ICP-MS Analysis of Low-Level Beryllium in Urine

被引:0
|
作者
Riss, Pierre-Emmanuel [1 ]
机构
[1] Bruker Daltonics Inc, Champs Sur Marne, France
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Beryllium levels may be tested in blood using the blood beryllium lymphocyte proliferation test (BeLPT). However, faster and more sensitive analysis may be achieved by measuring beryllium levels in urine by inductively coupled plasma-mass spectrometry (ICP-MS). This article shows that ICP-MS is capable of fast and sensitive detection of urinary beryllium excretion and can deliver extremely low detection capability and simple sample preparation with low sample consumption.
引用
收藏
页码:26 / +
页数:5
相关论文
共 50 条
  • [31] THE ANALYSIS OF GEOLOGICALS USING ICP-MS
    LUNDSTROM, CC
    BOWER, NW
    GLADNEY, ES
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 33 - CHED
  • [32] Analysis and Speciation of Lanthanoides by ICP-MS
    Telgmann, Lena
    Lindner, Uwe
    Lingott, Jana
    Jakubowski, Norbert
    [J]. PHYSICAL SCIENCES REVIEWS, 2016, 1 (11)
  • [33] ICP-MS - THE TECHNIQUE FOR WATER ANALYSIS
    HUTTON, RC
    EATON, AN
    [J]. TRACE ELEMENTS IN NEW ZEALAND : ENVIRONMENTAL, HUMAN AND ANIMAL, 1989, : 287 - 291
  • [34] ICP-MS analysis of environmental plutonium
    Muramatsu, Y
    Yoshida, S
    Tagami, K
    Uchida, S
    Rühm, W
    [J]. PLUTONIUM IN THE ENVIRONMENT, 2001, 1 : 63 - 77
  • [35] Application and quality of ICP-MS analysis
    Prohaska, T
    Stingeder, G
    Nelms, SM
    Quétel, C
    Latkoczy, C
    Hann, S
    Köllensperger, G
    Taylor, P
    [J]. PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 165 - 176
  • [36] RADIONUCLIDE ANALYSIS USING ICP-MS
    GONG, ML
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 72 - ANYL
  • [37] ICP-MS for biological specimen analysis
    Begerow, J
    Dunemann, L
    [J]. NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1996, 44 (7-8): : 739 - 743
  • [38] Low-level analysis of lanthanides in eleven silicate rock reference materials by ICP-MS after group separation using cation-exchange chromotography
    Pin, C
    Joannon, S
    [J]. GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (01): : 43 - 50
  • [39] Analysis of the State of the Art: ICP-MS
    Bush, Laura
    [J]. SPECTROSCOPY, 2015, 30 (06) : 64 - +
  • [40] Potentialities of mass spectrometry (ICP-MS) for actinides determination in urine
    Bouvier-Capely, C
    Ritt, J
    Baglan, N
    Cossonnet, C
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 60 (05) : 629 - 633