Experimental Study on the Stability of the Mercuric Complexes in Wet Flue Gas Desulfurization Wastewater

被引:0
|
作者
Huang, Yu [1 ]
Han, Peng-Shuai [1 ]
Guo, Xin [1 ]
Zheng, Chu-Guang [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Coal Combust, Wuhan 430074, Peoples R China
关键词
Mercuric complexes; Stabilization estimate; WFGD wastewater; UTILITY BOILERS; POWER-PLANTS; FGD SYSTEMS; EMISSIONS; REEMISSION; STABILIZATION; REDUCTION; OXIDATION; ADDITIVES; SCRUBBER;
D O I
10.1007/978-981-10-2023-0_63
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper discussed the stability of ClHgSO3- complexes in desulfurization wastewater after it emitted from WFGD system. The results of experiments showed that the increase in temperature promotes ClHgSO3- complex decomposition which fitted the pseudo first-order kinetics principle, and the Ea value was calculated to 19.93 J/mol. The increase of H+ concentration in the solution stimulates the decomposition of ClHgSO3- complexes. The result of competitive reaction indicated that Ca2+ was easier to react with SO32- than Hg2+ to form CaSO3, which is slightly soluble and stimulated the decomposition of complexes. SO42- ions inhibit the forward reaction of ClHgSO3- decomposition and promote ORP value of wastewater, which avoid the formation of unstable HgSO3. It was also found that Hg2+ concentration was relatively low in wastewater, and decomposition reaction cannot be evaluated by ORP change. Moreover, ORP value and variation negligibly reflect the stability of complexes.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [21] STUDY ON PROPERTIES OF CARBIDE SLAG IN WET FLUE GAS DESULFURIZATION
    Cheng, Ming-Tao
    Feng, Xiao-Ming
    ENERGY, ENVIRONMENTAL & SUSTAINABLE ECOSYSTEM DEVELOPMENT, 2016,
  • [22] Study on the automatic control method for evaporation treatment of wet flue gas desulfurization wastewater in power plants
    Guo, Xiangjian
    Zhang, Bo
    Li, Yanmeng
    Feng, Yue
    Xu, Shuowen
    WATER SCIENCE AND TECHNOLOGY, 2024, 90 (05) : 1545 - 1560
  • [23] Wet flue gas desulfurization wastewater treatment with reclaimed water treatment plant sludge: a case study
    Chen, Hong
    Wang, Yiyu
    Wei, Yanxiao
    Peng, Liang
    Jiang, Bo
    Li, Gang
    Yu, Guanlong
    Du, Chunyan
    WATER SCIENCE AND TECHNOLOGY, 2018, 78 (11) : 2392 - 2403
  • [24] Corrosion in Wet Flue Gas Desulfurization Absorbers
    Tossey, Brett
    POWER ENGINEERING, 2011, 115 (01) : 20 - +
  • [25] Experimental Study on Removal Characteristics of SO3 by Wet Flue Gas Desulfurization Absorber
    Zheng, Chenghang
    Hong, Yipan
    Xu, Zhewei
    Li, Cunjie
    Wang, Li
    Yang, Zhengda
    Zhang, Yongxin
    Gao, Xiang
    ENERGY & FUELS, 2018, 32 (05) : 6031 - 6038
  • [26] Research on wet flue gas desulfurization by waste
    Zhejiang Univ, Hangzhou, China
    Ranshao Kexue Yu Jishu/Journal of Combustion Science and Technology, 1998, 4 (04): : 396 - 402
  • [27] Reactivity of the limestone in wet flue gas desulfurization
    2005, Science Press, Beijing, China (26):
  • [28] Variations in heavy metals and turbidity in wastewater from wet flue gas desulfurization by electrocoagulation
    Zhou, C.
    Zhang, H. Y.
    Chen, J. W.
    Liu, X. L.
    Wang, R.
    Tan, W. Y.
    DESALINATION AND WATER TREATMENT, 2019, 141 : 82 - 88
  • [29] Influence of wet flue gas desulfurization on the pollutants monitoring in FCC flue gas
    Ju, Feng
    Wu, Cong
    Luan, Hui
    Tang, Zhihe
    Pan, Helin
    Pan, Hui
    Xiu, Guangli
    Ling, Hao
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (39) : 55502 - 55510
  • [30] Influence of wet flue gas desulfurization on the pollutants monitoring in FCC flue gas
    Feng Ju
    Cong Wu
    Hui Luan
    Zhihe Tang
    Helin Pan
    Hui Pan
    Guangli Xiu
    Hao Ling
    Environmental Science and Pollution Research, 2021, 28 : 55502 - 55510