Pulse Oximetry in the Diagnosis of Acute Heart Failure

被引:5
|
作者
Masip, Josep [1 ]
Gaya, Maria [1 ]
Paez, Joaquim [1 ]
Betbese, Antoni [1 ]
Vecilla, Francisco [1 ]
Manresa, Ruben [1 ]
Ruiz, Pilar [1 ]
机构
[1] Univ Barcelona, Unidad Cuidados Intens, Hosp St Joan Despi Moises Broggi, Consorci Sanitari Integral, Barcelona 08970, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2012年 / 65卷 / 10期
关键词
Pulse oximetry; Oxygen saturation; Acute heart failure; Myocardial infarction; ACUTE MYOCARDIAL-INFARCTION; NATRIURETIC PEPTIDE; OXYGEN-THERAPY; SLEEP-APNEA; HYPOXEMIA; GUIDELINES; PATIENT;
D O I
10.1016/j.rec.2012.02.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Oxygen saturation by pulse oximetry is commonly used for monitoring critical patients, but its utility as a diagnostic marker of acute heart failure has not been assessed. This study analyzed the diagnostic role of oxygen saturation by pulse oximetry in a series of patients with acute myocardial infarction. Methods: In a prospective observational cohort study of 220 consecutive patients with acute myocardial infarction, data collection included baseline oxygen saturation by pulse oximetry (without oxygen), physiologic measurements, Killip class and data from portable chest radiography, recorded at the same hour on each of the first three days after admission. Patients were followed up for one year. Results: There were 612 assessments. Baseline oxygen saturation by pulse oximetry decreased progressively in relation to the presence and the severity of acute heart failure assessed by Killip classes 1 to 3 (mean: 95, 92 and 85, respectively; P<.001) or by radiology score 0 to 4 (95, 94, 92, 89 and 83, respectively; P<.001), with a correlation coefficient of 0.66 and 0.63, respectively. Receiver operating characteristic curves disclosed the cut-off of oxygen saturation by pulse oximetry <93 to have the greatest area, with a sensitivity of 65%, specificity 90%, and overall test accuracy 83%. Patients grouped according to lowest oxygen saturation by pulse oximetry showed significantly different rates of one-year mortality or rehospitalization for heart failure. Conclusions: Baseline oxygen saturation by pulse oximetry is useful in establishing the diagnosis and severity of heart failure in acute settings such as myocardial infarction and may have prognostic implications. The diagnosis may be suspected when baseline oxygen saturation by pulse oximetry is <93. (C) 2012 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:879 / 884
页数:6
相关论文
共 50 条
  • [21] Effect of fetal echocardiography and pulse oximetry screening on age at diagnosis of congenital heart disease
    Diejomaoh, E
    Druschel, CM
    Carter, T
    Romano, A
    Shapir, Y
    Gandhi, M
    Bierman, FZ
    Koppel, R
    PEDIATRIC RESEARCH, 2004, 55 (04) : 524A - 524A
  • [22] Brachial pulse pressure in acute heart failure. Results of the Heart Failure Registry
    Bonapace, Stefano
    Rossi, Andrea
    Laroche, Cecile
    Crespo-Leiro, Maria G.
    Piepoli, Massimo F.
    Coats, Andrew J. S.
    Dahlstrom, Ulf
    Malek, Filip
    Macarie, Cezar
    Temporelli, Pier Luigi
    Maggioni, Aldo P.
    Tavazzi, Luigi
    ESC HEART FAILURE, 2019, 6 (06): : 1167 - 1177
  • [23] Pulse oximetry screening of congenital heart disease
    Serrano Madrid, M. L.
    Cardiel Valiente, L.
    Romero Gil, R.
    Pena Busto, A.
    BOLETIN DE PEDIATRIA, 2020, 60 (254): : 158 - 163
  • [24] Pulse oximetry for the diagnosis of vascular limb trauma
    Kwasnicki, Richard Mark
    Burgin, Joseph
    Paton, Christopher
    Hettiaratchy, Shehan
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (09): : 3182 - 3189
  • [25] Pulse oximetry screening for congenital heart defects
    Ewer, Andrew K.
    Granelli, Anne De-Wahl
    Manzoni, Paolo
    Sanchez Luna, Manuel
    Martin, Gerard R.
    LANCET, 2013, 382 (9895): : 856 - 857
  • [26] Screening with pulse oximetry for congenital heart disease
    Mahle, William
    Koppel, Robert
    LANCET, 2011, 378 (9793): : 749 - 750
  • [27] A Pitfall in Measuring Heart Rates With Pulse Oximetry
    Chuman, Takuya
    Iio, Kazuki
    Yanai, Shun
    Hagiwara, Yusuke
    Maeda, Jun
    ANNALS OF EMERGENCY MEDICINE, 2023, 82 (04) : 472 - 474
  • [28] Biomarkers for Diagnosis and Prognosis of Acute Heart Failure
    Choudhary, Rajiv
    Di Somma, Salvatore
    Maisel, Alan S.
    CURRENT EMERGENCY AND HOSPITAL MEDICINE REPORTS, 2013, 1 (02): : 133 - 140
  • [29] Acute heart failure: differential diagnosis and treatment
    Marini, Marco
    Manfredi, Roberto
    Battistoni, Ilaria
    Francioni, Matteo
    Matassini, Maria Vittoria
    Pongetti, Giulia
    Angelini, Luca
    Shkoza, Matilda
    Bontempo, Alessandro
    Belfioretti, Leonardo
    Perna, Gian Piero
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : C276 - C282
  • [30] Refining the diagnosis of acute heart failure in the elderly
    Riccardi, Mauro
    Pagnesi, Matteo
    ESC HEART FAILURE, 2024, 11 (06): : 3463 - 3465