Long-term effects of different cleaning methods on copolyester retainer properties

被引:18
|
作者
Wible, Emily [1 ]
Agarwal, Manika [1 ]
Altun, Sibel [1 ]
Ramir, Tyler [1 ]
Viana, Grace [1 ]
Evans, Carla [2 ]
Lukic, Henry [3 ]
Megremis, Spiro [3 ]
Atsawasuwan, Phimon [1 ]
机构
[1] Univ Illinois, Dept Orthodont, Rm 131,801 S Paulina St, Chicago, IL 60612 USA
[2] Boston Univ, Dept Orthodont & Dentofacial Orthoped, Boston, MA 02215 USA
[3] Amer Dent Assoc, Res & Stand Sci Inst, Chicago, IL USA
关键词
Essix ACE; Thermoplastic retainer; Retainer cleaning; Physical property; Translucency; Flexibility; ORTHODONTIC RETAINERS;
D O I
10.2319/010218-2.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate light transmittance, surface roughness, and flexural modulus of copolyester retainer material after long-term exposure to different cleaning methods. Materials and Methods: Standardized copolyester retainer specimens (ACE) were subjected to seven chemical cleaning solutions for 6 months: Invisalign cleaning crystals, Retainer Brite, Polident, Listerine mouthwash, 2.5% acetic acid, 0.6% NaClO, and 3% H2O2. Seventy specimens (n = 10 per method, 50.8 mm x 12.7 mm x 1.0 mm) were exposed to the different solutions twice a week for 2 minutes or according to manufacturer's instructions and stored in artificial saliva at 37 degrees C. Another group of specimens (n = 10) was brushed with a standardized toothbrushing machine for 2 minutes twice a week. At baseline and 6 months, light transmittance, surface roughness and flexural modulus of the specimens were quantified using spectrophotometry, profilometry, and three-point bend testing, respectively. Qualitative assessment was performed using scanning electron microscopy (SEM). Statistical analyses were accomplished at a significance level of .05. Results: The results indicated that light transmittance through the specimens decreased significantly from baseline for all cleaning methods at 6 months. Flexural modulus of the specimens decreased significantly for all cleaning methods except Invisalign crystals and Retainer Brite (P > .05). The Listerine group demonstrated the worst light transmittance change while H2O2 demonstrated the greatest change in flexural modulus of the specimens compared with other cleaning methods; however, no qualitative difference was observed using SEM analysis. Conclusions: The results suggest that different cleaning methods affect long-term physical properties of the ACE retainer material. At the present time, none of these cleaning methods is ideal for copolyester retainer material.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [31] Long-Term Mechanical Properties of Different Fly Ash Geopolymers
    Gunasekara, Chamila
    Setunge, Sujeeva
    Law, David W.
    ACI STRUCTURAL JOURNAL, 2017, 114 (03) : 743 - 752
  • [32] The Effect of Different Nanomaterials on the Long-term Aging Properties of Bitumen
    Zhang, H. B.
    Zhang, H. L.
    Ke, N. X.
    Huang, J. H.
    Zhu, C. Z.
    PETROLEUM SCIENCE AND TECHNOLOGY, 2015, 33 (04) : 388 - 396
  • [33] LONG-TERM METHODS AND EFFECTS OF REMOTELY TREATING WILDLIFE WITH IMMUNOCONTRACEPTION
    Naugle, Ricky
    Grams, Kayla
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2013, 44 (04) : S138 - S140
  • [34] The Long-Term Sustainability of Different Item Response Theory Scaling Methods
    Keller, Lisa A.
    Keller, Robert R.
    EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 2011, 71 (02) : 362 - 379
  • [35] Different Methods to Induce Visceral Hypersensitivity in Rats: Short- and Long-Term Effects of Inflammation and Stress
    Deiteren, Annemie
    Vermeulen, Wim
    De Man, Joris G.
    Moreels, Tom G.
    Pelckmans, Paul A.
    De Winter, Benedicte Y.
    GASTROENTEROLOGY, 2012, 142 (05) : S894 - S894
  • [36] Comparison of long-term effects of genomic selection index and genomic selection using different Bayesian methods
    Foroutanifar, S.
    LIVESTOCK SCIENCE, 2020, 241
  • [37] Design of a cleaning program for a PV plant based on the analysis of short-term and long-term effects
    Zapata, Jaime W.
    Perez, Marcelo A.
    Kouro, Samir
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 1301 - 1306
  • [38] LONG-TERM EFFECTS
    BERKLEY, C
    AMERICAN JOURNAL OF MEDICAL ELECTRONICS, 1964, 3 (04): : 7 - &
  • [39] Long-term effects?
    Rea, J
    CHEMISTRY & INDUSTRY, 2001, (01) : 8 - 8
  • [40] Cleaning and Caring: Contributions in Long-term Residential Care
    Müller B.
    Armstrong P.
    Lowndes R.
    Ageing International, 2018, 43 (1) : 53 - 73