Application of Single Voxel 1H Magnetic Resonance Spectroscopy in Hepatic Benign and Malignant Lesions

被引:3
|
作者
Yang, Zifeng [1 ]
Sun, Shiqiang [2 ]
Chen, Yuanli [3 ]
Li, Rui [4 ]
机构
[1] Licheng Dist Peoples Hosp, Dept Med Imaging, Jinan, Shandong, Peoples R China
[2] Linyi Luozhuang Cent Hosp, Dept Med Imaging, Linyi, Shandong, Peoples R China
[3] Linyi Luozhuang Cent Hosp, Dept Radiol, Linyi, Shandong, Peoples R China
[4] Jining 1 Peoples Hosp, Dept Radiol, Jining, Shandong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2016年 / 22卷
关键词
Liver Diseases; Liver Neoplasms; Magnetic Resonance Spectroscopy; PROTON MR SPECTROSCOPY; TRANSCATHETER ARTERIAL CHEMOEMBOLIZATION; IN-VIVO DETECTION; HEPATOCELLULAR-CARCINOMA; BRAIN-TUMORS; BREAST-LESIONS; LIVER-DISEASE; METABOLISM; FIBROSIS; GLYCINE;
D O I
10.12659/MSM.902177
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: To quantify the metabolite changes in hepatic tumors by single-voxel H-1 magnetic resonance spectroscopy (MRS) at 3.0 T and explore the application value of (HMRS)-H-1 in the diagnosis of hepatic benign and malignant lesions. Material/Methods: A total of 45 patients (55 lesions) diagnosed with hepatic lesions by ultrasound and/or computer topography (CT) from November 2006 to March 2007 were included in this study. All patients underwent 3D-dynamic enhanced scan with liver acquisition with acceleration volume acquisition (LAVA) sequence and single-voxel 1HMRS imaging with PRESS (point-resolved spectroscopy) sequence. The metabolite concentrations such as choline (Cho) and lipids (Lip) were measured. Results: There was significant difference regarding the occurrence rate of the obvious elevated Cho peaks between benign and malignant tumors (7/27 vs. 21/28, p=0.000). There was statistical significant differences regarding the Cho/Lip ratios in hepatic benign (0.0686 +/- 0.0283, 95% CI: 0.0134-0.1245) and malignant (0.1266 +/- 0.1124, 95% CI: 0.0937-0.2203) lesions (p<0.05). When compared with the pathological results, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy were 85.7% (24/28), 92.6% (25/27), 92.3% (24/26), 86.2% (25/29), and 89.1% (49/55) respectively for the MRI assessment, and 92.6% (26/28), 88.9% (24/27), 89.7 (26/29), 92.3 (24/26), and 90.9% (50/55) respectively for 1HMRS combined with MRI assessment. Conclusions: Single Cho peaks or Lip peaks cannot be used for the diagnosis of hepatic benign and malignant lesions. Combined use of 1HMRS and MRI can greatly improve the application value of MRI assessment in the diagnosis of hepatic benign and malignant lesions with a higher sensitivity, negative predictive value, and overall accuracy.
引用
收藏
页码:5003 / 5010
页数:8
相关论文
共 50 条
  • [41] In vivo studies of brain metabolism in animal models of Hepatic Encephalopathy using 1H Magnetic Resonance Spectroscopy
    Cudalbu, Cristina
    METABOLIC BRAIN DISEASE, 2013, 28 (02) : 167 - 174
  • [42] Motion correction and lipid suppression for 1H magnetic resonance spectroscopy
    Star-Lack, JM
    Adalsteinsson, E
    Gold, GE
    Ikeda, DM
    Spielman, DM
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (03) : 325 - 330
  • [43] Significance of single and multi-voxel 1H magnetic resonance spectroscopy in the quantification of myocellular lipid in young non-obese Asian Indian males
    Livingstone, Roshan Samuel
    Thomas, Abel Juhan
    Dasgupta, Riddhi
    Anoop, Shajith
    Kurian, Mathews Edatharayil
    Hawkins, Meredith
    Thomas, Nihal
    MAGNETIC RESONANCE IMAGING, 2021, 75 : 65 - 71
  • [44] 1H magnetic resonance spectroscopy study human meningiomas in vitro
    Dobrota, D
    Liptaj, T
    Galanda, M
    Pronayova, N
    Kasparova, S
    Zalibera, L
    Mlynarik, V
    CHEMICAL PAPERS, 1998, 52 : 392 - 392
  • [45] 1H nuclear magnetic resonance spectroscopy-based metabonomic study in patients with cirrhosis and hepatic encephalopathy
    Konstantinos John Dabos
    John Andrew Parkinson
    Ian Howard Sadler
    John Nicholas Plevris
    Peter Clive Hayes
    World Journal of Hepatology, 2015, 7 (12) : 1701 - 1707
  • [46] Diagnosing dural metastases:: the value of 1H magnetic resonance spectroscopy
    Bendszus, M
    Warmuth-Metz, M
    Burger, R
    Klein, R
    Tonn, JC
    Solymosi, L
    NEURORADIOLOGY, 2001, 43 (04) : 285 - 289
  • [47] 1H magnetic resonance spectroscopy for investigation of hippocampal radiation injury
    Pospisil, P.
    Kazda, T.
    Nahodilova, J.
    Bulik, M.
    Slampa, P.
    Jancalek, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S731 - S731
  • [48] Assessment of in vivo 1H magnetic resonance spectroscopy in the liver:: A review
    Fischbach, Frank
    Bruhn, Harald
    LIVER INTERNATIONAL, 2008, 28 (03) : 297 - 307
  • [49] Observation of intramyocellular lipids by means of 1H magnetic resonance spectroscopy
    Boesch, C
    Décombaz, J
    Slotboom, J
    Kreis, R
    PROCEEDINGS OF THE NUTRITION SOCIETY, 1999, 58 (04) : 841 - 850
  • [50] In vivo 1H magnetic resonance spectroscopy study in Cockayne syndrome
    Gabis, L
    Belman, A
    Roche, P
    Huang, W
    ANNALS OF NEUROLOGY, 2000, 48 (03) : 489 - 489