Electrochemical Detection of Bacillus anthracis Protective Antigen Gene Using DNA Biosensor Based on Stem-Loop Probe

被引:16
|
作者
Ziolkowski, Robert [1 ]
Oszwaldowski, Slawomir [2 ]
Zacharczuk, Katarzyna [3 ]
Zasada, Aleksandra Anna [4 ]
Malinowska, Elzbieta [1 ,5 ]
机构
[1] Warsaw Univ Technol, Inst Biotechnol, Fac Chem, Chair Med Biotechnol, PL-00664 Warsaw, Poland
[2] Warsaw Univ Technol, Fac Chem, Chair Analyt Chem 7, PL-00664 Warsaw, Poland
[3] Natl Inst Hyg, Dept Bacteriol, Natl Inst Publ Hlth, PL-00791 Warsaw, Poland
[4] Natl Inst Hyg, Dept Sera & Vaccines Evaluat, Natl Inst Publ Hlth, PL-00791 Warsaw, Poland
[5] CEZAMAT PW, PL-00644 Warsaw, Poland
关键词
SEQUENCE-SPECIFIC DETECTION; REAGENTLESS; DISEASE;
D O I
10.1149/2.0551805jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The presented study is focused on the development of repetitive, fast and versatile "on-off" signaling electrochemical genosensor for detection of pagA gene of Bacillus anthracis. Such a sensor will be further used in the portable devices dedicated to molecular diagnostic. The DNA molecular beacon probe was immobilized onto gold electrodes in its folded state through the alkanethiol linker at the 5'-end, while the 3'-end was labeled with methylene blue redox molecule. Initial optimization was conducted for HPLC purified cDNA. Nonetheless application of such prepared biosensor for unpurified PCR product required further investigations. As the sensor response was significantly dependent on the stem-loop architecture, the three different hairpin probes were analyzed. The detected sequence was interior to amplicon, identical as in case of cDNA. The developed "on-off" genosensor allows for detection, in 5 minute, the pagA gene sequence at the level of 5.7 nM with 22.9-86.0 nM linear detection range also in the great excess of other DNA presented in the sample. Both LOD and linear range were significantly improved in case of longer assay time. The biosensor proved its applicability also in detection of pagA gene of Bacillus anthracis in PCR samples amplified with reduced number of cycles. (C) 2018 The Electrochemical Society.
引用
收藏
页码:B187 / B195
页数:9
相关论文
共 50 条
  • [21] Surface Plasmon Resonance Biosensor for Detection of Bacillus anthracis, the Causative Agent of Anthrax from Soil Samples Targeting Protective Antigen
    N. Ghosh
    G. Gupta
    M. Boopathi
    V. Pal
    A. K. Singh
    N. Gopalan
    A. K. Goel
    Indian Journal of Microbiology, 2013, 53 : 48 - 55
  • [22] DETECTION OF BACILLUS ANTHRACIS PROTECTIVE ANTIGEN BY ENZYME-IMMUNOASSAY USING POLYCLONAL AND MONOCLONAL-ANTIBODIES
    KLEINEALBERS, C
    BOHM, R
    JOURNAL OF VETERINARY MEDICINE SERIES B-ZENTRALBLATT FUR VETERINARMEDIZIN REIHE B-INFECTIOUS DISEASES AND VETERINARY PUBLIC HEALTH, 1989, 36 (03): : 226 - 230
  • [23] Electrochemical detection of the binding of Bacillus anthracis protective antigen (PA) to the membrane receptor on macrophages through release of nitric oxide
    Trouillon, Raphael
    Williamson, E. Diane
    Saint, Richard J.
    O'Hare, Danny
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 138 - 144
  • [24] Detection of unlabeled nucleic acids using stem-loop probe with universal reporter and dual-quencher
    Huang, Liming
    Hunter, Kenneth W., Jr.
    Publicover, Nelson G.
    Tam-Chang, Suk-Wah
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [25] Electrochemical detection of bacterial 16S rRNA gene using a biosensor based on poly-adenine tailed DNA probe
    Li, Lanying
    Li, Yan
    Wen, Yanli
    Wang, Lele
    Liang, Wen
    Yang, Xue
    Meng, Jiaoran
    Duan, Manlei
    Ding, Min
    Liu, Gang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [26] Electrochemical DNA sensors based on redox-labeled stem-loop probes in polymeric nanoporous films
    Harandizadeh, Zeinab
    Ito, Takashi
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [27] Novel stem-loop probe DNA arrays: Detection of specific acetotrophic 16S ribosomal RNA signatures
    Boateng, Jonas
    Zahorchak, Robert
    Peek, Joel
    Chittur, Krishnan
    ANALYTICAL BIOCHEMISTRY, 2013, 435 (01) : 60 - 67
  • [28] Electrochemical biosensor for the detection of a sequence of the TP 53 gene using a methylene blue lab elle d DNA probe #
    Otero, Fernando
    Shortall, Kim
    Salaj-Kosla, Urszula
    Tofail, Syed A. M.
    Magner, Edmond
    ELECTROCHIMICA ACTA, 2021, 388
  • [29] Nanoparticle-Based Biobarcoded DNA Sensor for the Rapid Detection of pagA Gene of Bacillus Anthracis
    Zhang, Deng
    Anderson, Michael J.
    Huarng, Michael C.
    Alocilja, Evangelyn C.
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2011, 10 (06) : 1433 - 1438
  • [30] Further insight into the possible influence of electrode blocking agents on the stem-loop based electrochemical DNA sensor parameters
    Szymczyk, Anna
    Soliwodzka, Karolina
    Moskal, Magdalena
    Różanowski, Krzysztof
    Ziólkowski, Robert
    Sensors and Actuators B: Chemical, 2022, 354