Objective: The objective of this study was to establish safer cordocentesis by using newly produced 25-gauge needles rather than the needles currently used. Methods: Human umbilical cords were preserved in experiment 1. Pinching both ends, cordocenteses were performed by filling the cord with saline inside the sphere of the pressure-equilibrated Ringer's solution bag in an aquarium. Pressure alterations were recorded before and after the cordocenteses (n = 5 in each needle) using 22-, 23-, and 25-gauge needles. In experiment 2, human umbilical blood after delivery was preserved. Umbilical blood was drawn in syringes, and fixed in syringe infusion pumps of 150 ml/h. The blood (n = 8) was then pushed into the test tubes through 22-, 23-, and 25-gauge needles. Hemolysis and platelet activation were evaluated. As in the case of clinical data, non-stress tests (NST) subsequent to cordocenteses were compared between 23-gauge (n = 19) and 25-gauge (n = 16) needles. Results: In experiment 1, the 25-gauge cordocenteses documented a more favorable pressure curve than other needles. In experiment 2, no statistical significance was observed for plasma-free hemoglobin, total bilirubin, hemoglobin, AST, LDH, potassium, platelet count, beta-thromboglobulin, and platelet factor IV. As in the case of clinical data, NSTs subsequent to cordocenteses revealed strong significance in the duration to recover variability (p = 0.0003) and the duration to recover acceleration (p = 0.0033). Conclusion: We concluded that 25-gauge needles appear superior in avoiding blood loss in the leaking phase. Although blood drawing takes time in the sampling phase, no hemolysis or platelet activation was observed. NST proved that 25-gauge cordocenteses showed favorable patterns. We propose that use of 25-gauge needles is promising under appropriate procedures in cordocentesis. Copyright (C) 2008 S. Karger AG, Basel.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [21] COMPARATIVE-STUDY OF DEFLECTION CHARACTERISTICS AND FRAGILITY OF 25-GAUGE, 27-GAUGE, AND 30-GAUGE SHORT DENTAL NEEDLES
    ROBISON, SF
    MAYHEW, RB
    COWAN, RD
    HAWLEY, RJ
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1984, 109 (06): : 920 - 924
  • [22] 25-gauge vitrectomy: the hidden costs
    L Wickham
    W Aylward
    Eye, 2007, 21 : 1443 - 1443
  • [23] Endophthalmitis following 25-gauge vitrectomy
    S R J Taylor
    G W Aylward
    Eye, 2005, 19 : 1228 - 1229
  • [24] SPATULA KNIFE FOR 25-GAUGE VITRECTOMY
    Ohno, Hisato
    Nagano, Masako
    Inoue, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (02): : 447 - 448
  • [25] 25-gauge transconjunctival sutureless vitrectomy
    Chen, Eric
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (03) : 188 - 193
  • [26] Outcomes following 25-gauge vitrectomies
    Faia, L. J.
    McCannel, C. A.
    Pulido, J. S.
    Hatfield, R. M.
    Hatfield, M. E.
    McNulty, V. E. W.
    EYE, 2008, 22 (08) : 1024 - 1028
  • [27] 25-gauge vitrectomy: The hidden costs
    Wickham, L.
    Aylward, W.
    EYE, 2007, 21 (11) : 1443 - 1443
  • [28] Hypotony After 25-Gauge Vitrectomy
    Bamonte, Giulio
    Mura, Marco
    Tan, H. Stevie
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (01) : 156 - 160
  • [29] Endosonography with 25-gauge core needles for immunohistochemistry and molecular testing in lung cancer patients: a feasibility study
    Misiaszek, Magdalena
    Gnass, Maciej
    Rudnicka, Lucyna
    Soja, Jerzy
    Kuzdzal, Jaroslaw
    Szlubowski, Artur
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2020, 130 (06): : 550 - 552
  • [30] Endophthalmitis following 25-gauge vitrectomy
    Taylor, SRJ
    Aylward, GW
    EYE, 2005, 19 (11) : 1228 - 1229