Nonlinear damping based semi-active building isolation system

被引:21
|
作者
Ho, Carmen [1 ]
Zhu, Yunpeng [1 ]
Lang, Zi-Qiang [1 ]
Billings, Stephen A. [1 ]
Kohiyama, Masayuki [2 ]
Wakayama, Shizuka [2 ]
机构
[1] Univ Sheffield, Dept Automat Control & Syst Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Keio Univ, Dept Syst Design Engn, Hiyoshi, Japan
基金
英国工程与自然科学研究理事会; 欧洲研究理事会;
关键词
Isolation system; Earthquake; Nonlinear damping; Acceleration transmissibilities; Experimental studies; FREQUENCY-RESPONSE FUNCTION; VIBRATION CONTROL; DESIGN; STIFFNESS; DRIFT;
D O I
10.1016/j.jsv.2018.03.023
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Many buildings in Japan currently have a base-isolation system with a low stiffness that is designed to shift the natural frequency of the building below the frequencies of the ground motion due to earthquakes. However, the ground motion observed during the 2011 Tohoku earthquake contained strong long-period waves that lasted for a record length of 3 min. To provide a novel and better solution against the long-period waves while maintaining the performance of the standard isolation range, the exploitation of the characteristics of nonlinear damping is proposed in this paper. This is motivated by previous studies of the authors, which have demonstrated that nonlinear damping can achieve desired performance over both low and high frequency regions and the optimal nonlinear damping force can be realized by closed loop controlled semi-active dampers. Simulation results have shown strong vibration isolation performance on a building model with identified parameters and have indicated that nonlinear damping can achieve low acceleration trans-missibilities round the structural natural frequency as well as the higher ground motion frequencies that have been frequently observed during most earthquakes in Japan. In addition, physical building model based laboratory experiments are also conducted, The results demonstrate the advantages of the proposed nonlinear damping technologies over both traditional linear damping and more advanced Linear-Quadratic Gaussian (LQG) feedback control which have been used in practice to address building isolation system design and implementation problems. In comparison with the tuned-mass damper and other active control methods, the proposed solution offers a more pragmatic, low-cost, robust and effective alternative that can be readily installed into the base-isolation system of most buildings. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:302 / 317
页数:16
相关论文
共 50 条
  • [31] A comparison of semi-active damping control strategies for vibration isolation of harmonic disturbances
    Liu, Y
    Waters, TP
    Brennan, MJ
    JOURNAL OF SOUND AND VIBRATION, 2005, 280 (1-2) : 21 - 39
  • [32] Simultaneous Multi-objective Optimization of Semi-active Intermediate Isolation System and Building Structure
    Hyun-Su Kim
    Joo-Won Kang
    International Journal of Steel Structures, 2021, 21 : 604 - 612
  • [33] An intelligent semi-active isolation system based on ground motion characteristic prediction
    Lin, Tzu-Kang
    Lu, Lyan-Ywan
    Hsiao, Chia-En
    Lee, Dong-You
    EARTHQUAKES AND STRUCTURES, 2022, 22 (01) : 53 - 64
  • [34] NONLINEAR CONTROL OF SEMI-ACTIVE MACPHERSON SUSPENSION SYSTEM
    Anubi, Olugbenga M.
    Crane, Carl D., III
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 6, 2012, : 397 - 406
  • [35] Active/semi-active hybrid isolation system with fuzzy switching controller
    Fu, Jie
    Li, Peidong
    Liao, Guanyao
    Lai, Junjie
    Yu, Miao
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (01) : 101 - 115
  • [36] Digital control for semi-active isolation system with magnetorheological damper
    Pan, Cunzhi
    Yang, Shaopu
    ICICIC 2006: FIRST INTERNATIONAL CONFERENCE ON INNOVATIVE COMPUTING, INFORMATION AND CONTROL, VOL 1, PROCEEDINGS, 2006, : 682 - +
  • [37] Periodic motions and stability in a semi-active suspension system with MR damping
    Luo, Albert C. J.
    Rajendran, Arun
    JOURNAL OF VIBRATION AND CONTROL, 2007, 13 (05) : 687 - 709
  • [38] Forced vibration test of a building with semi-active damper system
    Kurata, Narito
    Kobori, Takuji
    Takahashi, Motoichi
    Ishibashi, Toshihisa
    Niwa, Naoki
    Tagami, Jun
    Midorikawa, Hiroshi
    Earthquake Engineering and Structural Dynamics, 2000, 29 (05) : 629 - 645
  • [39] Blast shock isolation system with MRFD and the semi-active control
    Department of Civil Engineering, Tsinghua University, Beijing 100084, China
    Gongcheng Lixue, 2008, 1 (167-172):
  • [40] Forced vibration test of a building with semi-active damper system
    Kurata, N
    Kobori, T
    Takahashi, M
    Ishibashi, T
    Niwa, N
    Tagami, J
    Midorikawa, H
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (05): : 629 - 645