Surgical Approach and Hip Laterality Affect Accuracy of Acetabular Component Placement in Primary Total Hip Arthroplasty

被引:0
|
作者
Crawford, David A. [1 ]
Adams, Joanne B. [2 ]
Hobbs, Gerald R. [3 ]
Lombardi, Adolph V., Jr. [2 ,4 ,5 ,6 ]
Berend, Keith R. [2 ,4 ,5 ]
机构
[1] Joint Implant Surg, New Albany, OH 43054 USA
[2] Joint Implant Surg Inc, New Albany, OH USA
[3] West Virginia Univ, Dept Stat, Morgantown, WV USA
[4] White Fence Surg Suites, New Albany, OH USA
[5] Mt Carmel Hlth Syst, Columbus, OH USA
[6] Ohio State Univ, Dept Orthopaed, Wexner Med Ctr, Columbus, OH USA
关键词
DIRECT ANTERIOR APPROACH; MEASURING CUP ORIENTATION; INTRAOPERATIVE FLUOROSCOPY; POSTERIOR APPROACH; LEARNING-CURVE; SAFE ZONE; POSITION; REPLACEMENT; ANTEVERSION; DISLOCATIONS;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Controversy remains if the anterior approach improves acetabular component alignment, and many studies have compared approaches with different surgeons over different timeframes. The purpose of this study was to assess a single surgeon's experience over a one-year timeframe and radiographically compare acetabular component positioning with the direct anterior versus direct lateral approach. Secondarily, this study compares acetabular component position differences between right and left hips for a right-hand dominant surgeon. Materials and Methods: Postoperative radiographs of 289 primary total hip arthroplasties (THAs) performed by a single right-hand dominant surgeon in 2014 were reviewed for abduction, anteversion, and medial cup seating. Component position was compared to surgical approach with 152 direct anterior (DA) THAs (53%) and 137 direct lateral (DL) THAs (47%). The operative side was also compared to surgeon hand dominance. Surgeons target was 40 degrees abduction, 20 degrees anteversion +/- 5 degrees, and seating to the teardrop +/- 5mm. Lewinnek target was also assessed. Results: DA hips had a significantly lower abduction angle (p=0.04), less abduction target outliers (p<0.001), less abduction Lewinnek outliers (p<0.001), less target anteversion outliers (p<0.001), closer seating to teardrop (p<0.001), and less seating outliers (p<0.001). The combined target and Lewinnek safe zone were achieved more often in DA (p<0.001, p=0.042). Controlling for body mass index (BMI), the combined target achievement remained significantly better for DA (p=0.02), but combined Lewinnek was not significant (p=0.07). In the DA approach, right hips had a significantly lower abduction angle (p=0.03), less Lewinnek anteversion outliers (p=0.043), and less combined Lewinnek outliers (p=0.027). In the DL group, right hips had significantly higher anteversion angles (p=0.004) and Lewinnek anteversion outliers (p=0.033). Conclusion: The anterior approach improved target abduction, anteversion, and medialization compared to the direct lateral approach. Significant differences in component positioning were found in both approaches based on the surgeons dominant and non-dominant side.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 22
  • [22] Effect of Acetabular Component Positioning on Functional Outcomes in Primary Total Hip Arthroplasty
    Goyal, Prateek
    Lau, Adrian
    Naudie, Douglas D.
    Teeter, Matthew G.
    Lanting, Brent A.
    Howard, James L.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03): : 843 - 848
  • [23] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [24] Accuracy and Precision of Version Angle Measurements of the Acetabular Component After Total Hip Arthroplasty
    Nishino, Hanae
    Nakamura, Shigeru
    Arai, Noriyuki
    Matsushita, Takashi
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1644 - 1647
  • [25] Redefining the Acetabular Component Safe Zone for Posterior Approach Total Hip Arthroplasty
    Danoff, Jonathan R.
    Bobman, Jacob T.
    Cunn, Gregory
    Murtaugh, Taylor
    Gorroochurn, Prakash
    Geller, Jeffrey A.
    Macaulay, William
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02): : 506 - 511
  • [26] CEMENTLESS FIXATION OF THE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    DEKLERK, AJ
    BOMBELLI, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03): : 447 - 447
  • [27] Acetabular component orientation in total hip arthroplasty: the impact of obesity
    McArthur, Benjamin A.
    Vulcano, Ettore
    Cross, Michael
    Nguyen, Joseph
    Della Valle, Alejandro G.
    Salvati, Eduardo
    HIP INTERNATIONAL, 2014, 24 (03) : 263 - 269
  • [28] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [29] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [30] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Fırat Ozan
    Murat Kahraman
    Ali Baktır
    Kürşat Gençer
    Journal of Orthopaedic Surgery and Research, 16