Impact of thyroid gland shielding on radiation doses in dental cone beam computed tomography with small and medium fields of view

被引:10
|
作者
Gruening, Melanie [1 ]
Koivisto, Juha [2 ]
Mah, James [3 ]
Bumann, Axel [4 ,5 ]
机构
[1] Charite Univ Med Berlin, Berlin, Germany
[2] Univ Helsinki, Helsinki, Finland
[3] Univ Nevada, Las Vegas, NV 89154 USA
[4] Private Orthodont Clin, Berlin, Germany
[5] MESANTIS 3DDENT RADIOL, Berlin, Germany
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2022年 / 134卷 / 02期
关键词
AMERICAN ACADEMY; IMAGE QUALITY; CT; REDUCTION; STATEMENT; DOSIMETRY; EXPOSURE; CANCER;
D O I
10.1016/j.oooo.2022.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to evaluate the impact of thyroid gland shielding on radiation doses in dental cone beam computed tomography (CBCT) with small and medium fields of view (FOVs). Study Design. Six CBCT protocols were investigated by exposing an adult anthropomorphic male phantom head without and with thyroid shielding, using 4 small (4 x 5 cm) and 2 medium (10 x 6 cm) FOVs. Twenty metal oxide semiconductor field-effect transistor dosimeters were placed in the phantom head to measure absorbed doses and calculate equivalent doses at 11 sites. Effective doses were calculated based on the tissue weighting factors in International Commission on Radiological Protection Publication 103. The data were analyzed using the independent samples t test. Results. Thyroid gland shielding led to significant equivalent dose reductions in many tissues for all protocols. Equivalent dose reductions to the thyroid were significant in all 6 protocols (P <=.037). Significant reduction depended on the FOV and ranged between 24.5% and 42.6% for the thyroid gland and 4.9% and 34.5% for other tissues and organs. Effective doses were significantly lower in all protocols (P <=.016). Conclusions. Thyroid gland shielding protects the thyroid gland and other organs and should be utilized with all CBCT examinations where feasible.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [31] Quantitative performance characterization of image quality and radiation dose for a CS 9300 dental cone beam computed tomography machine
    Abouei, Elham
    Lee, Sierra
    Ford, Nancy L.
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [32] Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment
    Song, Chang-Ho
    Yeom, Han-Gyeol
    Kim, Jo-Eun
    Huh, Kyung-Hoe
    Yi, Won-Jin
    Heo, Min-Suk
    Lee, Sam-Sun
    IMAGING SCIENCE IN DENTISTRY, 2022, : 283 - 288
  • [33] The effect of varying cone beam computed tomography image resolution and field-of-view centralization on effective radiation dose
    Jadu, Fatima M.
    Alzahrani, Asmaa A.
    Almutairi, Maha A.
    Al-Amoudi, Salma O.
    Jan, Ahmed M.
    Khafaji, Mawya A.
    SAUDI MEDICAL JOURNAL, 2018, 39 (05) : 470 - 475
  • [34] Thyroid shields for radiation dose reduction during cone beam computed tomography scanning for different oral and maxillofacial regions
    Qu, Xingmin
    Li, Gang
    Zhang, Zuyan
    Ma, Xuchen
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E376 - E380
  • [35] Distribution of metal artifacts arising from the exomass in small field-of-view cone beam computed tomography scans
    Candemil, Amanda P.
    Salmon, Benjamin
    Freitas, Deborah Queiroz
    Haiter-Neto, Francisco
    Oliveira, Matheus Lima
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2020, 130 (01): : 116 - 125
  • [36] Effective doses of dental cone beam computed tomography: effect of 360-degree versus 180-degree rotation angles
    Mutalik, Sunil
    Tadinada, Aditya
    Molina, Marco R.
    Sinisterra, Andres
    Lurie, Alan
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2020, 130 (04): : 433 - 446
  • [37] The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography
    Moudi, Ehsan
    Haghanifar, Sina
    Madani, Zahrasadat
    Bijani, Ali
    Nabavi, Zeynab Sadat
    IMAGING SCIENCE IN DENTISTRY, 2015, 45 (03) : 147 - 151
  • [38] Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices
    Cascante-Sequeira, Deivi
    Coelho-Silva, Fernanda
    Rosado, Lucas P. Lopes
    Freitas, Deborah Queiroz
    de-Azevedo-Vaz, Sergio Lins
    Haiter-Neto, Francisco
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (01) : 1025 - 1033
  • [39] Assessing Genotoxicity and Cytotoxicity Induced by X-Ray Exposure From Cone Beam Computed Tomography at Varied Fields of View
    Vishwadha, Chintha
    Thanmai, Janumpally Varshitha
    Ramlal, G.
    Goud, Srikanth
    Katne, Tejaswi
    Reddy, Poreddy Vaishnavi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [40] Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices
    Deivi Cascante-Sequeira
    Fernanda Coelho-Silva
    Lucas P. Lopes Rosado
    Deborah Queiroz Freitas
    Sergio Lins de-Azevedo-Vaz
    Francisco Haiter-Neto
    Clinical Oral Investigations, 2022, 26 : 1025 - 1033