Research on the Traceability of Absolute Optical Fiber Power to Cryogenic Radiometer

被引:0
|
作者
Xu, Nan [1 ]
Li, Jianwei [1 ]
Gan, Haiyong [1 ]
Zhang, Zhixin [1 ]
机构
[1] Natl Inst Metrol, Beijing 100029, Peoples R China
关键词
TRANSFER STANDARD; CALIBRATION;
D O I
10.1117/12.2199645
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical fiber power is an important physical quantity for optical fiber communication measurement. Currently, the absolute optical fiber power is traceable to absolute radiometer, such as electrically calibrated radiometer, and cryogenic radiometer. For optical fiber power transfer, the primary standard of NIM is the cryogenic radiometer that has an uncertainty of 2 parts in 10(4). Because most cryogenic radiometers are designed to be used with collimated beams rather than divergent beams from an optical fiber; therefore transfer standards should be well designed for optical power measurement using the beam geometry correction. We designed a trap detector using for optical fiber power transfer. One can omit the beam geometry correction from an optical fiber using his design. We present a fiber power measurement using a planar detector compared with this trap detector, which are traceable to the primary standard (cryogenic radiometer). The difference between the comparison shows that the trap detector is suitable for absolute fiber power measurement, meanwhile optical fiber power transfer using planar detectors should be corrected when transferred from cryogenic radiometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Experimental Study on Traceability of Absolute Radiometer to Cryogenic Radiometer
    Zhang Junchao
    Xu Nan
    Xu Ning
    Meng Haifeng
    Liu Wende
    Cai Chuan
    Zhang Bifeng
    Man Shuai
    Wang Meng
    Li Yinliang
    Xiong Limin
    ACTA OPTICA SINICA, 2022, 42 (05)
  • [2] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Çelikel, O
    Bazkir, Ö
    Küçükoglu, M
    Samedov, F
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (06) : 529 - 543
  • [3] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Oğuz Çelikel
    Özcan Bazkir
    Mehmet Küçükoğlu
    Farhad Samedov
    Optical and Quantum Electronics, 2005, 37 : 529 - 543
  • [4] Space Cryogenic Absolute Radiometer
    Wu D.
    Wang K.
    Ye X.
    Wang Y.-P.
    Fang W.
    Faguang Xuebao/Chinese Journal of Luminescence, 2019, 40 (08): : 1015 - 1021
  • [5] Absolute cryogenic radiometer for high accuracy optical radiant power measurement in a wide spectral range
    Gan, Haiyong
    He, Yingwei
    Liu, Xiangliang
    Xu, Nan
    Wu, Houping
    Feng, Guojin
    Liu, Wende
    Lin, Yandong
    CHINESE OPTICS LETTERS, 2019, 17 (09)
  • [6] Absolute cryogenic radiometer for high accuracy optical radiant power measurement in a wide spectral range
    甘海勇
    赫英威
    刘想靓
    徐楠
    吴厚平
    冯国进
    刘文德
    林延东
    ChineseOpticsLetters, 2019, 17 (09) : 54 - 58
  • [7] OPTICAL POWER CALIBRATOR BASED ON A STABILIZED GREEN HE-NE-LASER AND A CRYOGENIC ABSOLUTE RADIOMETER
    VARPULA, T
    SEPPA, H
    SAARI, JM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (02) : 558 - 564
  • [8] A CRYOGENIC RADIOMETER FOR ABSOLUTE RADIOMETRIC MEASUREMENTS
    MARTIN, JE
    FOX, NP
    KEY, PJ
    METROLOGIA, 1985, 21 (03) : 147 - 155
  • [9] CRYOGENIC SOLAR ABSOLUTE RADIOMETER (CSAR)
    MARTIN, JE
    FOX, NP
    METROLOGIA, 1993, 30 (04) : 305 - 308
  • [10] INTERCOMPARISON BETWEEN THE NIST LBIR ABSOLUTE CRYOGENIC RADIOMETER AND AN OPTICAL TRAP DETECTOR
    LORENTZ, SR
    DATLA, RU