Real-time correction of geometric distortion artefacts in large-volume optical coherence tomography

被引:7
|
作者
Van der Jeught, Sam [1 ]
Buytaert, Jan A. N. [1 ]
Bradu, Adrian [2 ]
Podoleanu, Adrian Gh [2 ]
Dirckx, Joris J. J. [1 ]
机构
[1] Univ Antwerp, Lab Biomed Phys, B-2020 Antwerp, Belgium
[2] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
关键词
optical coherence tomography; real time; GPU; distortion correction;
D O I
10.1088/0957-0233/24/5/057001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Large-volume optical coherence tomography (OCT) setups employ scanning mirrors and suffer from geometric distortion artefacts in which the degree of distortion is determined by the maximum angles over which the mirrors rotate. In this note, we describe a straightforward coordinate transformation scheme to correct for these artefacts in three dimensions, creating an alternative to previously reported ray-tracing schemes. We demonstrate that this recalibration procedure can be applied in real time by implementing the proposed algorithm on the graphics card of a standard computer, making it useful for topography applications. The accuracy of the proposed calibration procedure is validated over an imaging volume of 12.35 x 10.13 x 2.36 mm(3) using optical moire measurements of a highly curved object.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Real-time phase resolved optical coherence tomography and optical Doppler tomography using optical Hilbert Transformation
    Zhao, YH
    Ding, ZH
    Ren, HW
    Miao, JJ
    Jung, WG
    Nelson, JS
    Chen, ZP
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 115 - 119
  • [32] Correction of geometric Distortions for the Calibration of optical Coherence Tomography Systems
    Stritzel, Jenny
    Diaz-Diaz, Jesus
    Rahlves, Maik
    Majdani, Omid
    Ortmaier, Tobias
    Reithmeier, Eduard
    Roth, Bernhard
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 233 - 238
  • [33] A real-time large-volume content delivery system using globally distributed storage
    Media Processing Systems Research Group, Media Innovation Laboratory, NTT Network Innovation Laboratories, Japan
    不详
    不详
    J. Natl. Inst. Inf. Commun. Technol., 2 (101-111):
  • [34] Automatic real-time XRII local distortion correction method for digital linear tomography
    Forlani, C
    Ferrigno, G
    COMPUTATIONAL SCIENCE -- ICCS 200, PROCEEDINGS PT 2, 2001, 2074 : 23 - 26
  • [35] In vivo real-time optical coherence tomography imaging of Drosophila for cardiovascular research
    Jon Holmes
    Nature Methods, 2009, 6 : iii - iv
  • [36] Real-time optical coherence tomography for minimally invasive imaging of prostate ablation
    Boppart, SA
    Herrmann, JM
    Pitris, C
    Stamper, DL
    Brezinski, ME
    Fujimoto, JG
    JOURNAL OF UROLOGY, 2002, 168 (01): : 401 - 401
  • [37] In vivo real-time optical coherence tomography imaging of Drosophila for cardiovascular research
    Holmes, Jon
    NATURE METHODS, 2009, 6 (10) : III - IV
  • [38] Real-time intraoperative spectral domain optical coherence tomography for vitreoretinal surgery
    Tao, Yuankai K.
    Toth, Cynthia A.
    Izatt, Joseph A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [39] Real-Time Subglottic Stenosis Imaging Using Optical Coherence Tomography in the Rabbit
    Lin, Jennifer L.
    Yau, Amy Y.
    Boyd, Jonathon
    Hamamoto, Ashley
    Su, Erica
    Tracey, Lauren
    Heidari, Andrew E.
    Wang, Alex H.
    Ahuja, Gurpreet
    Chen, Zhongping
    Wong, Brian J.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2013, 139 (05) : 502 - 509
  • [40] Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography
    H. Hoerauf
    M. Müller
    G. Hüttmann
    C. Winter
    T. Schlote
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 385 - 390