedance Vector Analysis (BIVA) of Body Builders
    Petri, Cristian
    Micheli, Matteo Levi
    Izzicupo, Pascal
    Timperanza, Niccolo
    Lastrucci, Tommaso
    Vanni, Daniele
    Gulisano, Massimo
    Mascherini, Gabriele
    [J]. NUTRIENTS, 2023, 15 (07)
  • [50] Bioelectrical Impedance Vector Analysis of Young Elite Team Handball Players
    Di Credico, Andrea
    Gaggi, Giulia
    Vamvakis, Anastasios
    Serafini, Sofia
    Ghinassi, Barbara
    Di Baldassarre, Angela
    Izzicupo, Pascal
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (24)