Provisions for Ductile Behavior of Timber-to-Steel Connections with Multiple Glued-In Rods

被引:30
|
作者
Parida, Gabriela [1 ]
Johnsson, Helena [1 ]
Fragiacomo, Massimo [2 ]
机构
[1] Lulea Univ Technol, Dept Civil Environm & Nat Resources Engn, S-97187 Lulea, Sweden
[2] Univ Sassari, Dept Architecture Design & Urban Planning, I-07041 Alghero, Italy
关键词
Timber construction; Laminated materials; Anchorages; Rods; Adhesives; Ductility; Beam columns; Beam column; STRENGTH; ADHESIVE;
D O I
10.1061/(ASCE)ST.1943-541X.0000735
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Connections with glued-in rods are very efficient, high-strength joints and can be successfully used, for example, for the anchorage of vertical timber elements to a foundation. Although extensive research was done on the pullout strength of single rods, few references can be found on the behavior of multiple glued-in rods. This paper presents the results of an experimental program carried out on timber-to-steel connections with multiple glued-in rods. Two series of 10 specimens with four large-diameter, glued-in rods made from mild steel (Series GB) and 10 specimens with 12 small-diameter, high-grade glued-in rods (Series GS) were tested to failure under monotonic tensile load. Both types of connections ultimately failed in a brittle manner; however, the GB series developed some plastic deformations prior to failure which was caused by the pullout of two rods and longitudinal splitting of the timber member. By comparing the experimental results with the analytical predictions, no significant group effect could be detected in the GB test series, and an overall acceptable approximation was found. In the GS test series, no final conclusion on the group effect could be drawn as several rods failed by nut-stripping. A parametric study using analytical formulas was carried out to investigate the effect of rod strength, rod diameter, glued length, and timber density on the connection performance. Based on the results of the parametric study and experimental tests, it can be concluded that the use of mild steel as well as more rods of larger diameter, properly spaced from each other, and from the edges are all effective measures to increase the connection ductility. Furthermore, by leaving a suitable length of rod unbonded between the steel plate and the glued length, it is possible to control ductility, providing all brittle failure modes have a higher strength capacity than the rod-yielding force. Special care should be taken during the manufacturing process to ensure good quality of gluing (required glued length and amount of adhesive) and rod alignment.
引用
收藏
页码:1468 / 1477
页数:10
相关论文
共 50 条
  • [41] Glued-in rods in cross laminated timber - Numerical simulations and parametric studies
    Azinovic, Boris
    Danielsson, Henrik
    Serrano, Erik
    Kramar, Miha
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 212 : 431 - 441
  • [42] Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Azinovic, Boris
    Serrano, Erik
    Kramar, Miha
    Pazlar, Tomaz
    MATERIALS AND STRUCTURES, 2018, 51 (06)
  • [43] Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Boris Azinović
    Erik Serrano
    Miha Kramar
    Tomaž Pazlar
    Materials and Structures, 2018, 51
  • [44] Behaviour of timber connections using glued-in GFRP rods under fatigue loading. Part II: Moment-resisting connections
    Madhoushi, Mehrab
    Ansell, Martin P.
    COMPOSITES PART B-ENGINEERING, 2008, 39 (02) : 249 - 257
  • [45] Experimental and analytical analysis of moment-resisting connections with glued-in rods
    Ogrizovic, Jelena
    Wanninger, Flavio
    Frangi, Andrea
    ENGINEERING STRUCTURES, 2017, 145 : 322 - 332
  • [46] An analytical procedure for failure and stiffness prediction of glued-in rod timber connections
    Alavi, S. Karen
    Valipour, Hamid R.
    Bradford, Mark A.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2025, 140
  • [47] Experimental test of threaded steel rods glued-in hardwood with epoxy
    Otero, D.
    Estevez, J.
    Martin, E.
    Vazquez, J. A.
    HIGH PERFORMANCE STRUCTURES AND MATERIALS III, 2006, 85 : 63 - +
  • [48] Load-slip behaviour of glue laminated timber connections with glued-in steel rod parallel to grain
    Ling, Zhibin
    Xiang, Zhe
    Liu, Weiqing
    Yang, Huifeng
    Tang, Ju
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 227
  • [49] Correction to: Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Boris Azinović
    Erik Serrano
    Miha Kramar
    Tomaž Pazlar
    Materials and Structures, 2019, 52
  • [50] A component method for moment-resistant glulam beam-column connections with glued-in steel rods
    Yang, Huifeng
    Liu, Weiqing
    Ren, Xiao
    ENGINEERING STRUCTURES, 2016, 115 : 42 - 54