A dosimetric study using split x-jaw planning technique for the treatment of endometrial carcinoma

被引:5
|
作者
Keil, Jeanette [1 ]
Carda, Joanne [2 ]
Reihart, Jade [3 ]
Seidel, Marjorie [1 ]
Lenards, Nishele [4 ]
Hunzeker, Ashley [4 ]
机构
[1] MedStar RadAmer, Dept Radiat Oncol, 9105 Franklin Sq Dr,Suite 100, Baltimore, MD 21237 USA
[2] Fairview Range Med Ctr, Dept Radiat Oncol, Hibbing, MN 55746 USA
[3] Advocate Lutheran Gen Hosp, Dept Radiat Oncol, Park Ridge, IL 60068 USA
[4] Univ Wisconsin, Med Dosimetry Program, La Crosse, WI 54601 USA
关键词
Split x-jaw planning technique; Volumetric modulated arc radiotherapy; Large planning target volume; Varian multileaf collimator; Endometrial radiation therapy;
D O I
10.1016/j.meddos.2020.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this retrospective study was to determine if the split x-jaw planning technique could be used with Varian linear accelerators to improve plan conformity and limit dose to organs at risk (OAR) for planning target volumes that require field sizes larger than the 15 cm extent of the multileaf collimator in the x-jaw position. Traditional planning techniques include limited and open x-jaw methods. The study population included 20 randomly selected patients with endometrial carcinoma. Treatment plans for each patient were designed using split, limited, and open x-jaw volumetric modulated arc radiotherapy for comparison purposes. Dose statistics including the PTV conformity index and dose to OAR were used to evaluate plan performance. The split x-jaw planning method had the most consistent conformity index (0.98 +/- 0.02), followed by the open (01 +/- 0.03), and the limited (1.04 +/- 0.05) techniques. On average, the split method better spared the OAR. In comparison to the limited and open techniques, the split method reduced the dose to the bowel by 3.8%, rectum by 3.2%, sigmoid by 2.1%, right femoral head by 3.5%, and left femoral head by 3.9%. The split and open techniques showed comparable bladder results and were superior over the limited method. The monitor units were highest with the split method leading to increased treatment times. The split x-jaw planning technique should be used with Varian linear accelerators to produce superior volumetric modulated arc radiotherapy plans for planning target volumes larger than the maximum extent of the multileaf collimator in the x-jaw direction. (C) 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:278 / 283
页数:6
相关论文
共 50 条
  • [31] Configuration of a treatment planning system: study and dosimetric evaluation for treatments with small fields
    Lobefalo, F.
    Fogliata, A.
    Reggiori, G.
    Stravato, A.
    Cozzi, L.
    Pimpinella, M.
    Palumbo, V.
    Mancosu, P.
    Gaudino, A.
    Scorsetti, M.
    Tomatis, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S413 - S414
  • [32] DOSIMETRIC VERIFICATION OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS: RESULTS OF IAEA PILOT STUDY
    Gershkevitsh, E.
    Schmidt, R.
    Velez, G.
    Miller, D.
    Korf, E.
    Yip, F.
    Wanwilairat, S.
    Vatnitsky, S.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S115 - S115
  • [33] Dosimetric comparison of inhomogeniety corrections in IMRT treatment planning systems: A collaborative study
    Mitra, R
    Bagala, T
    Olch, A
    Das, I
    Cheng, C
    Chopra, K
    Hasson, B
    Jiang, Z
    Murphy, S
    Lian, J
    Ahnesjo, A
    MEDICAL PHYSICS, 2005, 32 (06) : 1965 - 1965
  • [34] Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
    Gershkevitsh, Eduard
    Schmidt, Rainer
    Velez, Graciela
    Miller, Dan
    Korf, Erhardt
    Yip, Fernando
    Wanwilairat, Somsak
    Vatnitsky, Stanislav
    RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) : 338 - 346
  • [35] Electron Are Therapy for Bilateral Chest Wall Irradiation: Treatment Planning and Dosimetric Study
    Sharma, P. K.
    Munshi, A.
    Budrukkar, A.
    Jamema, S. V.
    Tambe, C. M.
    Jalali, R.
    Sarin, R.
    Deshpande, D. D.
    Shrivastava, S. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S718 - S719
  • [36] In-vivo dosimetric evaluation of an atlas based labeling technique using MR DIXON for MR-only RT treatment planning
    Frantzen-Steneker, M.
    Helle, M.
    Schulz, H.
    Renisch, S.
    Schadewaldt, N.
    Wolf, A.
    Rozendaal, R.
    Van Kranen, S.
    Alpay, E.
    Van der Heide, U.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S104 - S104
  • [37] STUDY OF HISTOPATHOLOGICAL MODIFICATIONS OBSERVED IN TREATMENT OF ENDOMETRIAL CARCINOMA WITH LYNESTRENOL
    LEJEUNE, B
    WILKIN, P
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 1977, 6 (08): : 1159 - 1169
  • [38] PROGNOSIS AND TREATMENT OF ENDOMETRIAL CARCINOMA - RETROSPECTIVE STUDY OF 418 CASES
    SHENYI, L
    ENYU, W
    CHIMING, L
    JINGXIAN, L
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 1989, 8 (04) : 236 - 245
  • [39] Dosimetric advantage of HyperArc over an institutional RapidArc planning technique for stereotactic treatment of multiple brain metastases
    Basharat, Fateen
    Dekker, Kurtis
    Olding, Tim
    Alexander, Kevin
    Kerr, Andrew
    MEDICAL PHYSICS, 2024, 51 (08) : 5786 - 5786
  • [40] DIAGNOSIS OF ENDOMETRIAL CARCINOMA USING THE MI-MARKR HELIX SAMPLING TECHNIQUE