Fatal Delayed Coronary Artery Perforation After Coronary Stent Implantation

被引:0
|
作者
Kim, Sang-Hoon [1 ]
Moon, Jae-Youn [1 ]
Sung, Jung-Hoon [1 ]
Kim, In Jai [1 ]
Lim, Sang-Wook [1 ]
Cha, Dong-Hun [1 ]
Cho, Seung-Yun [1 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Cardiol, Songnam 463712, South Korea
关键词
Cardiac tamponade; Complications; Percutaneous transluminal coronary angioplasty; Drug-eluting stent;
D O I
10.4070/kcj.2012.42.5.352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Most type I and II perforations are predominately caused by hydrophilic and stiff wires, often presented in the delayed form, and do not require pericardial drainage or surgical interventions. However, we report a type III delayed coronary artery perforation at the site of stent implantation after intervention without any evidence of immediate perforations. To the best of our knowledge, this is the first case report of angiographic documentation and treatment of delayed coronary perforation at the site of stent, presented as a cardiac arrest.
引用
收藏
页码:352 / 354
页数:3
相关论文
共 50 条
  • [31] Coronary Artery Disease Progression Late After Successful Stent Implantation
    Zellweger, Michael J.
    Kaiser, Christoph
    Jeger, Raban
    Brunner-La Rocca, Hans-Peter
    Buser, Peter
    Bader, Franziska
    Mueller-Brand, Jan
    Pfisterer, Matthias
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (09) : 793 - 799
  • [32] Type A dissection after right coronary artery stent-implantation
    Meltem Hacibayramoglu
    Ernst Girth
    Hans-Rüdiger Mahlo
    Harald Klepzig
    Clinical Research in Cardiology, 2009, 98 : 140 - 140
  • [33] Coronary artery perforation after bioresorbable scaffold implantation treated with a new generation covered stent-OCT insights
    Chen, D.
    Gadeley, R.
    Wang, A.
    Jepson, N.
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [34] Delayed Endothelialization After Polytetrafluoroethylene-Covered Stent Implantation for Coronary Aneurysm
    Takano, Masamichi
    Yamamoto, Masanori
    Inami, Shigenobu
    Xie, Yong
    Murakami, Daisuke
    Okamatsu, Kentaro
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    CIRCULATION JOURNAL, 2009, 73 (01) : 190 - 193
  • [35] Managing coronary artery perforation after percutaneous coronary intervention
    Kassier, Adnan
    Fischell, Tim A.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2022, 20 (03) : 215 - 222
  • [36] Coronary artery perforation and delayed cardiac tamponade following balloon coronary angioplasty
    Tseng, CD
    Chen, GY
    Chiang, FT
    Hsu, KL
    Lo, HM
    Tseng, YZ
    Tsai, CH
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1996, 95 (10) : 789 - 792
  • [37] Multiple coronary artery perforation as a fatal complication during the management of an undeflatable stent balloon: a case report
    Kim, Seok Hyun
    Lee, Sang Hyun
    Kim, Jeongsu
    Chun, Kook Jin
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2025, 12
  • [38] Fatal Ostial Right Coronary Artery Coronary Stent Fracture and Perforation Induced by Mechanical Stress Between the Sternum and Dilated Aortic Root
    Hoshi, Tomoya
    Sato, Akira
    Nishina, Hidetaka
    Kakefuda, Yuki
    Noguchi, Yuichi
    Aonuma, Kazutaka
    CIRCULATION, 2011, 123 (15) : 1679 - 1682
  • [39] Stent graft implantation for in-stent restenosis of coronary artery stenosis after Kawasaki disease
    Yoon, Min Jeong
    Lee, Jae Young
    Kim, Soo-Jin
    Jang, Ki Young
    Shim, Woo Sup
    Hwang, Hweung Kon
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 113 (02) : 264 - 266
  • [40] Risk factors for in-stent restenosis after coronary stent implantation in patients with coronary artery disease: A retrospective observational study
    Zhang, Juan
    Zhang, Qian
    Zhao, Ke
    Bian, Yu-Jing
    Liu, Yang
    Xue, Yi-Tao
    MEDICINE, 2022, 101 (47) : E31707