Influence of wall friction on flow regimes and scale-up of counter-current swirl spray dryers

被引:17
|
作者
Francia, Victor [1 ,2 ]
Martin, Luis [2 ]
Bayly, Andrew E. [2 ]
Simmons, Mark J. H. [1 ]
机构
[1] Univ Birmingham, Sch Chem Engn, Birmingham B15 2TT, W Midlands, England
[2] Procter & Gamble R&D, Newcastle Innovat Ctr, Newcastle Upon Tyne, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
Spray drying; Vortex flow; Scale up; Roughness; Recirculation; Swirl decay; VORTEX LENGTH; GAS; CYCLONE; SIMULATION; MODEL; DECAY; AGGLOMERATION; PERFORMANCE; MECHANISMS; EFFICIENCY;
D O I
10.1016/j.ces.2015.04.039
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The structure of the vortex flow in swirl spray dryers is investigated after having fouled the walls with deposits typical of detergent manufacture. The range of Re and swirl intensity Omega characteristic of industry are studied using three counter-current units of varying scale and design. The friction with the deposits increases the flow turbulence kinetic energy and causes a drastic attenuation of the swirl and as a result, the vortex breaks down in the chamber forming recirculation regions (i.e. areas of reverse flow). Three flow regimes (1) no recirculation, (2) central and (3) annular recirculation have been identified depending on the swirl intensity. New control and scale up strategies are proposed for swirl dryers based in predicting the decay and the flow regime using the unit geometry (i.e. initial swirl intensity Omega(i)) and experimental decay rates function of the coverage and thickness of deposits. The impact in design and numerical modelling must be stressed. Adequate prediction of the swirl is vital to study fouling and recirculation, which surely play an important part in the dispersion and aggregation of the solid phase. Current models have no means to replicate these phenomena, and yet, in this case neglecting the deposits and assuming smooth walls would result in (a) over-prediction of swirl velocity up to 40-186% (b) under-prediction of turbulent kinetic energy up to 67-85% and (c) failure to recognise recirculation areas. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.orgflicenses/by/4.0/).
引用
收藏
页码:399 / 413
页数:15
相关论文
共 48 条
  • [41] Numerical modeling of water oil two-phase flow during counter-current spontaneous imbibition in porous media at pore-scale
    Jafari, Iman
    Rokhforouz, Mohammad-Reza
    PETROLEUM SCIENCE AND TECHNOLOGY, 2020, 38 (24) : 1040 - 1053
  • [42] Effect of Wall Compliance and Permeability on Blood-Flow Rate in Counter-Current Microvessels Formed From Anastomosis During Tumor-Induced Angiogenesis
    Guo, Peng
    Fu, Bingmei M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (04):
  • [43] Pore-scale interfacial dynamics and oil-water relative permeabilities of capillary driven counter-current flow in fractured porous media
    Gunde, Akshay
    Babadagli, Tayfun
    Roy, Susanta Sinha
    Mitra, Sushanta Kumar
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2013, 103 : 106 - 114
  • [44] SCALE-UP EFFECTS DUE TO NEAR-WALL CHANNELING IN ISOTHERMAL ADSORPTION COLUMNS - ON THE LIMITATIONS IN THE USE OF PLUG FLOW MODELS
    TOBIS, J
    VORTMEYER, D
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1991, 29 (03) : 147 - 153
  • [45] THEORETICAL STUDY OF COUNTER-CURRENT LIQUID-VAPOR FLOW UNDER CONDENSATION CONDITIONS OVER NON-ISOTHERMAL VERTICAL WALL OF TWO-PHASE CLOSED THERMOSYPHON
    Zolfagharroshan, Mohammad
    Xu, Minghan
    Zueter, Ahmad
    Sasmito, Agus
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 10, 2023,
  • [46] Membrane-Current Collector-Based Flow-Electrode Capacitive Deionization System: A Novel Stack Configuration for Scale-Up Desalination
    Xu, Longqian
    Mao, Yunfeng
    Zong, Yang
    Peng, Shuai
    Zhang, Xiaomeng
    Wu, Deli
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (19) : 13286 - 13296
  • [47] Interfacial behavior of the air-water counter-current two-phase flow in a 1/30 scale-down of pressurized water reactor (PWR) hot leg
    Badarudin, Apip
    Setyawan, Andriyanto
    Dinaryanto, Okto
    Widyatama, Arif
    Indarto
    Deendarlianto
    ANNALS OF NUCLEAR ENERGY, 2018, 116 : 376 - 387
  • [48] Efficient oxygen reduction to alkaline peroxide at current densities up to 500 mA cm-2 on a gas diffusion electrode with hydrophobic carbon microporous layer: Influence of fluid dynamics and reactor operation on scale-up
    Bashir, Shahid M.
    Gyenge, Elod L.
    CHEMICAL ENGINEERING JOURNAL, 2024, 494