Design of a monolithic CMOS sensor for high efficiency neutron counting

被引:8
|
作者
Zhang, Ying [1 ]
Hu-Guo, Christine [1 ]
Husson, Daniel [1 ]
Higueret, Stephane [1 ]
The-Duc Le [1 ]
Hu, Yann [1 ]
机构
[1] Univ Strasbourg, CNRS, IPHC, IN2P3, F-67037 Strasbourg, France
关键词
CMOS sensor; Neutron dosimetry; Low-noise readout; Low power consumption; ON-CHIP; DETECTOR;
D O I
10.1016/j.mejo.2012.07.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of CMOS Pixel Sensors (CPS) for charged particles detection had led to promising applications for dosimetry. Based on our previous studies on the detection of fast and thermal neutrons with a CMOS sensor originally designed for particle tracking in high energy physics, a dedicated integrated CMOS sensor for efficient neutron counting is presented. This sensor has been designed and fabricated in a 0.35 pm CMOS process. It is a low noise, low power consumption sensor with a sensitive area of 6.55 mm(2) and a digital output. The test results indicate that it is suitable for neutron detection, thanks to its equivalent input noise charge of less than 400 e(-), and a 20 kHz detection frequency. In this paper the prototype is presented for both its circuit design and test results. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:730 / 736
页数:7
相关论文
共 50 条
  • [41] A dynamically reconfigurable monolithic CMOS pressure sensor for smart fabric
    Sergio, M
    Manaresi, N
    Campi, F
    Canegallo, R
    Tartagni, M
    Guerrieri, R
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (06) : 966 - 975
  • [42] HIGH-EFFICIENCY CERENKOV COUNTING USING A NEW VIAL DESIGN
    ROSS, HH
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1976, 27 (02): : 71 - 78
  • [43] High-Voltage CMOS Active Pixel Sensor Chip With Counting Electronics for Beam Monitoring
    Weber, Alena
    Ehrler, Felix
    Schimassek, Rudolf
    Peric, Ivan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (06) : 1288 - 1298
  • [44] AlphaRad, a new integrated CMOS System-on-Chip for high efficiency alpha particles counting
    Husson, D.
    Bozier, A.
    Higueret, S.
    Le, T. D.
    Nourreddine, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (03): : 845 - 852
  • [45] Multichannel 65 zF rms Resolution CMOS Monolithic Capacitive Sensor for Counting Single Micrometer-Sized Airborne Particles on Chip
    Ciccarella, Pietro
    Carminati, Marco
    Sampietro, Marco
    Ferrari, Giorgio
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2016, 51 (11) : 2545 - 2553
  • [46] The design of an RF monolithic CMOS down-converter
    Chang, KK
    Chiang, YC
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2004, 27 (01) : 161 - 164
  • [47] Study on Optical Efficiency of CMOS Image Sensor to High Performance Imaging Devices
    Cho, Hyo Jong
    Do, Yun Seon
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,
  • [48] Design of a monolithic low voltage high efficiency boost DC-DC converter ASIC based on 0.5um CMOS process
    Deng, H
    Sun, N
    Duan, XM
    Ma, Y
    Huang, AQ
    Chen, D
    ISPSD '04: PROCEEDINGS OF THE 16TH INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES & ICS, 2004, : 169 - 172
  • [49] DESIGN OF HIGH EFFICIENCY LOW BACKGROUND FAST NEUTRON DETECTOR
    BLOOM, SD
    MUEHLHAUSE, CO
    PHYSICAL REVIEW, 1953, 91 (02): : 494 - 495
  • [50] FAST-NEUTRON COUNTING EFFICIENCY OF STILBENE CRYSTAL
    KUDELASEK, Z
    JADERNA ENERGIE, 1977, 23 (05): : 176 - 178