An anisotropic, hyperelastic model for skin: Experimental measurements, finite element modelling and identification of parameters for human and murine skin

被引:149
|
作者
Groves, Rachel B. [1 ]
Coulman, Sion A. [1 ]
Birchall, James C. [1 ]
Evans, Sam L. [1 ]
机构
[1] Cardiff Univ, Sch Engn, Cardiff CF24 3AA, S Glam, Wales
关键词
Skin; Hyperelastic; Finite element model; IN-VIVO; MECHANICAL-PROPERTIES; CONSTITUTIVE MODEL; BEHAVIOR; TISSUES; IMPLEMENTATION; THICKNESS; TENSION; STRESS; DESIGN;
D O I
10.1016/j.jmbbm.2012.10.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mechanical characteristics of skin are extremely complex and have not been satisfactorily simulated by conventional engineering models. The ability to predict human skin behaviour and to evaluate changes in the mechanical properties of the tissue would inform engineering design and would prove valuable in a diversity of disciplines, for example the pharmaceutical and cosmetic industries, which currently rely upon experiments performed in animal models. The aim of this study was to develop a predictive anisotropic, hyperelastic constitutive model of human skin and to validate this model using laboratory data. As a corollary, the mechanical characteristics of human and murine skin have been compared. A novel experimental design, using tensile tests on circular skin specimens, and an optimisation procedure were adopted for laboratory experiments to identify the material parameters of the tissue. Uniaxial tensile tests were performed along three load axes on excised murine and human skin samples, using a single set of material parameters for each skin sample. A finite element model was developed using the transversely isotropic, hyperelastic constitutive model of Weiss et al. (1996) and was embedded within a Veronda-Westmann isotropic material matrix, using three fibre families to create anisotropic behaviour. The model was able to represent the nonlinear, anisotropic behaviour of the skin well. Additionally, examination of the optimal material coefficients and the experimental data permitted quantification of the mechanical differences between human and murine skin. Differences between the skin types, most notably the extension of the skin at low load, have highlighted some of the limitations of murine skin as a biomechanical model of the human tissue. The development of accurate, predictive computational models of human tissue, such as skin, to reduce, refine or replace animal models and to inform developments in the medical, engineering and cosmetic fields, is a significant challenge but is highly desirable. Concurrent advances in computer technology and our understanding of human physiology must be utilised to produce more accurate and accessible predictive models, such as the finite element model described in this study. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 180
页数:14
相关论文
共 50 条
  • [21] Finite element model to study temperature distribution in skin and deep tissues of human limbs
    Agrawal, Mamta
    Pardasani, K. R.
    JOURNAL OF THERMAL BIOLOGY, 2016, 62 : 98 - 105
  • [22] A THREE LAYER MODEL FOR THE THERMAL IMPEDANCE OF THE HUMAN SKIN: MODELING AND EXPERIMENTAL MEASUREMENTS
    Strakowska, Maria
    De Mey, Gilbert
    Wiecek, Boguslaw
    Strzelecki, Michal
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (04)
  • [23] A novel finite element model of the ovine lumbar intervertebral disc with anisotropic hyperelastic material properties
    Casaroli, Gloria
    Galbusera, Fabio
    Jonas, Rene
    Schlager, Benedikt
    Wilke, Hans-Joachim
    Villa, Tomaso
    PLOS ONE, 2017, 12 (05):
  • [24] Measuring the mechanical properties of human skin in vivo using digital image correlation and finite element modelling
    Evans, S. L.
    Holt, C. A.
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2009, 44 (05): : 337 - 345
  • [25] A FINITE-ELEMENT MODEL FOR THE DESIGN OF LOCAL SKIN FLAPS
    LARRABEE, WF
    GALT, JA
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1986, 19 (04) : 807 - 824
  • [26] A FINITE-ELEMENT MODEL OF SKIN SUBJECTED TO A FLASH FIRE
    TORVI, DA
    DALE, JD
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03): : 250 - 255
  • [27] Determination of the temperature distribution in skin using a finite element model
    Andersen, TN
    Jessen, NC
    Arendt-Nielsen, L
    LASER-TISSUE INTERACTION XI: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2000, 3914 : 54 - 65
  • [28] Non-linear spacecraft component parameters identification based on experimental results and finite element modelling
    Vismara, S. O.
    Ricci, S.
    Bellini, M.
    Trittoni, L.
    CEAS SPACE JOURNAL, 2016, 8 (02) : 89 - 100
  • [29] Identification of susceptibility loci for skin disease in a murine psoriasis model
    Kess, Daniel
    Lindqvist, Anna-Karin B.
    Peters, Thorsten
    Wang, Honglin
    Zamek, Jan
    Nischt, Roswitha
    Broman, Karl W.
    Blakytny, Robert
    Krieg, Thomas
    Holmdahl, Rikard
    Scharffetter-Kochanek, Karin
    JOURNAL OF IMMUNOLOGY, 2006, 177 (07): : 4612 - 4619
  • [30] Mechanics of dissolving microneedles insertion into the skin: Finite element and experimental analyses
    Babapour, Fatemeh
    Faraji Rad, Zahra
    Ganji, Fariba
    Journal of Applied Polymer Science, 1600, 141 (38):