Quantitative, Simultaneous PET/MRI for Intratumoral Imaging with an MRI-Compatible PET Scanner

被引:23
|
作者
Ng, Thomas S. C. [1 ]
Bading, James R. [2 ]
Park, Ryan [3 ]
Sohi, Hargun [1 ]
Procissi, Daniel [1 ]
Colcher, David [2 ]
Conti, Peter S. [3 ]
Cherry, Simon R. [4 ]
Raubitschek, Andrew A. [2 ]
Jacobs, Russell E. [1 ]
机构
[1] CALTECH, Biol Imaging Ctr, Beckman Inst, Pasadena, CA 91125 USA
[2] Beckman Res Inst City Hope, Dept Canc Immunotherapeut & Tumor Immunol, Duarte, CA USA
[3] Univ So Calif, Keck Sch Med, Mol Imaging Ctr, Dept Radiol, Los Angeles, CA 90033 USA
[4] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
PET/MRI; multimodal imaging; tumor heterogeneity; quantitative molecular imaging; preclinical; POSITRON-EMISSION-TOMOGRAPHY; PERFORMANCE EVALUATION; IN-VIVO; MODEL;
D O I
10.2967/jnumed.111.099861
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noninvasive methods are needed to explore the heterogeneous tumor microenvironment and its modulation by therapy. Hybrid PET/MRI systems are being developed for small-animal and clinical use. The advantage of these integrated systems depends on their ability to provide MR images that are spatially coincident with simultaneously acquired PET images, allowing combined functional MRI and PET studies of intratissue heterogeneity. Although much effort has been devoted to developing this new technology, the issue of quantitative and spatial fidelity of PET images from hybrid PET/MRI systems to the tissues imaged has received little attention. Here, we evaluated the ability of a first-generation, small-animal MRI-compatible PET scanner to accurately depict heterogeneous patterns of radiotracer uptake in tumors. Methods: Quantitative imaging characteristics of the MRI-compatible PET (PET/MRI) scanner were evaluated with phantoms using calibration coefficients derived from a mouse-sized linearity phantom. PET performance was compared with a commercial small-animal PET system and autoradiography in tumor-bearing mice. Pixel and structure-based similarity metrics were used to evaluate image concordance among modalities. Feasibility of simultaneous PET/MRI functional imaging of tumors was explored by following Cu-64-labeled antibody uptake in relation to diffusion MRI using cooccurrence matrix analysis. Results: The PET/MRI scanner showed stable and linear response. Activity concentration recovery values (measured and true activity concentration) calculated for 4-mm-diameter rods within linearity and uniform activity rod phantoms were near unity (0.97 +/- 0.06 and 1.03 +/- 0.03, respectively). Intratumoral uptake patterns for both F-18-FDG and a Cu-64-antibody acquired using the PET/MRI scanner and small-animal PET were highly correlated with autoradiography (r > 0.99) and with each other (r = 0.97 +/- 0.01). On the basis of these data, we performed a preliminary study comparing diffusion MRI and radiolabeled antibody uptake patterns over time and visualized movement of antibodies from the vascular space into the tumor mass. Conclusion: The MRI-compatible PET scanner provided tumor images that were quantitatively accurate and spatially concordant with autoradiography and the small-animal PET examination. Cooccurrence matrix approaches enabled effective analysis of multimodal image sets. These observations confirm the ability of the current simultaneous PET/MRI system to provide accurate observations of intratumoral function and serve as a benchmark for future evaluations of hybrid instrumentation.
引用
收藏
页码:1102 / 1109
页数:8
相关论文
共 50 条
  • [31] Hybrid MRI/PET of the heart: a new complementary imaging technique for simultaneous acquisition of MRI and PET data
    Schlosser, Thomas
    Nensa, Felix
    Mahabadi, Amir A.
    Poeppel, Thorsten D.
    [J]. HEART, 2013, 99 (05) : 351 - 352
  • [32] Simultaneous FET-PET and fMRI in brain tumors using a PET/MRI hybrid scanner
    Herzog, Hans
    Stoffels, Gabriele
    Kaffanke, Joachim
    Tellmann, Lutz
    Weirich, Christoph
    Kops, Elena Rota
    Neuner, Irene
    Scheins, Juergen
    Shah, Nadim
    Langen, Karl
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [33] Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
    Slipsager, Jakob M.
    Ellegaard, Andreas H.
    Glimberg, Stefan L.
    Paulsen, Rasmus R.
    Tisdall, M. Dylan
    Wighton, Paul
    van der Kouwe, Andre
    Marner, Lisbeth
    Henriksen, Otto M.
    Law, Ian
    Olesen, Oline V.
    [J]. PLOS ONE, 2019, 14 (04):
  • [34] Workflow in Simultaneous PET/MRI
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (04) : 332 - 344
  • [35] Simultaneous PET/MR imaging results of a rat brain and a mouse heart with an MRI compatible PET detector in a 9.4 T microMRI
    Maramraju, Harsha
    Smith, S. David
    Stoll, Sean
    Schulz, Daniela
    Purschke, Martin
    Ravindranath, Bosky
    Junnarkar, Sachin
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [36] Development of MRI-Compatible Nuclear Medicine Imaging Detectors
    Wagenaar, D. J.
    Nalcioglu, O.
    Muftuler, L. T.
    Szawlowski, M.
    Kapusta, M.
    Pavlov, N.
    Meier, D.
    Maehlum, G.
    Patt, B. E.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1825 - 1828
  • [37] State of the Art in Quantitative Imaging in CT, PET and MRI
    McNitt-Gray, M.
    Kinahan, P.
    Jackson, E.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3862 - 3863
  • [38] Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system
    Yamamoto, Seiichi
    Watabe, Tadashi
    Watabe, Hiroshi
    Aoki, Masaaki
    Sugiyama, Eiji
    Imaizumi, Masao
    Kanai, Yasukazu
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : N1 - N13
  • [39] An MRI-compatible PET Insert for Whole Body Studies in Rodents at High Functional and Anatomical Resolution
    Vaska, P.
    Purschke, M. L.
    Fried, J.
    Junnarkar, S. S.
    Gualtieri, E.
    Pickup, S.
    Karp, J. S.
    Stoll, S.
    Maramraju, S. -H.
    Ravindranath, B.
    Budassi, M.
    Cao, T.
    Pratte, J. -F.
    O'Connor, P.
    Schlyer, D.
    Woody, C. L.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3169 - 3172
  • [40] PET, MRI, and simultaneous PET/MRI in the development of diagnostic and therapeutic strategies for glioma
    Puttick, Simon
    Bell, Christopher
    Dowson, Nicholas
    Rose, Stephen
    Fay, Michael
    [J]. DRUG DISCOVERY TODAY, 2015, 20 (03) : 306 - 317