Differences in the dose-volume metrics with heterogeneity correction status and its influence on local control in stereotactic body radiation therapy for lung cancer

被引:9
|
作者
Ueki, Nami [1 ]
Matsuo, Yukinori [1 ]
Shibuya, Keiko [2 ]
Nakamura, Mitsuhiro [1 ]
Narabayashi, Masaru [1 ]
Sakanaka, Katsuyuki [1 ]
Norihisa, Yoshiki [1 ]
Mizowaki, Takashi [1 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Sakyo Ku, Kyoto 6068507, Japan
[2] Yamaguchi Univ, Grad Sch Med, Dept Therapeut Radiol, Ube, Yamaguchi 7558505, Japan
基金
日本学术振兴会;
关键词
lung cancer; stereotactic body radiation therapy; dose-volume metrics; heterogeneity correction; local control; PHASE-II TRIAL; INHOMOGENEITY CORRECTIONS; RADIOTHERAPY; ALGORITHM;
D O I
10.1093/jrr/rrs084
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study is to evaluate the dose-volume metrics under different heterogeneity corrections and the factors associated with local recurrence (LR) after stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). Eighty-three patients who underwent SBRT for pathologically proven stage I NSCLC were reviewed retrospectively. The prescribed dose was 48 Gy in four fractions at the isocenter (IC) under heterogeneity correction with the Batho power law (BPL). The clinical plans were recalculated with Eclipse (Varian) for the same monitor units under the BPL and anisotropic analytical algorithm (AAA) and with no heterogeneity correction (NC). The dose at the IC, dose that covers 95% of the volume (D95), minimum dose (Min), and mean dose (Mean) of the planning target volume (PTV) were compared under each algorithm and between patients with local lesion control (LC) and LR. The IC doses under NC were significantly lower than those under the BPL and AAA. Under the BPL, the mean PTV D95, Min and Mean were 8.0, 9.4 and 7.4% higher than those under the AAA, and 9.6, 9.2 and 4.6% higher than those under NC, respectively. Under the AAA, all dose-volumetric parameters were significantly lower in T1a patients than in those with T1b and T2a. With a median follow-up of 35.9 months, LR occurred in 18 patients. Between the LC and LR groups, no significant differences were observed for any of the metrics. Even after stratification according to T-stage, no significant difference was observed between LC and LR.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [41] Dosimetric Evaluation of the Impacts of Different Heterogeneity Correction Methods on Target Doses in Stereotactic Body Radiation Therapy for the Lung
    Narabayashi, M.
    Matsuo, Y.
    Mizowaki, T.
    Narita, Y.
    Sato, S.
    Nakamura, M.
    Takayama, K.
    Norihisa, Y.
    Sakanaka, K.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S141 - S142
  • [42] In Silico Ventilation Within the Dose-Volume is Predictive of Lung Function Post-radiation Therapy in Patients with Lung Cancer
    Dong, Yu
    Kumar, H.
    Tawhai, M.
    Veiga, C.
    Szmul, A.
    Landau, D.
    McClelland, J.
    Lao, L.
    Burrowes, K. S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (05) : 1416 - 1431
  • [43] In Silico Ventilation Within the Dose-Volume is Predictive of Lung Function Post-radiation Therapy in Patients with Lung Cancer
    Yu Dong
    H. Kumar
    M. Tawhai
    C. Veiga
    A. Szmul
    D. Landau
    J. McClelland
    L. Lao
    K. S. Burrowes
    Annals of Biomedical Engineering, 2021, 49 : 1416 - 1431
  • [44] To Validate Dose Delivery in Static Field Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Joshi, C. P.
    Garcia, L.
    Olding, T.
    Alexander, K.
    Owen, T.
    Kerr, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [45] Daily Imaging and Dose Deformation for Assessment of Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Jiang, L.
    Foster, R.
    Bzdusek, K.
    Xiong, Y.
    Solberg, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [46] Dosimetric Impact of Four Dose Calculation Algorithms On Stereotactic Body Radiation Therapy for Lung Cancer
    Kusunoki, T.
    Kurooka, M.
    Nonaka, T.
    Yoshino, S.
    Shioiri, K.
    Ide, S.
    Nakayama, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2967 - 2967
  • [47] Stereotactic Body Radiation Therapy in Metastatic Non-Small Cell Lung Cancer: For Oligometastases, Oligoprogression, and Local Control
    Lara, T. R. Merino
    Helou, J.
    Poon, I.
    Sahgal, A.
    Chung, H. T.
    Chu, W.
    Soliman, H.
    Verma, S.
    Cheema, P.
    Cheng, S.
    Khanna, S.
    Erler, D.
    Zhang, L.
    Cheung, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E440 - E441
  • [48] Local Control After Stereotactic Body Radiation Therapy for Stage I Non-Small Cell Lung Cancer
    Lee, Percy
    Loo Jr, Billy W.
    Biswas, Tithi
    Ding, George X.
    El Naqa, Issam M.
    Jackson, Andrew
    Kong, Feng-Ming
    LaCouture, Tamara
    Miften, Moyed
    Solberg, Timothy
    Tome, Wolfgang A.
    Tai, An
    Yorke, Ellen
    Li, X. Allen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 110 (01): : 160 - 171
  • [49] Local control and survival after stereotactic body radiation therapy of early-stage lung cancer patients in Slovenia
    Stanic, Karmen
    But-Hadzic, Jasna
    Zagar, Jan
    Vrankar, Martina
    RADIOLOGY AND ONCOLOGY, 2023, 57 (03) : 389 - 396
  • [50] The Effects of Interplay on Accumulated Dose in High-Dose-Rate Stereotactic Body Radiation Therapy of Lung Cancer
    Watkins, W.
    Song, W. Y.
    Hugo, G. D.
    Weiss, E.
    Siebers, J. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S758 - S758