共 50 条
Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples
被引:20
|作者:
Gonzalez-Hernandez, Providencia
[1
]
Lago, Ana B.
[2
]
Pasan, Jorge
[2
]
Ruiz-Perez, Catalina
[2
]
Ayala, Juan H.
[1
]
Afonso, Ana M.
[1
]
Pino, Veronica
[1
,3
]
机构:
[1] Univ La Laguna, Unidad Dept Quim Analit, Dept Quim, E-38206 Tenerife, Spain
[2] Univ La Laguna, Dept Fis, Lab Rayos X & Mat Mol MATMOL, E-38206 Tenerife, Spain
[3] Univ La Laguna, Univ Inst Trop Dis & Publ Hlth, E-38206 Tenerife, Spain
来源:
关键词:
metal-organic frameworks;
pillared-layer frameworks;
sample preparation;
microextraction;
miniaturized dispersive solid-phase extraction;
personal care products;
POLYCYCLIC AROMATIC-HYDROCARBONS;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
FLUORESCENCE DETECTION;
SORBENT;
MIL-101(CR);
DESIGN;
CONSTRUCTION;
HKUST-1;
ESTERS;
ACID;
D O I:
10.3390/molecules24040690
中图分类号:
Q5 [生物化学];
Q7 [分子生物学];
学科分类号:
071010 ;
081704 ;
摘要:
The pillared-layer Zn-triazolate metal-organic framework (CIM-81) was synthesized, characterized, and used for the first time as a sorbent in a dispersive micro-solid phase extraction method. The method involves the determination of a variety of personal care products in wastewaters, including four preservatives, four UV-filters, and one disinfectant, in combination with ultra-high performance liquid chromatography and UV detection. The CIM-81 MOF, constructed with an interesting mixed-ligand synthetic strategy, demonstrated a better extraction performance than other widely used MOFs in D-mu SPE such as UiO-66, HKUST-1, and MIL-53(Al). The optimization of the method included a screening design followed by a Doehlert design. Optimum conditions required 10 mg of CIM-81 MOF in 10 mL of the aqueous sample at a pH of 5, 1 min of agitation by vortex and 3 min of centrifugation in the extraction step; and 1.2 mL of methanol and 4 min of vortex in the desorption step, followed by filtration, evaporation and reconstitution with 100 mu L of the initial chromatographic mobile phase. The entire D-mu SPE-UHPLC-UV method presented limits of detection down to 0.5 ng mL( -1); intra-day and inter-day precision values for the lowest concentration level (15 ng mL( -1))-as a relative standard deviation (in %)-lower than 8.7 and 13%, respectively; average relative recovery values of 115%; and enrichment factors ranging from 3.6 to 34. The reuse of the CIM-81 material was assessed not only in terms of maintaining the analytical performance but also in terms of its crystalline stability.
引用
收藏
页数:17
相关论文