摘要
The performance efficiency of natural smoke ventilation in atria spaces are influenced greatly by several design decisions such as atrium shape, height, size and openings location. This paper investigates the impact of atrium shape (horizontal profile) on smoke ventilation performance in naturally ventilated atria. Three different configurations (square, rectangular and triangular prism) with the same area, height, and hence, volume were tested. The smoke ventilation performance is being assessed in terms of smoke filling time using a computational fire dynamic simulator (FDS). FDS is used to simulate the natural smoke filling resulting from atrium fire in the three configurations. The smoke layer interface height as a function of time and soot mass fraction and temperature as a function of height have been registered during the simulation. The predicted transport lag time for initial formation of the smoke layer beneath the ceiling (ceiling jet) was compared for the three tests. In order to test sensitivity of the shapes, all other parameters were designed to be similar in the three tests, and the same fire scenario was applied including inlet and outlet area, and fire size and location. The results showed that the rectangular configuration contributes better to smoke ventilation, and that the triangular configuration is the most critical in terms of smoke filling time, followed by the square configuration. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [1] Fundamental atrium design for natural ventilation
    Holford, JM
    Hunt, GR
    BUILDING AND ENVIRONMENT, 2003, 38 (03) : 409 - 426
  • [2] Atrium Smoke Management Natural Venting Challenges
    Sinclair, Ray
    Du, Xiangdong
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 106 - 118
  • [3] Natural smoke filling in PolyU/USTC Atrium
    Chow, W.K.
    Cui, E.
    Huo, R.
    Journal of Architectural Engineering, 2000, 6 (03) : 99 - 101
  • [4] The Analysis of the Natural Smoke Filling Times in an Atrium
    Wu, Guan-Yuan
    Chen, Ruu-Chang
    JOURNAL OF COMBUSTION, 2010, 2010
  • [5] Scale modeling on natural smoke filling in an atrium
    Chow, W. K.
    Lo, Henry H. W.
    HEAT TRANSFER ENGINEERING, 2008, 29 (01) : 76 - 84
  • [6] The Impact of Outdoor Temperatures on the Efficacy of Natural Ventilation and Smoke Exhaust Systems
    Boguslawska, Arleta
    Brzezinska, Dorota
    ENERGIES, 2022, 15 (03)
  • [7] Simulation on natural smoke filling in atrium with a balcony spill plume
    Chow, WK
    Li, J
    JOURNAL OF FIRE SCIENCES, 2001, 19 (04) : 258 - 283
  • [8] Effects of outdoor temperature on the natural smoke extraction strategy in an atrium
    Zhen Lanlan
    Ran Feng
    PROCEEDINGS OF THE 2015 INTERNATIONAL INDUSTRIAL INFORMATICS AND COMPUTER ENGINEERING CONFERENCE, 2015, : 2051 - 2058
  • [9] Natural ventilation of residential building Atrium under fire scenario
    Al-Waked, Rafat
    Nasif, Mohammad
    Groenhout, Nathan
    Partridge, Lester
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [10] CFD modelling of natural displacement ventilation in an enclosure connected to an atrium
    Ji, Y.
    Cook, M. J.
    Hanby, V.
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1158 - 1172